Typical industrial projects requiring data loggers
Sourcing Data Loggers spans distinct field applications across smart building air quality, remote agricultural weather stations, rotating machinery vibration monitoring, and cold-chain thermal tracking. Inside a commercial facility, a PoE Ethernet unit such as the ICP DAS CL-223 connects directly to the local network over Modbus or MQTT. On an isolated solar installation without network cabling, the Epever ELOG01-G3 handles local logging over an RS-485 bus.
For field weather observation or irrigation monitoring, a 4 G LTE controller like the Niubol NBL-PH-1 centralizes up to 16 analog or counter channels in its documented configuration. When a logistics shipment or unmanned cabinet requires standalone operation without external power, the Freshliance KEEPER-1 logs locally on a 3.6 V lithium battery with capacity for up to 35,000 readings.
Technical risks of selecting an unsuitable data logger
Overlooking environmental ratings or bus architectures when sourcing Data Loggers frequently leads to costly field replacements. An enclosure rated IP20 to IP44, such as the ICP DAS CL-223 or the Epever ELOG01-G3, is unsuitable for exposed outdoor locations subject to dust and water spray, where an IP65 housing like the Freshliance KEEPER-1 is required.
Electrical and protocol mismatches also stall site commissioning. Missing Modbus, MQTT, RS-232, or RS-485 support prevents direct integration with existing field controllers and industrial sensors. Likewise, specifying a general-purpose voltage unit instead of dedicated IEPE inputs for piezoelectric accelerometers, such as the 3-channel IEPE architecture on the ICP DAS AR-300-T, blocks vibration acquisition unless external signal conditioning is added.
Network interfaces, acquisition channels, and protocol selection criteria
The first selection criterion covers documented communication buses and telemetry uplinks. For remote assets requiring positioning and cellular backhaul, the Niubol 4 G/WIFI/GPS/RS232/RS485 combines a 4 G LTE cellular network, two Ethernet ports, GNSS / GPS, RS-232, Modbus, and MQTT. For multi-sensor telemetry, the Niubol NBL-PH-1 pairs 4 G LTE cellular connectivity with Modbus, RS-232, and RS-485 interfaces.
The second criterion defines channel types and input counts. The Niubol NBL-PH-1 supports up to 16 analog or counter channels in the documented controller configuration for soil and weather measurements. For mechanical diagnostics, the ICP DAS AR-300-T provides 3 IEPE accelerometer channels and 1 thermistor channel. In building environments, the ICP DAS CL-223 integrates 1 Ethernet port, PoE, RS-485, Modbus, and MQTT.
Ingress protection, power autonomy, memory, and footprint criteria
The third criterion evaluates ingress protection and power options. In wet or washdown environments, the Freshliance KEEPER-1 offers an IP65 rating, a 0 to 100%RH humidity range, and a 3.6 V lithium battery. Inside dry electrical cabinets or indoor rooms, IP20 to IP44 units such as the Epever ELOG01-G3 or the ICP DAS CL-223 fit standard mounting requirements, with PoE power available on the latter.
The fourth criterion checks memory depth, sampling intervals, and enclosure dimensions. The Freshliance KEEPER-1 supports a logging interval from 1 minute to 24 hours, up to 6 alarm points, and a maximum memory capacity of 35,000 readings. Where panel space is tight, the compact 71 mm x 67.62 mm x 25.8 mm footprint of the Epever ELOG01-G3 and its PC software configuration simplify cabinet layout.
Quotation workflow, compatibility checks, and full bill of materials supply
Atlas Electronics quotes every list of Data Loggers strictly on quotation to align industrial quantities, exact manufacturer part numbers, and required project accessories. Before confirming an order, the buyer must verify in the manufacturer datasheets that sensor electrical outputs, supply voltage, Modbus or MQTT parameters, logging intervals, and enclosure IP ratings match the target installation environment.
Beyond the primary logger, supply on quotation covers the remaining project bill of materials. This includes standard parallel network cables used with the Epever ELOG01-G3, compatible thermistor and accelerometer probes for the ICP DAS AR-300-T, field sensors wired to the Niubol NBL-PH-1, and cellular edge gateways such as the Niubol 4 G/WIFI/GPS/RS232/RS485 to consolidate multi-site telemetry.
Frequently asked questions
How should a buyer choose between PoE Ethernet and 4 G LTE telemetry for data loggers?
Select a PoE Ethernet model such as the ICP DAS CL-223 when the building already provides local network cabling and switch power. For remote sites without wired infrastructure, specify a 4 G LTE unit like the Niubol NBL-PH-1 or the Niubol 4 G/WIFI/GPS/RS232/RS485.
Which ingress protection rating and power source must be checked for field deployment?
Confirm in the datasheet that the enclosure matches site exposure: an IP20 to IP44 rating such as on the Epever ELOG01-G3 suits dry indoor cabinets, whereas an IP65 housing powered by a 3.6 V lithium battery like the Freshliance KEEPER-1 handles 0 to 100%RH humidity.
What input channels should be verified for vibration or multi-sensor acquisition?
Verify sensor signal compatibility before requesting a quotation: the ICP DAS AR-300-T includes 3 IEPE accelerometer channels and 1 thermistor channel, while the Niubol NBL-PH-1 supports up to 16 analog or counter channels in its documented configuration.
What details should be included in a quotation request to Atlas Electronics?
List the target part numbers, site quantities, required Modbus or MQTT protocols, and supporting accessories such as standard parallel network cables or sensor leads so the supply on quotation covers your complete bill of materials.
Products mentioned
ELOG01-G3
Data Loggers
RS485 data logger for solar systems · Ref. : ELOG01-G3
- RS485
- IP30
Price on request
Fresh Keeper-1
Data Loggers
Reusable USB temperature and humidity data logger · Ref. : KEEPER-1
Price on request
AR-300-T
Data Loggers
3-channel IEPE accelerometer and 1-channel thermistor data logger
Price on request
CL-223-WF
Data Loggers
Air Quality Data Logger PM CO CO2 Ethernet Wi-Fi PoE · Ref. : CL-223
Price on request
TG462
Data Loggers
IoT edge gateway data logger with RS485 and 4G · Ref. : 4G/WIFI/GPS/RS232/RS485
Price on request
NBL-PH-1
Data Loggers
Multi-channel 4G data logger for weather stations · Ref. : NBL-PH-1
- Company Profile
- Company news
Price on request
A project? Our engineers build the solution with you.
Send your requirements: Atlas proposes the architecture, the bill of materials and a quotation, then follows the supply.
Request a quotation
