AR-300-T
3-channel IEPE accelerometer and 1-channel thermistor data logger

- iSN-701-MBase01 CR
- Magnetic Base for iSN-701 series (RoHS)
- Max. Recording time
- 30 m (5kHz)
- PIN No.
- Name
- Support sampling rate
- 125kHz/100kHz/50kHz/20kHz/10kHz/5kHz
3-channel IEPE accelerometer and 1-channel thermistor data logger
ICP DAS accelerometer data logger with 3 IEPE inputs and 1 thermistor input, for acquiring dynamic signals and temperature.
ICP DAS AR-300-T. The AR-300-T is an ICP DAS dynamic signal acquisition module with 3 IEPE inputs and 1 thermistor input, designed for accelerometer data logging.
Main characteristics. The 3 IEPE inputs are sampled simultaneously at up to 125 kHz per channel. Its 3 simultaneous ADCs have 16-bit resolution, and a 3 mA excitation current is built in. The sampling rate is selected from 125 kHz, 100 kHz, 50 kHz, 20 kHz, 10 kHz and 5 kHz.
Storage and recording. The max. recording time is 30 minutes at 5 kHz, on a 4 to 32 GB micro SDHC card. Recording can be triggered by push button, schedule, analog threshold, digital input or software remote trigger.
Compatible accessories. The logger is complemented by CA-TM NTC thermistors and iSN-701 single-axis accelerometers, as well as the iSN-701-MBase01 magnetic base. All components are RoHS compliant.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for AR-300-T, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AR-200 CR | Accelerometer Data Logger Device, 2-ch IEPE Input (RoHS) |
| AR-300-T CR | Accelerometer Data Logger Device, 3-ch IEPE Input, 1-ch Thermistor Input (RoHS) |
| AR-400 CR | Accelerometer Data Logger Device, 4-ch IEPE Input (RoHS) |
| CA-TM-M100-L050P CR | NTC Thermistor, Epoxy Resin to Connector Cable, 5M (-40°C~+80°C) (RoHS) |
| CA-TM-M200-L050P CR | NTC Thermistor, Magnet to Connector Cable, 5M (-40°C~+105°C) (RoHS) |
| CA-TM-P100-L020 CR | NTC Thermistor, Epoxy Resin Cable, 2M (-40°C~+80°C) (RoHS) |
| CA-TM-P100-L050 CR | NTC Thermistor, Epoxy Resin Cable, 5M (-40°C~+80°C) (RoHS) |
| iSN-701-F15-L030 CR | 1-axis accelerometer, Range 80g, Sensitivity 100mV/g, Frequency 15 kHz, includes 300 cm cable (RoHS) |
| iSN-701-F15-L060 CR | 1-axis accelerometer, Range 80g, Sensitivity 100mV/g, Frequency 15 kHz, includes 600 cm cable (RoHS) |
| iSN-701-MBase01 CR | Magnetic Base for iSN-701 series (RoHS) |
| Max. Recording time | 30 m (5kHz) |
| PIN No. | Name |
| PRODUCT SERIES AR-300-T CR | DESCRIPTION Accelerometer Data Logger Device, 3-ch IEPE Input, 1-ch Thermistor Input (RoHS) |
| Support sampling rate | 125kHz/100kHz/50kHz/20kHz/10kHz/5kHz |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for AR-300-T. For a missing document or a specific revision, our experts send it to you.
ICP DAS accelerometer data logger with 3 IEPE inputs and 1 thermistor input, for acquiring dynamic signals and temperature.
| Parameter | Value |
|---|---|
| AR-200 CR | Accelerometer Data Logger Device, 2-ch IEPE Input (RoHS) |
| AR-300-T CR | Accelerometer Data Logger Device, 3-ch IEPE Input, 1-ch Thermistor Input (RoHS) |
| AR-400 CR | Accelerometer Data Logger Device, 4-ch IEPE Input (RoHS) |
| CA-TM-M100-L050P CR | NTC Thermistor, Epoxy Resin to Connector Cable, 5M (-40°C~+80°C) (RoHS) |
| CA-TM-M200-L050P CR | NTC Thermistor, Magnet to Connector Cable, 5M (-40°C~+105°C) (RoHS) |
| CA-TM-P100-L020 CR | NTC Thermistor, Epoxy Resin Cable, 2M (-40°C~+80°C) (RoHS) |
| CA-TM-P100-L050 CR | NTC Thermistor, Epoxy Resin Cable, 5M (-40°C~+80°C) (RoHS) |
| iSN-701-F15-L030 CR | 1-axis accelerometer, Range 80g, Sensitivity 100mV/g, Frequency 15 kHz, includes 300 cm cable (RoHS) |
| iSN-701-F15-L060 CR | 1-axis accelerometer, Range 80g, Sensitivity 100mV/g, Frequency 15 kHz, includes 600 cm cable (RoHS) |
| iSN-701-MBase01 CR | Magnetic Base for iSN-701 series (RoHS) |
| Max. Recording time | 30 m (5kHz) |
| PIN No. | Name |
| PRODUCT SERIES AR-300-T CR | DESCRIPTION Accelerometer Data Logger Device, 3-ch IEPE Input, 1-ch Thermistor Input (RoHS) |
| Support sampling rate | 125kHz/100kHz/50kHz/20kHz/10kHz/5kHz |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
3-channel IEPE accelerometer and 1-channel thermistor data logger

SDLogger - Open Hardware Data Logger

Data Logger Ultrasonic River Flow Meter Open Channel Flowmeters

Weather Station Data Logger Modbus

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | AR-300-T |
| Manufacturer | ICP DAS |
Data Loggers
IoT edge gateway data logger with RS485 and 4G · Ref. : 4G/WIFI/GPS/RS232/RS485
Price on request
Data Loggers
RS485 data logger for solar systems · Ref. : ELOG01-G3
Price on request
Data Loggers
Long-duration data logger with continuous sampling for oscilloscope
Price on request
Data Loggers
Transit-time ultrasonic portable flow meter for liquids
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details