Operational need and target users
This turnkey hardware package is designed for industrial plant operators, system integrators, and maintenance teams seeking a ready-to-deploy monitoring and telemetry solution. It removes the complexity of selecting and interfacing disparate components by providing a pre-validated hardware set ready for cabinet integration.
The package meets requirements for continuous remote machinery monitoring, delivering reliable transmission of operational alarms and metrics to central supervisory platforms.
Base configuration composition
The standard baseline configuration incorporates all components necessary for the acquisition and transmission loop.
The Grandstream GSC3506 (Paging and Public Address Systems) addresses these field integration requirements and connects seamlessly to industrial networks.
The Sunell SN-PA1C04-M-15 (Paging and Public Address Systems) addresses these field integration requirements and connects seamlessly to industrial networks.
The Sunell SN-PA1C04-M-30 (Paging and Public Address Systems) addresses these field integration requirements and connects seamlessly to industrial networks.
The Grandstream GSC3510 (Paging and Public Address Systems) addresses these field integration requirements and connects seamlessly to industrial networks.
Each component has been selected for hardware durability, efficient power consumption, and immediate compatibility with standard industrial protocols.
Hardware interfaces and connectivity
Interconnection utilizes proven wired interfaces (two-wire RS-485 serial buses, industrial RJ-45 Ethernet ports) ensuring electrical isolation between measurement instruments and the communication gateway.
The edge gateway handles frame conversion from Modbus RTU to Modbus TCP or MQTT, enabling seamless integration into modern SCADA supervisors or industrial cloud dashboards.
Expansion options and alternatives
Depending on specific site constraints, several modular options can be incorporated: adding a 4G or 5G cellular gateway for remote locations lacking wired infrastructure, distributed input/output modules, or high-gain external antennas.
Alternative power options for 12VDC or 48VDC operation can also be configured to match existing cabinet power sources.
Customer prerequisites and site scope
To finalize on-site commissioning, the customer supplies the protective enclosure (electrical cabinet or modular wall box), primary AC or DC power feed, and where applicable an activated SIM card from the chosen telecommunications carrier.
Physical DIN rail mounting and power cable terminations are performed by site technicians or electrical contracting partners.
Project workflow and commissioning
The project initiates when your operational requirements are reviewed by our engineering desk. Our team confirms electrical sizing and prepares recommended wiring diagrams.
Hardware is staged in our technical facility, labeled, and dispatched in protective packaging. Our specialists remain available to assist remotely during on-site commissioning and acceptance testing.
Quotation and Atlas ordering
Every packaged solution receives a customized formal quotation based on required quantities and selected modular expansions. Atlas commits to supplying genuine, industrial-grade equipment.
Contact our technical representatives today to receive a detailed bill of materials quotation.
Step by step
Inventory and requirements audit
List all field devices to connect, their communication protocols, and site environmental constraints to prepare integration.
Hardware selection and sizing
Validate the electrical schematic, confirm power budgets, and select appropriate gateways and power supplies meeting production needs.
Cabinet mounting and wiring
Mount modules onto TS-35 DIN rails, connect regulated 24VDC power feeds, and terminate communication buses according to EMC guidelines.
Software configuration and addressing
Configure static IP addresses, serial communication parameters, and network security credentials inside device firmware.
Acceptance testing and commissioning
Verify live telemetry reception, test communication interruption recovery, and validate overall operation across the operational site.
Bill of materials
Catalogue products that can fill each role. Atlas Electronics quotes the complete bill of materials for your project; you check each datasheet before ordering.
Paging and speakers
Hardware role for Paging and speakers functionality.
GSC3506 V2
Paging and Public Address Systems
HD SIP multicast paging speaker · Ref. : GSC3506
Price on request
SN-PA1C04-M-15
Paging and Public Address Systems
15 W IP ceiling speaker with built-in microphone · Ref. : SN-PA1C04-M-15
- 15 W
- 100 Hz to 20 kHz
Price on request
SN-PA1C04-M-30
Paging and Public Address Systems
30 W IP ceiling speaker with built-in microphone · Ref. : SN-PA1C04-M-30
Price on request
GSC3510
Paging and Public Address Systems
Full-duplex SIP intercom speaker with directional microphones · Ref. : GSC3510
Price on request
Intercoms and phones
Hardware role for Intercoms and phones functionality.
GRP2612
IP Phones
Professional 4-line SIP IP phone with HD audio · Ref. : GRP2612
Price on request
GRP2613
IP Phones
6-line professional IP phone with 2.8-inch color TFT display · Ref. : GRP2613
Price on request
GRP2610
IP Phones
2-line SIP IP phone with 2.4-inch colour LCD display · Ref. : GRP2610
Price on request
G500
IP Phones
Desk IP Phone with 5-inch Colour TFT Screen · Ref. : G500
Price on request
Frequently asked questions
How can I obtain a quotation for this hardware?
Submit your bill of materials or operational requirements to our engineers. Atlas provides a comprehensive quotation covering all hardware and support.
Is this hardware compliant with industrial standards?
Yes, all selected devices meet rigorous industrial standards for electromagnetic compatibility, temperature resilience, and electrical isolation.
Does Atlas provide integration support?
Our application engineers verify the technical coherence of your hardware architecture and advise you on selecting necessary wiring accessories.
What prerequisites are required for commissioning?
You must provide a regulated power source matching device specifications and establish an addressing plan for devices on the local network.
A project? Our engineers build the solution with you.
Send your requirements: Atlas proposes the architecture, the bill of materials and a quotation, then follows the supply.
Request a quotation