BNT017-30-KTA – Three Phase PV String Inverter 17-30 kW Low-voltage

Three Phase PV String Inverter 17-30 kW Low-voltage

Grid-Tied Solar Inverters

Manufacturer part number
INVERTER17
Manufacturer
Afore

Afore three-phase PV string inverter from 17 to 30 kW for commercial solar installations and power plants. It converts DC power from solar panels into three-phase AC grid power.

Product overview

Overview. The Afore BNT017-30-KTA is a transformerless three-phase PV string inverter from the low-voltage series, designed for commercial photovoltaic installations and power plants. It features an anodized aluminum enclosure, IP 65 protection and intelligent fan cooling.

Main characteristics. It has two MPPT trackers and five PV strings, with an MPPT voltage range of 200 to 700 V and a full power voltage range of 310 to 600 V. The maximum input current is 38 A per MPPT and the maximum short-circuit current is 48 A per MPPT. Maximum efficiency reaches 98.40%, with a Euro efficiency of 98.00%. The power factor is adjustable from 0.8 leading to 0.8 lagging, with a default value of 1. Output current THD is below 3%, and night power consumption is below 1 W.

Output and grid. The output is 3P+N+PE or 3P+PE, 133/220 or 230 V, at 50 or 60 Hz. The grid voltage range is 180 to 260 Vac and the grid frequency range is 45 to 55 Hz or 55 to 65 Hz according to local standard. Grid-connection standards include IEEE1547, EN50549, VDE4105, VDE0126, RD1699, AS4777.2, G98/G99 and IEC61727.

Connectivity. Communication interfaces are RS485, WiFi and wired Ethernet, with GPRS optional. Modbus support is available for monitoring by a PLC or supervision system, and configuration is done via WiFi.

Power and environment. The inverter operates from -25 to +60 °C, with a relative humidity range of 0 to 100%. Its dimensions are 450 x 485 x 210 mm. It integrates a DC switch, AC overcurrent, overvoltage and short-circuit protection, residual current detection, PV insulation resistance detection, anti-islanding protection and type II surge protection.

Integration. DC input connectors are MC4 type. Safety standards are IEC 60068, UL1741 and EN62109, and EMC standards are EN/IEC 61000-6-2 and 61000-6-3.