BNT036-60KTL – Three-phase PV string inverter 36-60 kW

Three-phase PV string inverter 36-60 kW

Grid-Tied Solar Inverters

Manufacturer part number
THREE-PHASE-36-60KW
Manufacturer
Afore

Three-phase transformerless string solar inverter from 36 to 60 kW for commercial PV installations and power plants, with 3 MPPT trackers and 6 string inputs.

Product overview

Overview. The Afore BNT036-60KTL is a three-phase PV string inverter (Grid-Tied Solar Inverter) designed for commercial PV installations and power plants, in a power range from 36 to 60 kW.

Main characteristics. Maximum efficiency of 98.65% and Euro efficiency of 98.20%. Three MPPT trackers with six string inputs, MPPT voltage range of 200 to 1000 V and MPPT full power voltage range of 500 to 850 V. Maximum input current of 38 A per MPPT and maximum short-circuit current of 48 A per MPPT. Transformerless topology, adjustable power factor from 0.8 leading to 0.8 lagging, output current THD below 3%. MC4 input connectors and integrated DC switch. Night power consumption below 1 W.

Interfaces and connectivity. RS485, WiFi, wired Ethernet and optional GPRS communication. Smart IV Curve Scanning function and PV insulation resistance detection.

Power and environment. Three-phase output 3P+N+PE / 3P+PE 230/400 V, nominal frequency 50/60 Hz, grid voltage range 260 to 519 V and grid frequency range 45-55 Hz / 55-65 Hz according to local standard. Ambient temperature range -25 to 60 °C, humidity 0 to 100%, maximum operating altitude 4000 m, protection degree IP65. Anodized aluminum enclosure and intelligent fan cooling. Dimensions 710 x 470 x 236 mm.

Protections. AC overcurrent, overvoltage and short-circuit protection, anti-islanding protection, over-temperature protection, residual current detection, PV reverse polarity protection and integrated Type II surge protection. Optional quick arc fault circuit interruption.

Standards. Grid connection compliance with IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 and 16150, AS4777.2, NB/T32004, G98/G99 and IEC61727. Safety standards IEC 60068, UL1741 and EN62109. EMC standards EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11 and EN61000-3-12.

Uses and integration. Intended for commercial PV installations and photovoltaic power plants. The RS485 link allows integration into a supervision system, and WiFi or Ethernet communication enables system status monitoring via the manufacturer's online portal or application.