BGA-206A – Blue-green algae fluorescence sensor with RS485 output

Blue-green algae fluorescence sensor with RS485 output

Water Quality Analyzers and Probes

  • 0-300.0 Kcells/mL
  • ±3%
  • -15~65℃
Manufacturer part number
BGA-206A
Manufacturer
Apure
Measuring Range
0-300.0 Kcells/mL
Accuracy
±3%

Apure BGA-206A submersible sensor that measures fluorescence of a cyanobacterial pigment channel, with an isolated RS485 digital output for continuous monitoring of an aquatic environment.

Product overview

Overview. The Apure BGA-206A is a blue-green algae (cyanobacteria) fluorescence sensor intended for monitoring cell concentration in water. A light source excites the target pigment and the detector measures the fluorescence emitted at a longer wavelength. The optical response depends on pigment content, species, physiology and sample conditions.

Main characteristics. Measuring range of 0 to 300.0 Kcells/mL, resolution of 0.1 Kcells/mL (100 cells/mL), accuracy of ±3%, operating temperature from -15 to 65 °C and minimum operating temperature of -10 °C. Kcells/mL means thousands of cells per millilitre; the indication is a calibrated estimate and not a direct biological count.

Interfaces and connectivity. Isolated RS485 digital signal output for integration into a supervisory system. The standard cable is 5 metres long, with other lengths available on request. The Φ6 mm outer diameter cable has a degree of corrosion resistance and can remain immersed, including in sea water. Wire colours are red (power 12 to 24 VDC), black (ground GND), blue (485A), white (485B) and bare (shield). Check the wiring before power-up, and obtain the register map, units and serial settings from the manufacturer.

Typical uses. Monitoring of cyanobacteria and targeted control sampling. The measurement does not quantify cyanotoxins, which require a dedicated test. A cyanobacterial pigment sensor is not a universal sensor for all green algae, red algae or marine microalgae. Establish a quantitative relationship with laboratory cell enumeration or pigment analysis, then set cleaning and verification intervals.

Integration. The signal can be affected by turbidity, coloured dissolved substances, fouling and light conditions. The product is available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Accuracy: ±3%
  • Cable Length: 5 meters, other lengths can be customized
  • Digital Output: Isolated protection RS485 signal output
  • Measuring Range: 0-300.0 Kcells/mL
  • Model: BGA-206A
  • Resolution: 0.1 Kcells/mL(100 cells/mL)