TN-300
Online total nitrogen analyzer with optical measurement

- Measuring Range
- 0~5mg/L
- Accuracy
- 0.05mg/L or ±10%
- Digital Output
- RS485 Modbus RTU
- Listed operating conditions
- 0~50°C, 0~1Bar
Online total nitrogen analyzer with optical measurement
The Apure TN-300 is an online total nitrogen analyzer for water monitoring, with a 0 to 5 mg/L measuring range and an RS485 Modbus RTU output.
Overview. The Apure TN-300 is an online total nitrogen analyzer for water monitoring. It measures total nitrogen over a range of 0 to 5 mg/L, with a stated accuracy of 0.05 mg/L or ±10%. The manufacturer advises confirming the supplied analytical method, sample fraction and calibration before interpreting the result as total nitrogen in the intended water body.
Main characteristics. The measuring range is 0 to 5 mg/L, with an accuracy of 0.05 mg/L or ±10%. The manufacturer indicates quick installation and long life. Total nitrogen includes the inorganic and organic nitrogen forms in the sample, expressed on a nitrogen mass basis; a measurement limited to nitrate, ammonium or TKN is not a complete total nitrogen determination.
Interfaces and connectivity. RS485 Modbus RTU digital output, compatible with Modbus connection. The manufacturer states that wiring, register map, nitrogen units and timing and status information must be obtained from the manufacturer.
Operating conditions. Listed operating conditions: 0 to 50 °C, 0 to 1 bar. Particles, organic matter and salinity of the sample should be assessed, as they can influence the result.
Typical uses. Online monitoring of total nitrogen in water, with a Modbus output allowing integration into a supervision system.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for TN-300, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | 0.05mg/L or ±10% |
| Comparison with nitrate, nitrite, ammonia or TKN | Match the analytical definitions and units; a single species or TKN alone is not interchangeable with total nitrogen. |
| Digital Output | RS485 Modbus RTU |
| Dissolved nitrogen | The filtered-water fraction and the method for the relevant dissolved nitrogen forms must be specified. |
| Listed operating conditions | 0~50°C, 0~1Bar |
| Measuring Range | 0~5mg/L |
| Model | TN-300 |
| Required result | What must be established |
| Total nitrogen in whole water | The method must account for dissolved and particulate nitrogen. Suspended material and incomplete conversion can bias an apparent total result. |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for TN-300. For a missing document or a specific revision, our experts send it to you.
The Apure TN-300 is an online total nitrogen analyzer for water monitoring, with a 0 to 5 mg/L measuring range and an RS485 Modbus RTU output.
| Parameter | Value |
|---|---|
| Accuracy | 0.05mg/L or ±10% |
| Comparison with nitrate, nitrite, ammonia or TKN | Match the analytical definitions and units; a single species or TKN alone is not interchangeable with total nitrogen. |
| Digital Output | RS485 Modbus RTU |
| Dissolved nitrogen | The filtered-water fraction and the method for the relevant dissolved nitrogen forms must be specified. |
| Listed operating conditions | 0~50°C, 0~1Bar |
| Measuring Range | 0~5mg/L |
| Model | TN-300 |
| Required result | What must be established |
| Total nitrogen in whole water | The method must account for dissolved and particulate nitrogen. Suspended material and incomplete conversion can bias an apparent total result. |
Answers to the questions that the recorded characteristics of TN-300 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Digital Output": RS485 Modbus RTU.
Yes — recorded under "Total nitrogen in whole water": The method must account for dissolved and particulate nitrogen. Suspended material and incomplete conversion can bias an apparent total result..
Yes — recorded under "Digital Output": RS485 Modbus RTU.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Online total nitrogen analyzer with optical measurement

Total Phosphorus Analyzer

BOD Sensor

Potassium Ion Selective Electrode

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | TN-300 |
| Manufacturer | Apure |
pH and Conductivity Analyzers
RS485 Modbus Dissolved Oxygen Sensor, Fluorescence Method
Price on request
pH and Conductivity Analyzers
Online UV fluorescence BOD sensor, reagent-free · Ref. : WQ-BOD-4S
Price on request
pH and Conductivity Analyzers
Portable ORP analyzer with digital electrode and touch screen
Price on request
pH and Conductivity Analyzers
Multiparameter Water Quality Sensor · Ref. : KPS-400
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details