TS-620 – Online turbidity meter with optical sensor and 4-20 mA output

Online turbidity meter with optical sensor and 4-20 mA output

Turbidity Sensors

  • 242×184×135mm
  • Precision
  • 0-50℃
  • ±1%FS
Manufacturer part number
TS-620
Manufacturer
Apure
Dimensions
242×184×135mm
Medium temperature
0-50℃

The TS-620 is an Apure online turbidity meter used with a matched optical sensor for turbidity monitoring in water and wastewater.

Product overview

Overview. The Apure TS-620 is an online turbidity meter designed for use with a matched optical sensor to monitor turbidity in water and wastewater. Turbidity is an optical measurement influenced by particle properties and the measuring arrangement; it is not a direct measurement of suspended-solids mass.

Main characteristics. Two sensors are offered as separately listed options: the TD-400, with a range of 1 to 100.00 NTU and a resolution of 0.01 NTU, and the TD-5000, with a range of 20 to 5000 NTU and a resolution of 0.1 NTU. Precision is ±1%FS. The medium temperature must be between 0 and 50 °C, and environmental relative humidity must be less than or equal to 85%. The minimum operating temperature is 0 °C or higher. Dimensions are 242×184×135 mm.

Interfaces and connectivity. The TS-620 provides one isolated 4-20 mA signal output and alarm relays; the exact output configuration must be confirmed on the terminal drawing and relay list of the ordered controller. An RS485 port is mentioned in the manufacturer documentation for the communication options and should be checked against the communication specification before integration.

Typical uses. Continuous turbidity monitoring in water and wastewater treatment installations, with the 4-20 mA signal transmitted to a supervision system or PLC. The optical sensor is installed in representative water, away from bubbles and deposits. Two-point calibration follows the documented procedure, using the specified references.

Integration. Confirm the ordered sensor/controller pair, the enabled functions and the mapping of outputs to the control system before commissioning. Keep a separate record of verification results and maintenance.

See all specifications

Highlights

  • Dimensions: 242×184×135mm
  • Control interface: 4-Relay(high-low point trigger)
  • Electrode measurement range: TD-400: 1-100.00ntu TD-5000: 20-5000ntu
  • Electrode measurement range — Resolution: Precision
  • Environmental humidity: relative humidity is less than or equal to 85%
  • Medium temperature: 0-50℃

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Turbidity Sensors
Request a quote