Single-phase electronic energy meter on a 35 mm DIN rail that measures and displays grid parameters and sends them via RS485 to a solar inverter in a zero-export system.
Limited working temperature range — -40 ℃ ~+70 ℃ — 25 ℃ ~+75 ℃/
Regulated working temperature range — -25 ℃ ~+55 ℃ — -10 ℃ ~+45 ℃-25 ℃ ~+55 ℃
Communication interfaceRS485
AC power supply input voltage — 176-264V — 100-265V — 176-276V — 85-480V85-275V / 120-380V
Max. direct current measurement (A) — 60 — 80 — 1001-9999A (with CT)
Deye DSU666/SDM230-M, single-phase electronic energy meter — the Deye DSU666/SDM230-M is a single-phase energy meter for DIN rail mounting, designed to monitor and display electrical grid parameters: voltage, current, frequency and energy.
Measurement. it provides active power measurement at Class 1 and reactive power measurement at Class 2, metering positive and reverse active power and four-quadrant reactive power. Direct measurement covers 20 to 550 V between phase and neutral, and direct current measurement ranges from 1 to 9999 A with a current transformer.
Display and communication. a local LCD display allows on-site reading, and the RS485 interface transfers data to a solar inverter, notably in a zero-export system.
Power and environment. the power supply accepts 85 to 275 V or 120 to 380 V, with maximum consumption of 2 W / 10 VA. The regulated working temperature range is -25 °C to +55 °C, with humidity from 0 to 95 %, non-condensing. The housing has an IP51 degree of protection and weighs 0.29 kg.
Typical uses. this meter is suited to measuring and displaying grid parameters in zero-export systems, as well as in photovoltaic power plant installations where energy monitoring is required.
Integration. mounting is on a DIN rail. The product is available on quotation from Atlas Electronics.
Single-phase electronic energy meter on a 35 mm DIN rail that measures and displays grid parameters and sends them via RS485 to a solar inverter in a zero-export system.
Limited working temperature range — -40 ℃ ~+70 ℃ — 25 ℃ ~+75 ℃/
Regulated working temperature range — -25 ℃ ~+55 ℃ — -10 ℃ ~+45 ℃-25 ℃ ~+55 ℃
Communication interfaceRS485
AC power supply input voltage — 176-264V — 100-265V — 176-276V — 85-480V85-275V / 120-380V
Max. direct current measurement (A) — 60 — 80 — 1001-9999A (with CT)
2. Datasheet extract (recorded values)
Parameter
Value
AC power supply input frequency — 50/60Hz — 50Hz
50/60Hz ±2%
AC power supply input voltage — 176-264V — 100-265V — 176-276V — 85-480V
85-275V / 120-380V
Active power
Class1
Communication interface
RS485
Degree of protection
IP51
Dimenstions (L/H/W) in mm — 36×85×66 — 100×72×66 — 36×99×63 — 72×100×66
72×94.5×65
Direct measurement between phase and neutral — 176~264V — 100-265V — 176~276V — 85~480V
20-550V
Direct Voltage measurement between phases — / — 176-458V — / — 147-480V
50-950V
Display
LCD
Humidity — ≤75%
0~95%, non-Condensing
Limited working temperature range — -40 ℃ ~+70 ℃ — 25 ℃ ~+75 ℃
/
Max. direct current measurement (A) — 60 — 80 — 100
1-9999A (with CT)
Mounting Options
DIN Rail
Power consumption — ≤1W / 8VA — ≤1.5W / 6VA
≤2W / 10VA
Reactive power
Class2
Regulated working temperature range — -25 ℃ ~+55 ℃ — -10 ℃ ~+45 ℃
-25 ℃ ~+55 ℃
Weight (kg) — 0.21 — 0.44 — 0.21 — 0.42
0.29
Applications and use cases
Architectures in which ENERGY-METER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for ENERGY-METER and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productDeye
ENERGY-METER
Single-phase DIN rail energy meter with RS485 output
Limited working temperature range — -40 ℃ ~+70 ℃ — 25 ℃ ~+75 ℃
/
Regulated working temperature range — -25 ℃ ~+55 ℃ — -10 ℃ ~+45 ℃
-25 ℃ ~+55 ℃
Communication interface
RS485
AC power supply input voltage — 176-264V — 100-265V — 176-276V — 85-480V
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details