SUN-5/6/8/10/12K-SG05LP2-US-SM2/SM3 – Split-phase hybrid solar inverter 5-12 kW, 3 MPPT, low-voltage battery

Split-phase hybrid solar inverter 5-12 kW, 3 MPPT, low-voltage battery

Grid-Tied Solar Inverters

  • RS485/RS232/CAN
  • <0.5%ln
  • 60+60+60
  • 32+32+32
Manufacturer part number
SM3
Manufacturer
Deye
Operating Temperature Range
-40 to +60℃, >45℃ Derating
Communication interface
RS485/RS232/CAN

Deye split-phase hybrid inverter rated 5 to 12 kW, combining photovoltaic input and low-voltage battery management for solar installations with energy storage.

Product overview

Deye SUN-5/6/8/10/12K-SG05LP2-US-SM2/SM3. This split-phase hybrid inverter from manufacturer Deye covers ratings from 5 to 12 kW and manages both photovoltaic input and battery storage.

Main characteristics. Three MPPT inputs (3 MPPT, 2+2+2 strings), MPPT voltage range of 150 to 425 V, maximum efficiency of 97.6% and Euro efficiency of 96.5%. The rated AC output current is 41.7 A for a 120/240 V or 120/208 V grid at 60 Hz. Peak power in off-grid mode reaches 2 times the rated power for 10 s.

Battery and interfaces. Compatible with lead-acid or lithium-ion batteries over a 40 to 60 V range, with charging self-adapted to the BMS for lithium-ion. Communication via RS485, RS232 or CAN, LCD display.

Protection and compliance. Integrated protection against DC reverse polarity, AC overcurrent and overvoltage, AC short circuit and anti-islanding, with insulation impedance and residual current detection. Arc fault circuit interrupter (AFCI) optional. Compliant with IEEE 1547.1, SRD V2.0, FCC and UL 1741. Ingress protection TYPE 3R.

Environment and installation. Operating range -40 to +60 °C with derating above 45 °C, intelligent air cooling, noise below 45 dB, permissible altitude up to 3000 m. Dimensions 386×606.5×240 mm, weight 29.2 kg.

Typical uses. Residential or commercial photovoltaic installations with battery storage, supervised through the communication port. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Battery Type: Lead-acid or Lithium-ion
  • Battery Voltage Range (V): 40-60
  • Cabinet Size (WxHxD mm): 386×606.5×240 (Excluding Connectors and Brackets)
  • Charging Strategy for Li-ion Battery: Self-adaption to BMS
  • Communication interface: RS485/RS232/CAN
  • DC Injection Current: <0.5%ln

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -40 to +60℃, >45℃ Derating — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.