SEN0233 – Air Quality Sensor for PM2.5, Temperature and Humidity

Air Quality Sensor for PM2.5, Temperature and Humidity

Particulate Matter Sensors

  • -40~80℃
  • -10~50℃
  • 0~99%
  • 0~99℃
Manufacturer part number
SEN0233
Manufacturer
DFRobot
Storage Temperature Range
-40~80℃
Working Temperature Range
-10~50℃

DFRobot SEN0233 module combining PM1.0, PM2.5 and PM10 particulate measurement by laser scattering with temperature and humidity sensing, for integration into air quality monitoring instruments.

Product overview

Overview. The DFRobot SEN0233 is an air quality monitor that measures PM10, PM2.5 and PM1.0 particle concentrations together with temperature and humidity in a single module. It works with Arduino and STM32 devices.

Particle measurement. Based on laser scattering, the sensor continuously counts suspended particles of various sizes per unit volume of air, then converts this distribution into mass concentration. Measurement ranges are 0.3 to 1.0 μm, 1.0 to 2.5 μm and 2.5 to 10 μm, with a mass concentration resolution of 1 μg/m³. Particle counting efficiency is 50% at 0.3 μm and 98% at 0.5 μm and above.

Temperature and humidity. An integrated sensing chip measures temperature from 0 to 99 °C with ±0.5 °C accuracy and 0.1 °C resolution, and relative humidity from 0 to 99% with ±2% accuracy and 0.1% resolution.

Interfaces and power. Data frames are output via UART, with logic levels L below 0.8 V and H above 2.7 V and a maximum level voltage of 3.3 V. DC supply is typically 5 V, within 4.5 V to 5.5 V, with a working current of 100 mA or less and a standby current of 200 mA or less.

Environment and reliability. The module operates between -10 and 50 °C and between 0 and 99% humidity, and can be stored between -40 and 80 °C. Its mean time between failures is 3 years or more. It measures 50 × 38 × 21 mm and its comprehensive response time is 10 s or less.

Integration. The sensor is designed to be embedded in air quality monitoring instruments and equipment. The metal shell is connected to the internal power ground and must not be short-circuited with other board circuits or the chassis. When used with purifiers or fixed detection equipment, the documentation recommends mounting it more than 20 cm above the ground and isolating it from purifier air ducts.

See all specifications

Highlights

  • Comprehensive Response Time: ≤10s
  • Data Interface Level: L<0.8V, H>2.7V, maximum level voltage 3.3V
  • DC Supply Voltage: Typ: 5V Min: 4.5V Max: 5.5V
  • Humidity Measurement Accuracy: ±2%
  • Humidity Measurement Range: 0~99%
  • Humidity Measurement Resolution: 0.1%

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Power: plan for a supply compatible with Typ: 5V Min: 4.5V Max: 5.5V.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.