SGP40 volatile organic compound sensor in a breakout module, providing an air quality index from 0 to 500 for indoor air monitoring and ventilation control.
Operating temperature-10°C to 50°C
Measurement Range0-1000ppm (ethanol equivalent)
InterfaceI2C (0x59 address)
Dimensions18×11.5mm
Response time2 seconds
Humidity Compensation0-90% RH
Product overview
Overview. The DFRobot SGP40 sensor, ref. SEN0392, is a volatile organic compound (VOC) sensor in an 18 × 11.5 mm breakout module. It directly outputs a VOC index from 0 to 500, corresponding to an ethanol-equivalent concentration of 0 to 1000 ppm, using the standardized algorithm built into the sensor.
Main characteristics. The response time is 2 seconds and the sensor is operational 10 seconds after power-up. It operates from -10 °C to 50 °C and compensates for relative humidity from 0 to 90% RH. Operating current is 2.6 mA.
Interfaces and connectivity. The module communicates over I2C at address 0x59 and connects through the supplied 2.54 mm single-row 4-pin connector.
Power and environment. The supply voltage is 3.3 V to 5 V DC.
Typical uses. Indoor air quality monitoring, ventilation control in kitchens, offices and laboratories, and performance optimization of air purifiers.
Integration. The module is compatible with Arduino and Raspberry Pi and includes C and Python libraries. It is compatible with Home Assistant and MQTT and can be stacked with other Fermion sensors.
SGP40 volatile organic compound sensor in a breakout module, providing an air quality index from 0 to 500 for indoor air monitoring and ventilation control.
Operating temperature-10°C to 50°C
Measurement Range0-1000ppm (ethanol equivalent)
InterfaceI2C (0x59 address)
Dimensions18×11.5mm
Response time2 seconds
2. Datasheet extract (recorded values)
Parameter
Value
Dimensions
18×11.5mm
Response time
2 seconds
Operating temperature
-10°C to 50°C
Fermion
SGP40 VOC Air Quality Sensor - Smart IAQ Monitoring (Breakout)
Humidity Compensation
0-90% RH
Interface
I2C (0x59 address)
Measurement Range
0-1000ppm (ethanol equivalent)
Power
3.3-5V DC, 2.6mA operating current
VOC Index
0-500 (standardized air quality score)
Warm-Up
10 seconds to operational
Integration
Points to check before using SEN0392 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -10°C to 50°C — check it against the installation environment.
Power and communication
Power
3.3-5V DC, 2.6mA operating current
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -10°C to 50°C — check it against the installation environment.
Applications and use cases
Architectures in which SEN0392 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for SEN0392 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details