SEN0568
H2S Gas Sensor, MEMS, 0.5-50 ppm Detection Range

- Operating Temperature
- -10-50℃
- Detection range
- 0.5-50ppm
- Operating Current
- <20mA
- Dimension
- 13×13 x 2.5mm/0.0.51×0.51x0.1”
H2S Gas Sensor, MEMS, 0.5-50 ppm Detection Range
Compact MEMS hydrogen sulfide (H2S) and benzene gas sensor with analog voltage output, intended for H2S detection in toilets, sewers and waste treatment stations.
DFRobot SEN0568 H2S sensor. The DFRobot SEN0568 is a MEMS hydrogen sulfide (H2S) gas sensor, supplied as a breakout board, for detecting H2S in a range of 0.5 to 50 ppm.
Main characteristics. The sensor measures 13 × 13 × 2.5 mm and draws less than 20 mA in operation. Its sensitivity is defined by the ratio R0 (in air) / Rs (in 50 ppm H2S) greater than or equal to 3. It is a qualitative sensor: for quantitative measurements, the manufacturer refers to the Gravity factory-calibrated electrochemical gas sensor series.
Interfaces and output. The output is an analog voltage signal. The sensor operates from 3.3 to 5 V. It also detects benzene.
Power and environment. Operating temperature from -10 to 50 °C and humidity from 15 to 90 %RH, non-condensing. Stated lifespan of 5 years or more in air.
Typical uses. Hydrogen sulfide detection in toilets, sewers and garbage stations, by integration into portable detectors or IoT safety systems.
Integration. Remove the protective film before use. Avoid exposure to volatile silicon compound vapours, high concentrations of corrosive gases, water and condensation. The manufacturer advises against using this module in systems involving personal safety.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for SEN0568, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Detection range | 0.5-50ppm |
| Dimension | 13×13 x 2.5mm/0.0.51×0.51x0.1” |
| Fermion | H2S Gas Sensor – Hydrogen Sulfide Detector (Breakout, 0.5-50ppm, MEMS, Low Power) |
| Gas detected | Hydrogen Sulfide (H2S), Benzene |
| Lifespan | ≥5 years (in air) |
| Operating Current | <20mA |
| Operating Humidity | 15-90%RH (non-condensing) |
| Operating Temperature | -10-50℃ |
| Operating Voltage | 3.3-5V |
| Output signal | Analog voltage |
| Sensitivity | R0 (in air)/Rs (in 50ppm H2S) ≥ 3 |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for SEN0568. For a missing document or a specific revision, our experts send it to you.
Compact MEMS hydrogen sulfide (H2S) and benzene gas sensor with analog voltage output, intended for H2S detection in toilets, sewers and waste treatment stations.
| Parameter | Value |
|---|---|
| Detection range | 0.5-50ppm |
| Dimension | 13×13 x 2.5mm/0.0.51×0.51x0.1” |
| Fermion | H2S Gas Sensor – Hydrogen Sulfide Detector (Breakout, 0.5-50ppm, MEMS, Low Power) |
| Gas detected | Hydrogen Sulfide (H2S), Benzene |
| Lifespan | ≥5 years (in air) |
| Operating Current | <20mA |
| Operating Humidity | 15-90%RH (non-condensing) |
| Operating Temperature | -10-50℃ |
| Operating Voltage | 3.3-5V |
| Output signal | Analog voltage |
| Sensitivity | R0 (in air)/Rs (in 50ppm H2S) ≥ 3 |
Points to check before using SEN0568 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Operating Current | <20mA |
| Operating Voltage | 3.3-5V |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of SEN0568 can answer. A question is not asked when nothing is recorded to answer it.
-10-50℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
H2S Gas Sensor, MEMS, 0.5-50 ppm Detection Range

Industrial-grade MODBUS RS485 H2S Sensor - with Waterproof Aviation Connector

H2S-Dev V1.2 Basic

Eddy Sensor - H…

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | SEN0568 |
| Manufacturer | DFRobot |
H2S Sensors
Industrial H2S Sensor RS485 Modbus RTU with Waterproof Connector · Ref. : 101990863
Price on request
H2S Sensors
LoRaWAN washroom odor sensor with NH3 and H2S sensing · Ref. : LORAWAN-WASHROOM-ODOR-SENSOR
Price on request
H2S Sensors
Electrochemical hydrogen sulfide H2S gas sensor · Ref. : ME3-H2S
Price on request
H2S Sensors
Hydrogen sulfide gas transmitter sensor · Ref. : RS-H2S
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details