S-H2S-01 – Industrial H2S Sensor RS485 Modbus RTU with Waterproof Connector

Industrial H2S Sensor RS485 Modbus RTU with Waterproof Connector

H2S Sensors

  • 25mW @ 5V DC
  • Resolution
  • 2 meters
  • 0.1 ppm
Manufacturer part number
101990863
Manufacturer
Seeed Studio
Power consumption
25mW @ 5V DC
Ambient Pressure
Atmospheric pressure ±10%.

Industrial hydrogen sulfide (H2S) sensor that also measures air temperature and humidity, with RS485 Modbus RTU output and a waterproof aviation connector.

Product overview

Seeed Studio S-H2S-01 is an industrial hydrogen sulfide (H2S) sensor with MODBUS-RTU RS485 output, designed for air quality monitoring in industrial environments. — Measurement — The sensor measures H2S concentration from 0 to 100 ppm, with a minimum detection limit of 1 ppm and an accuracy of ± 5% F.S. It also measures temperature from -40 to 85 °C (± 0.2 °C) and humidity from 10 to 95 %RH (± 2 %RH), with a resolution of 0.1 °C and 0.1 %RH. — Interfaces and connectivity — The MODBUS-RTU RS485 protocol allows direct integration into a supervision system or a PLC. The 2-metre cable ends in a waterproof aviation connector. — Power and environment — The sensor operates from 3.3 to 5.5 V DC (5 V recommended), with a power consumption of 25 mW at 5 V DC. The protection rating is IP65. The operating temperature range is -40 °C to 55 °C, with 15 to 95 %RH humidity (non-condensation) and atmospheric pressure ±10%. — Features — Fast-response, fast return-to-zero, plug-and-play sensor with automatic temperature compensation and an intelligent algorithm for better environmental adaptability. Its new micro-circuit design provides strong resistance to electromagnetic interference. Calibration is recommended after about six months of use. — Typical uses — Monitoring of hydrogen sulfide and air quality in industrial installations, including livestock and energy production sites mentioned by the manufacturer, with data transmitted to a Modbus RTU-compatible system.

See all specifications

Highlights

  • Supply voltage: 3.3 ~ 5.5V DC (recommended 5V power supply).
  • Ambient Pressure: Atmospheric pressure ±10%.
  • Cable Length: 2 meters
  • H2S — 0~100 ppm( Minimum detection limit:1ppm) — ± 5% F.S: 0.1 ppm
  • Humidity — 10~95 %RH(non-condensation) — ± 2%: 0.1 %RH
  • Measurement — Measurement accuracy: Resolution

Good to know before integrating

  • Power: plan for a supply compatible with 3.3 ~ 5.5V DC (recommended 5V power supply)..
  • Thermal: rated operating range -40°C to 55°C (best operating temperature 20 to 35 °C). — check it against the installation environment.