DFRobot C1001 60 GHz radar sensor for indoor fall detection, human presence sensing and sleep monitoring, operating without camera image capture.
Operating Temperature-20~60°C
Breath Measurement Range10-25 breaths per minute
Heart Rate Measurement Range60-100 beats per minute
Operating Current≤100mA
Operating Frequency61~61.5GHz
Maximum Detection Distance11m
Product overview
Overview. The DFRobot C1001 is a 60 GHz mmWave radar module with built-in algorithms for indoor fall detection, human presence sensing and sleep monitoring. It provides processed sensing results, reducing the need to develop low-level radar analysis for these functions. The sensor operates without capturing camera images.
Main characteristics. Maximum detection distance of 11 m, radar detection angle of 100 × 100 degrees and operating frequency of 61 to 61.5 GHz. The sensor measures breathing rates from 10 to 25 breaths per minute and heart rates from 60 to 100 beats per minute. In sleep mode, the chest detection range is 0.4 to 2.5 m.
Interfaces and connectivity. Processed results are delivered through UART. The module is compatible with ESP32, micro:bit and Arduino UNO development boards and can be configured with the Arduino IDE.
Power and environment. Operating voltage of 5 V, operating current of 100 mA or less, transmission power of 6 dBm and operating temperature range of -20 to 60 °C.
Typical uses. Personal safety monitoring, particularly in elderly care, with alerts for falls, duration of immobility and periods of physical inactivity. Sleep quality monitoring.
Integration. Fall and sleep modes require different mounting arrangements and configurations. A connected controller must read the results and implement logging, local alarms or remote notifications.
DFRobot C1001 60 GHz radar sensor for indoor fall detection, human presence sensing and sleep monitoring, operating without camera image capture.
Operating Temperature-20~60°C
Breath Measurement Range10-25 breaths per minute
Heart Rate Measurement Range60-100 beats per minute
Operating Current≤100mA
Operating Frequency61~61.5GHz
2. Datasheet extract (recorded values)
Parameter
Value
Breath Measurement Range
10-25 breaths per minute
Heart Rate Measurement Range
60-100 beats per minute
Maximum Detection Distance
11m
Operating Current
≤100mA
Operating Frequency
61~61.5GHz
Operating Temperature
-20~60°C
Operating Voltage
5V
Radar Detection Angle
100×100 degrees
Sleep Detection Distance (Chest)
0.4-2.5m
Transmission Power
6dBm
Integration
Points to check before using SEN0623 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20~60°C — check it against the installation environment.
Power and communication
Operating Current
≤100mA
Operating Voltage
5V
Transmission Power
6dBm
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20~60°C — check it against the installation environment.
Applications and use cases
Architectures in which SEN0623 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Meeting rooms are booked but empty, and some areas are always full. Presence sensors, radars and counting cameras measure how spaces are really used, room by room or at entrances
To check
Presence per room or counting at entrances, or both
Privacy requirements, which favour radar or anonymous counting
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productDFRobot
SEN0623
60 GHz Indoor Fall Detection and Sleep Monitoring Radar Sensor
No one to occupied, report within 0.5s Manned to unoccupied, no status output in 1-2 minutes or so
DP10: Fallen state
Two level judgement "suspected fall", "fall alarm" Suspected fall - target fall detected Output status Fall alarm - alarm reported after time T is stationary
DP11: fall alarm reporting time T
Default 3 minutes, divided into 1-30 minute setting steps
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.