WN90SDI – Ultrasonic anemometer weather station with SDI-12 output

Ultrasonic anemometer weather station with SDI-12 output

Weather Stations

  • 1%RH to 99%RH
  • 0Klux to 200Klux
  • 0mm to 6553.5mm
  • 1 to 15
Manufacturer part number
WN90SDI
Manufacturer
Ecowitt
Operating Temperature Range
-40°C to 60°C(-40℉ to 140℉)
Humidity Metering Range
1%RH to 99%RH

Ecowitt WN90SDI multisensor weather station with ultrasonic anemometer, piezoelectric rain gauge and light, UV, temperature, humidity and pressure sensors, with SDI-12 and RS-485 outputs.

Product overview

Overview. The Ecowitt WN90SDI is a multiparameter environmental sensor combining an ultrasonic anemometer, a piezoelectric rain gauge, light and UV sensors and a thermo-hygro-barometer, with an SDI-12 output.

Main characteristics. Wind speed is measured from 0 to 40 m/s with a resolution of 0.1 m/s and an accuracy of ±1 m/s below 10 m/s, and wind direction from 0° to 359° with an accuracy of ±15°. Rainfall is measured from 0 to 6553.5 mm with a resolution of 0.1 mm. Temperature ranges from -40 °C to 60 °C with an accuracy of ±1 °C, humidity from 1 %RH to 99 %RH with an accuracy of ±5 %RH, and barometric pressure from 300 to 1100 hPa with an accuracy of ±5 hPa. Light is measured from 0 to 200 Klux and UV index from 1 to 15.

Interfaces and connectivity. The device provides an SDI-12 output at a baud rate of 1200 bps and an RS-485 interface.

Power and environment. The unit runs on 2 AA batteries (not included) or a DC12V/1A power adapter (not included), with a stated battery life of one month. Its operating range is -40 °C to 60 °C, its protection rating is IPX5, and its casing is made of ASA+PC and PC. Dimensions are 93 × 93 × 208 mm and weight is 498 g.

Typical uses. This type of station suits meteorological and environmental monitoring, measurement of wind, precipitation and sunlight, and integration into an acquisition system compatible with SDI-12 or RS-485.

See all specifications

Highlights

  • Dimensions: 93*93*208mm
  • Barometric Pressure Metering accuracy: ±5hPa
  • Barometric Pressure Metering range: 300 to 1100 hPa (8.85 to 32.5 inHg)
  • Barometric Pressure Metering resolution: 0.1 hPa (0.01 inHg)
  • Battery Life: A month
  • Data Reporting Interval: 8.8 seconds

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -40°C to 60°C(-40℉ to 140℉) — check it against the installation environment.