2D ultrasonic anemometer measuring wind speed and direction with no moving parts, featuring RS485 output and IP66 protection, for meteorological and environmental monitoring.
Basic parameters — Operating temperature-30~60°C
Heating option — Temperature control range-30~60℃
wind direction — Measuring range0-360°
Wind speed — Measuring range0~70 m/s
Basic parameters — Average current<35mA(12VDC)
Heating option — Heating current0.6~1A
Product overview
Fengtu FT-WQX2A2 2D ultrasonic anemometer — the FT-WQX2A2 2D ultrasonic anemometer from manufacturer Fengtu measures wind speed and direction simultaneously using the ultrasonic time difference method. — Main characteristics: wind speed is measured from 0 to 70 m/s with a resolution of 0.1 m/s and a response time of 1 s, and wind direction from 0 to 360° with a resolution of 0.1° and an accuracy of ±2°. The start wind speed is 0.1 m/s. The device has no moving parts and requires no calibration. — Interfaces and connectivity: the output is RS485 or 4-20 mA, with baud rates of 9600, 19200, 38400 and others. — Power and environment: the supply is 9 to 24 VDC with an average current below 35 mA at 12 VDC. The operating temperature range is -30 to 60 °C, the working humidity 0 to 99 %RH, and the protection level IP66. An optional internal heating module, consuming 15 to 25 W and controlled between -30 and 60 °C, allows operation in extreme cold. — Typical uses: urban environmental monitoring, wind power generation, meteorological monitoring, ship navigation, high-speed railway and highway networks, airport environmental monitoring, tunnels and mining. — Integration: the integral stainless steel housing and compact design make installation and transport easy.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for 2D-ULTRASONIC-ANEMOMETER, with where it comes from. Use the filters to find one quickly.
All specifications (21)
Characteristic
Value
Basic parameters — Average current
<35mA(12VDC)
Basic parameters — Baud rate
9600, 19200, 38400, etc.
Basic parameters — Digital signal
RS485 4-20mA
Basic parameters — Operating temperature
-30~60°C
Basic parameters — Protection level
IP66
Basic parameters — voltage
9~24VDC
Basic parameters — Working humidity
0~99%RH
Heating option — Heating current
0.6~1A
Heating option — Power consumption
15~25W
Heating option — Temperature control range
-30~60℃
Photovoltaic Weather Stations
Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants
Water PH Sensor
Selection, Installation, and Maintenance
wind direction — Accuracy
±2°
wind direction — Measuring range
0-360°
wind direction — Resolution
0.1°
wind direction — Start wind speed
0.1m/s
Wind speed — Accuracy
±0.3m/s or ±3% (0-30m/s, whichever is greater) ±5% (30-70m/s)
Wind speed — Measuring range
0~70 m/s
Wind speed — Resolution
0.1m/s
Wind speed — Response time
1s
Wind speed — Start wind speed
0.1m/s
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for 2D-ULTRASONIC-ANEMOMETER. For a missing document or a specific revision, our experts send it to you.
2D ultrasonic anemometer measuring wind speed and direction with no moving parts, featuring RS485 output and IP66 protection, for meteorological and environmental monitoring.
Basic parameters — Operating temperature-30~60°C
Heating option — Temperature control range-30~60℃
wind direction — Measuring range0-360°
Wind speed — Measuring range0~70 m/s
Basic parameters — Average current<35mA(12VDC)
2. Datasheet extract (recorded values)
Parameter
Value
Basic parameters — Average current
<35mA(12VDC)
Basic parameters — Baud rate
9600, 19200, 38400, etc.
Basic parameters — Digital signal
RS485 4-20mA
Basic parameters — Operating temperature
-30~60°C
Basic parameters — Protection level
IP66
Basic parameters — voltage
9~24VDC
Basic parameters — Working humidity
0~99%RH
Heating option — Heating current
0.6~1A
Heating option — Power consumption
15~25W
Heating option — Temperature control range
-30~60℃
Photovoltaic Weather Stations
Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants
Water PH Sensor
Selection, Installation, and Maintenance
wind direction — Accuracy
±2°
wind direction — Measuring range
0-360°
wind direction — Resolution
0.1°
wind direction — Start wind speed
0.1m/s
Wind speed — Accuracy
±0.3m/s or ±3% (0-30m/s, whichever is greater) ±5% (30-70m/s)
Wind speed — Measuring range
0~70 m/s
Wind speed — Resolution
0.1m/s
Wind speed — Response time
1s
Wind speed — Start wind speed
0.1m/s
Integration
Points to check before using 2D-ULTRASONIC-ANEMOMETER in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -30~60°C — check it against the installation environment.
Power and communication
Basic parameters — Average current
<35mA(12VDC)
Basic parameters — voltage
9~24VDC
Heating option — Heating current
0.6~1A
Heating option — Power consumption
15~25W
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -30~60°C — check it against the installation environment.
Applications and use cases
Architectures in which 2D-ULTRASONIC-ANEMOMETER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
Power of the field devices (battery, solar)
Gateway coverage over the farm
Associated system blocks
Weather stationSoil and field sensorsGateway
Need a complete solution?
Send a request for 2D-ULTRASONIC-ANEMOMETER and the other parts of your project.
Answers to the questions that the recorded characteristics of 2D-ULTRASONIC-ANEMOMETER can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Basic parameters — Digital signal": RS485 4-20mA.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details