TP485 – Soil pH sensor with RS485 Modbus RTU output

Soil pH sensor with RS485 Modbus RTU output

pH Sensors

  • 0~14.00(PH)
  • 12-24VDC (0.4W@12V)
  • ±0.1PH, ±0.1℃
  • Standard 5 meters
Manufacturer part number
TP485
Manufacturer
Fengtu
Measuring Range
0~14.00(PH)
Supply voltage
12-24VDC (0.4W@12V)

Soil pH sensor designed to be buried directly in the ground, with RS485 Modbus-RTU digital output for precision agriculture, forestry and geological exploration.

Product overview

Fengtu TP485 soil pH sensor, an electrochemical salt-bridge sensor designed to measure soil pH and indicate whether soil is acidic, neutral or alkaline. The TP485 is a soil pH sensor with RS485 Modbus-RTU output, to be buried directly in the ground.

Measurement. Measuring range of 0 to 14.00 pH, resolution of 0.01, accuracy of ±0.1 pH and ±0.1 ℃. Automatic temperature compensation and response time of about 10 s in flowing liquid (98%) and about 15 s in still liquid (98%).

Connectivity. RS485 signal output with MODBUS-RTU protocol, standard 5-metre cable, M12 aviation connector with 5-pin female socket.

Power and environment. Power supply 12-24 VDC, consumption 0.4 W at 12 V. ABS shell, waterproof level IP68. Measurement environment 0 to 50 ℃ (non-freezing), below 0.2 MPa.

Installation. Submerged installation in soft soil and mud, by drilling with a 20 mm soil auger, then placing the sensor in a soil slurry grout.

Typical uses. Soil pH measurement in precision agriculture, forestry, geological exploration, plant cultivation, water conservancy and environmental protection. The sensor can be buried for long-term dynamic testing, and its environmental data can support photovoltaic weather stations.

See all specifications

Highlights

  • Supply voltage: 12-24VDC (0.4W@12V)
  • Response time: About 10s (98% flowing liquid) about 15s (98% still liquid)
  • Cable Length: Standard 5 meters
  • Installation Method: Submerged installation, soft soil and mud
  • Measurement Accuracy: ±0.1PH, ±0.1℃
  • Measurement environment: Temperature 0~50℃ (non-freezing), <0.2MPa

Good to know before integrating

  • Power: plan for a supply compatible with 12-24VDC (0.4W@12V).

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.