TP485
Soil pH sensor with RS485 Modbus RTU output

- Measuring Range
- 0~14.00(PH)
- Supply voltage
- 12-24VDC (0.4W@12V)
- Measurement Accuracy
- ±0.1PH, ±0.1℃
- Cable Length
- Standard 5 meters
Soil pH sensor with RS485 Modbus RTU output
Soil pH sensor designed to be buried directly in the ground, with RS485 Modbus-RTU digital output for precision agriculture, forestry and geological exploration.
Fengtu TP485 soil pH sensor, an electrochemical salt-bridge sensor designed to measure soil pH and indicate whether soil is acidic, neutral or alkaline. The TP485 is a soil pH sensor with RS485 Modbus-RTU output, to be buried directly in the ground.
Measurement. Measuring range of 0 to 14.00 pH, resolution of 0.01, accuracy of ±0.1 pH and ±0.1 ℃. Automatic temperature compensation and response time of about 10 s in flowing liquid (98%) and about 15 s in still liquid (98%).
Connectivity. RS485 signal output with MODBUS-RTU protocol, standard 5-metre cable, M12 aviation connector with 5-pin female socket.
Power and environment. Power supply 12-24 VDC, consumption 0.4 W at 12 V. ABS shell, waterproof level IP68. Measurement environment 0 to 50 ℃ (non-freezing), below 0.2 MPa.
Installation. Submerged installation in soft soil and mud, by drilling with a 20 mm soil auger, then placing the sensor in a soil slurry grout.
Typical uses. Soil pH measurement in precision agriculture, forestry, geological exploration, plant cultivation, water conservancy and environmental protection. The sensor can be buried for long-term dynamic testing, and its environmental data can support photovoltaic weather stations.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for TP485, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Supply voltage | 12-24VDC (0.4W@12V) |
| Response time | About 10s (98% flowing liquid) about 15s (98% still liquid) |
| Cable Length | Standard 5 meters |
| Installation Method | Submerged installation, soft soil and mud |
| Measurement Accuracy | ±0.1PH, ±0.1℃ |
| Measurement environment | Temperature 0~50℃ (non-freezing), <0.2MPa |
| Measurement Principle | Electrochemistry (Salt Bridge) |
| Measurement Resolution | 0.01 |
| Measuring Range | 0~14.00(PH) |
| Photovoltaic Weather Stations | Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants |
| Shell material | ABS |
| Signal mode | RS485 (MODBUS-RTU) |
| Temperature Compensation | Automatic temperature compensation |
| Water PH Sensor | Selection, Installation, and Maintenance |
| Waterproof level | IP68 |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for TP485. For a missing document or a specific revision, our experts send it to you.
Soil pH sensor designed to be buried directly in the ground, with RS485 Modbus-RTU digital output for precision agriculture, forestry and geological exploration.
| Parameter | Value |
|---|---|
| Supply voltage | 12-24VDC (0.4W@12V) |
| Response time | About 10s (98% flowing liquid) about 15s (98% still liquid) |
| Cable Length | Standard 5 meters |
| Installation Method | Submerged installation, soft soil and mud |
| Measurement Accuracy | ±0.1PH, ±0.1℃ |
| Measurement environment | Temperature 0~50℃ (non-freezing), <0.2MPa |
| Measurement Principle | Electrochemistry (Salt Bridge) |
| Measurement Resolution | 0.01 |
| Measuring Range | 0~14.00(PH) |
| Photovoltaic Weather Stations | Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants |
| Shell material | ABS |
| Signal mode | RS485 (MODBUS-RTU) |
| Temperature Compensation | Automatic temperature compensation |
| Water PH Sensor | Selection, Installation, and Maintenance |
| Waterproof level | IP68 |
Points to check before using TP485 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Supply voltage | 12-24VDC (0.4W@12V) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of TP485 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Signal mode": RS485 (MODBUS-RTU).
Yes — recorded under "Signal mode": RS485 (MODBUS-RTU).
12-24VDC (0.4W@12V) (source: Supply voltage).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Soil pH sensor with RS485 Modbus RTU output

Water PH Sensor

PH installation accessories

MDA-PH pH ORP meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | TP485 |
| Manufacturer | Fengtu |
pH Sensors
Industrial soil monitoring station with RS485 interface · Ref. : MAIGSRM
Price on request
pH Sensors
Industrial Online ORP Sensor with Platinum Bulb · Ref. : ORP8083-INDUSTRIAL-ORP-SENSOR
Price on request
pH Sensors
Chemical-Resistant UHF RFID Hard Tag for Metal Surfaces
Price on request
pH Sensors
Analog Composite Glass pH Electrode · Ref. : ASP200
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details