FT-S3 – Water pH sensor with RS485 Modbus RTU output

Water pH sensor with RS485 Modbus RTU output

pH Sensors

  • 0~14.00(PH)
  • 12-24VDC (0.4W@12V)
  • ±0.1PH, ±0.1℃
  • Standard 5 meters
Manufacturer part number
WATER-PH-SENSOR
Manufacturer
Fengtu
Measuring Range
0~14.00(PH)
Supply voltage
12-24VDC (0.4W@12V)

Immersion water pH sensor for pH monitoring and control in industrial processes and wastewater treatment, with RS485 MODBUS-RTU output.

Product overview

Fengtu FT-S3. The Fengtu FT-S3 water pH sensor is an immersion pH sensor designed for pH monitoring and control in various production processes and in wastewater treatment.

Main characteristics. Measuring range of 0 to 14.00 pH, resolution of 0.01, accuracy of ±0.1 pH and ±0.1 ℃. Electrochemical measuring principle with salt bridge, with automatic temperature compensation. Response time of about 10 s in flowing liquid and about 15 s in stationary liquid.

Interfaces and connectivity. RS485 signal (MODBUS-RTU). Standard 5-metre cable, 5-core shielded, with brown (power 12 to 24 VDC), black (ground GND), green (485B) and yellow (485A) wires.

Power and environment. Supply voltage of 12 to 24 VDC, consumption of 0.4 W at 12 V. Measurement environment temperature of 0 to 50 ℃ (no freezing), pressure below 0.2 MPa. ABS housing, waterproof grade IP68.

Installation. Immersion installation with NPT 3/4 thread, suitable for tanks and pipes. The sensor must not be installed upside down or horizontally, but at an angle of at least 15 degrees. About one third of the sensor should be inserted into the measured liquid.

Maintenance. When used for the first time or after long-term disuse, the sensitive bulb and reference junction should be immersed in 3.3 mol/L KCl solution for more than 2 hours. The sensor should be rinsed with deionized or distilled water, and avoid prolonged immersion in strong acid or alkali solutions, as well as any contact with silicone grease.

See all specifications

Highlights

  • Supply voltage: 12-24VDC (0.4W@12V)
  • Response time: About 10s (98% flowing liquid) About 15s (98% stationary liquid)
  • Cable Length: Standard 5 meters
  • Installation: Immersion installation, NPT3/4 thread
  • Measurement Accuracy: ±0.1PH, ±0.1℃
  • Measurement environment: Temperature 0~50℃ (no freezing), < 0.2MPa

Good to know before integrating

  • Power: plan for a supply compatible with 12-24VDC (0.4W@12V).