WATER-PH-SENSOR
Water pH sensor with RS485 Modbus RTU output

- Measuring Range
- 0~14.00(PH)
- Supply voltage
- 12-24VDC (0.4W@12V)
- Measurement Accuracy
- ±0.1PH, ±0.1℃
- Cable Length
- Standard 5 meters
Water pH sensor with RS485 Modbus RTU output
Immersion water pH sensor for pH monitoring and control in industrial processes and wastewater treatment, with RS485 MODBUS-RTU output.
Fengtu FT-S3. The Fengtu FT-S3 water pH sensor is an immersion pH sensor designed for pH monitoring and control in various production processes and in wastewater treatment.
Main characteristics. Measuring range of 0 to 14.00 pH, resolution of 0.01, accuracy of ±0.1 pH and ±0.1 ℃. Electrochemical measuring principle with salt bridge, with automatic temperature compensation. Response time of about 10 s in flowing liquid and about 15 s in stationary liquid.
Interfaces and connectivity. RS485 signal (MODBUS-RTU). Standard 5-metre cable, 5-core shielded, with brown (power 12 to 24 VDC), black (ground GND), green (485B) and yellow (485A) wires.
Power and environment. Supply voltage of 12 to 24 VDC, consumption of 0.4 W at 12 V. Measurement environment temperature of 0 to 50 ℃ (no freezing), pressure below 0.2 MPa. ABS housing, waterproof grade IP68.
Installation. Immersion installation with NPT 3/4 thread, suitable for tanks and pipes. The sensor must not be installed upside down or horizontally, but at an angle of at least 15 degrees. About one third of the sensor should be inserted into the measured liquid.
Maintenance. When used for the first time or after long-term disuse, the sensitive bulb and reference junction should be immersed in 3.3 mol/L KCl solution for more than 2 hours. The sensor should be rinsed with deionized or distilled water, and avoid prolonged immersion in strong acid or alkali solutions, as well as any contact with silicone grease.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for WATER-PH-SENSOR, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Supply voltage | 12-24VDC (0.4W@12V) |
| Response time | About 10s (98% flowing liquid) About 15s (98% stationary liquid) |
| Cable Length | Standard 5 meters |
| Installation | Immersion installation, NPT3/4 thread |
| Measurement Accuracy | ±0.1PH, ±0.1℃ |
| Measurement environment | Temperature 0~50℃ (no freezing), < 0.2MPa |
| Measurement Resolution | 0.01 |
| Measuring Principle | Electrochemistry (Salt Bridge) |
| Measuring Range | 0~14.00(PH) |
| Photovoltaic Weather Stations | Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants |
| Shell material | ABS |
| Signal method | RS485 (MODBUS-RTU) |
| Temperature Compensation | Automatic temperature compensation |
| Water PH Sensor | Selection, Installation, and Maintenance |
| Waterproof Grade | IP68 |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for WATER-PH-SENSOR. For a missing document or a specific revision, our experts send it to you.
Immersion water pH sensor for pH monitoring and control in industrial processes and wastewater treatment, with RS485 MODBUS-RTU output.
| Parameter | Value |
|---|---|
| Supply voltage | 12-24VDC (0.4W@12V) |
| Response time | About 10s (98% flowing liquid) About 15s (98% stationary liquid) |
| Cable Length | Standard 5 meters |
| Installation | Immersion installation, NPT3/4 thread |
| Measurement Accuracy | ±0.1PH, ±0.1℃ |
| Measurement environment | Temperature 0~50℃ (no freezing), < 0.2MPa |
| Measurement Resolution | 0.01 |
| Measuring Principle | Electrochemistry (Salt Bridge) |
| Measuring Range | 0~14.00(PH) |
| Photovoltaic Weather Stations | Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants |
| Shell material | ABS |
| Signal method | RS485 (MODBUS-RTU) |
| Temperature Compensation | Automatic temperature compensation |
| Water PH Sensor | Selection, Installation, and Maintenance |
| Waterproof Grade | IP68 |
Points to check before using WATER-PH-SENSOR in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Supply voltage | 12-24VDC (0.4W@12V) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of WATER-PH-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Signal method": RS485 (MODBUS-RTU).
Yes — recorded under "Signal method": RS485 (MODBUS-RTU).
12-24VDC (0.4W@12V) (source: Supply voltage).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Water pH sensor with RS485 Modbus RTU output

Soil PH Sensor

PH installation accessories

MDA-PH pH ORP meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | WATER-PH-SENSOR |
| Manufacturer | Fengtu |
pH Sensors
Industrial soil monitoring station with RS485 interface
Price on request
pH Sensors
Industrial Online ORP Sensor with Platinum Bulb
Price on request
pH Sensors
Chemical-Resistant UHF RFID Hard Tag for Metal Surfaces
Price on request
pH Sensors
Analog Composite Glass pH Electrode · Ref. : ASP200
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details