FT-S16S – Blue-green algae sensor, fluorescence method, RS485 output

Blue-green algae sensor, fluorescence method, RS485 output

Environmental and Gas Sensors

  • 0~200.0Kcells/mL
  • 12-24VDC (0.4W@12V)
  • Standard 5 meters
  • Two point calibration
Manufacturer part number
WATER-BLUE-GREEN-ALGAE-SENSOR
Manufacturer
Fengtu
Measuring Range
0~200.0Kcells/mL
Supply voltage
12-24VDC (0.4W@12V)

Submersible blue-green algae sensor measuring cyanobacteria by fluorescence, with RS485 MODBUS RTU output, for continuous water quality monitoring.

Product overview

Fengtu FT-S16S. blue-green algae (cyanobacteria) sensor using fluorescence. The FT-S16S is a submersible sensor that measures blue-green algae concentration by exploiting the fluorescence of phycocyanin, a pigment present in these organisms. A beam of a specific wavelength excites the phycocyanin and the intensity of the emitted fluorescence is detected.

Measurement characteristics. Measuring range 0 to 200.0 Kcells/mL, measurement resolution 0.1 Kcells/mL, detection limit 1.0 Kcells/mL. Two-point calibration, linearity R² > 0.999.

Interfaces and connectivity. RS485 digital output with MODBUS-RTU protocol, standard 5-meter cable with 4 shielded conductors. M12 aviation 5-pin female connector. Internal signal isolation for strong interference resistance.

Power and environment. Supply voltage 12 to 24 VDC, 0.4 W at 12 V. Measurement temperature 0 to 50 °C (non-freezing), pressure below 0.2 MPa. Waterproof rating IP68. Housing in glass, 316L stainless steel and ABS plastic.

Cleaning and maintenance. Integrated automatic cleaner preventing biological adhesion and light window pollution, with adjustable cleaning time and frequency, power consumption 0.7 W. Submersible installation or installation in pipes and tanks via 3/4 NPT thread.

Typical uses. Water quality monitoring and integration into a supervision system via RS485 MODBUS.

See all specifications

Highlights

  • Supply voltage: 12-24VDC (0.4W@12V)
  • Cable Length: Standard 5 meters
  • Calibration method: Two point calibration
  • detection limit: 1.0Kcells/mL
  • Installation Method: Submersible installation, NPT3/4 thread
  • Linearity: R²>0.999

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Power: plan for a supply compatible with 12-24VDC (0.4W@12V).