GH3026
Ultra-low-power PPG heart rate sensor module

- PPG dynamic range
- up to 110 dB
- Communication Interface SPI
- up to 12 MHz
- Interface
- IIC/SPI
- Package
- WLCSP-42
Ultra-low-power PPG heart rate sensor module
The Goodix GH3026 is an ultra-low-power PPG heart rate sensor that measures heart rate, heart rate variability and blood oxygen saturation for smartwatches and wristbands.
Goodix GH3026. PPG heart rate sensor in WLCSP-42 package. The Goodix GH3026 is an ultra-low-power, high-precision heart rate sensor that integrates multichannel PPG sensing circuits. It monitors heart rate (HR), heart rate variability (HRV) and peripheral capillary oxygen saturation (SpO2).
Key characteristics. 24-bit analog-to-digital converter, PPG dynamic range up to 110 dB, 8 single-ended and 4 differential PPG receive inputs, two PPG transmit drivers of 200 mA each, 3.2k-byte FIFO. Average current consumption of 59 µA in heart rate mode and 230 µA in SpO2 mode. DC background light rejection (BGR) of 80 dB and AC background light rejection at 50 Hz of 60 dB.
Interfaces and connectivity. IIC interface up to 1 MHz and SPI interface up to 12 MHz. The device supports HR, SpO2 and HRV algorithms as well as wear detection.
Dimensions and package. 2.605 mm × 2.905 mm × 0.468 mm, 0.4 mm pitch, 42 balls, WLCSP-42 package.
Typical uses. High-end smartwatches, smart wristbands, professional sports gear and medical devices. The GH3026 is available on quotation from Atlas Electronics.
Integration. Development documentation includes the register datasheet, the reference schematic and bill of materials, the GH(M)3x2x evaluation kit hardware user guide and the GHealth user manual.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for GH3026, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Analog-to-digital converter | 24-bit |
| Package | WLCSP-42 |
| Algorithm | HR, SpO2, HRV, Wear Detect |
| Chip Size (mm) | 2.6 * 2.9 * 0.46 |
| Communication Interface SPI | up to 12 MHz |
| DC background light rejection (BGR) | 80 dB |
| FIFO | 3.2k bytes |
| GH3026(2.905X2.605X0.468)_POD — Nda Users Only — Rev.1.0 | 2022-07-16 |
| GH3026_Datasheet — Register Users Only — Rev.1.2 | 2021-07-23 |
| GH3026_Schematic_BOM — Nda Users Only — Rev.1.2 | 2022-07-16 |
| GH3026_Schematic — Register Users Only — Rev.1.1 | 2021-03-19 |
| GH(M)3x2x EVK Hardware User Guide — Nda Users Only — Rev.1.0 | 2020-08-04 |
| GHealth_User_Manual — Nda Users Only — Rev.1.2 | 2021-08-17 |
| IIC | up to 1 MHz |
| Interface | IIC/SPI |
| PPG dynamic range | up to 110 dB |
| PPG RX | 8 Single/ 4 Diff |
| PPG TX | 200 mA * 2 |
| Size | 2.605 mm * 2.905 mm * 0.468 mm, 0.4 mm pitch, 42 balls |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for GH3026. For a missing document or a specific revision, our experts send it to you.
The Goodix GH3026 is an ultra-low-power PPG heart rate sensor that measures heart rate, heart rate variability and blood oxygen saturation for smartwatches and wristbands.
| Parameter | Value |
|---|---|
| Analog-to-digital converter | 24-bit |
| Package | WLCSP-42 |
| Algorithm | HR, SpO2, HRV, Wear Detect |
| Chip Size (mm) | 2.6 * 2.9 * 0.46 |
| Communication Interface SPI | up to 12 MHz |
| DC background light rejection (BGR) | 80 dB |
| FIFO | 3.2k bytes |
| GH3026(2.905X2.605X0.468)_POD — Nda Users Only — Rev.1.0 | 2022-07-16 |
| GH3026_Datasheet — Register Users Only — Rev.1.2 | 2021-07-23 |
| GH3026_Schematic_BOM — Nda Users Only — Rev.1.2 | 2022-07-16 |
| GH3026_Schematic — Register Users Only — Rev.1.1 | 2021-03-19 |
| GH(M)3x2x EVK Hardware User Guide — Nda Users Only — Rev.1.0 | 2020-08-04 |
| GHealth_User_Manual — Nda Users Only — Rev.1.2 | 2021-08-17 |
| IIC | up to 1 MHz |
| Interface | IIC/SPI |
| PPG dynamic range | up to 110 dB |
| PPG RX | 8 Single/ 4 Diff |
| PPG TX | 200 mA * 2 |
| Size | 2.605 mm * 2.905 mm * 0.468 mm, 0.4 mm pitch, 42 balls |
Answers to the questions that the recorded characteristics of GH3026 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication Interface SPI": up to 12 MHz.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Ultra-low-power PPG heart rate sensor module


Heart Rate Sensor Maxim Integrated MAX30102


Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | GH3026 |
| Manufacturer | Goodix |
Heart Rate Sensor Modules
Heart Rate and Pulse Oximeter Sensor with Reflective LED · Ref. : 100046
Price on request
Heart Rate Sensor Modules
Multichannel PPG and single-lead ECG heart rate sensor module · Ref. : GH3220
Price on request
Heart Rate Sensor Modules
Ultra-low-power multichannel PPG heart rate sensor · Ref. : GH3020
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details