100046
Heart Rate and Pulse Oximeter Sensor with Reflective LED

- Operating Temperature Range
- Minimum: -40; Maximum: 85; Unit: °C
- 1V8
- Minimum: -0.3; Maximum: 2.2; Unit: V
- 3V3_S
- Minimum: -0.3; Maximum: 6; Unit: V
- Analog Devices
- MAX30102
Heart Rate and Pulse Oximeter Sensor with Reflective LED
RAK12012 module from the WisBlock Sensor range, integrating a pulse oximeter and heart rate monitor based on the Analog Devices MAX30102 to measure heart rate and blood oxygen saturation.
Overview. The RAKwireless RAK12012 is a heart rate and pulse oximeter sensor module from the WisBlock Sensor range. It uses the Analog Devices MAX30102 chip to measure a person's heart rate and oxygen saturation, attached to the fingertip.
Main characteristics. The sensor uses a reflective LED solution, offers robust motion artifact resilience and fast data output capability. It operates from a 3.3 V supply over a temperature range of -40 °C to +85 °C.
Power consumption. Operating current ranges from 0.7 to 1200 uA depending on the mode, with ultra-low power operation. Shutdown current is 0.7 uA nominal at +25 °C.
Format and connectivity. The module measures 25 mm x 35 mm and connects through a 40-pin connector, with an INT interrupt pin and an I2C bus (SDA and SCL).
Typical uses. Suited to physiological monitoring and prototyping of personal health or medical sensing applications within a WisBlock system, thanks to its I2C interface.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 100046, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| 1V8 | Minimum: -0.3; Maximum: 2.2; Unit: V |
| 3V3_S | Minimum: -0.3; Maximum: 6; Unit: V |
| Analog Devices | MAX30102 |
| Continuous Power Dissipation | Maximum: 440; Unit: mW |
| ESD_HBM | Maximum: 2.5; Unit: KV |
| IDD1 | Description: Supply Current; Condition: SpO2 and HR mode,PW = 215 µs,50 sps; Nom.: 600; Max.: 1200; Unit: uA |
| IDD2 | Description: Supply Curren; Condition: IR only mode, PW = 215 µS, 50 sps; Nom.: 600; Max.: 1200; Unit: uA |
| ISHDN | Description: Supply Current in Shutdown; Condition: TA = +25 °C, MODE = 0x80; Nom.: 0.7; Max.: 10; Unit: uA |
| Model | RAK12012 |
| Module size | 25 X 35mm |
| Operating Temperature Range | Minimum: -40; Maximum: 85; Unit: °C |
No specification matches.
Last verification : 2026-10-31
Official documents and the technical data recorded for 100046. For a missing document or a specific revision, our experts send it to you.
RAK12012 module from the WisBlock Sensor range, integrating a pulse oximeter and heart rate monitor based on the Analog Devices MAX30102 to measure heart rate and blood oxygen saturation.
| Parameter | Value |
|---|---|
| 1V8 | Minimum: -0.3; Maximum: 2.2; Unit: V |
| 3V3_S | Minimum: -0.3; Maximum: 6; Unit: V |
| Analog Devices | MAX30102 |
| Continuous Power Dissipation | Minimum: -; Maximum: 440; Unit: mW |
| ESD_HBM | Minimum: -; Maximum: 2.5; Unit: KV |
| IDD1 | Description: Supply Current; Condition: SpO2 and HR mode,PW = 215 µs,50 sps; Min.: -; Nom.: 600; Max.: 1200; Unit: uA |
| IDD2 | Description: Supply Curren; Condition: IR only mode, PW = 215 µS, 50 sps; Min.: -; Nom.: 600; Max.: 1200; Unit: uA |
| ISHDN | Description: Supply Current in Shutdown; Condition: TA = +25 °C, MODE = 0x80; Min.: -; Nom.: 0.7; Max.: 10; Unit: uA |
| Model | RAK12012 |
| Module size | 25 X 35mm |
| Operating Temperature Range | Minimum: -40; Maximum: 85; Unit: °C |
Points to check before using 100046 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Continuous Power Dissipation | Maximum: 440; Unit: mW |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of 100046 can answer. A question is not asked when nothing is recorded to answer it.
Minimum: -40; Maximum: 85; Unit: °C (source: Operating Temperature Range).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Heart Rate and Pulse Oximeter Sensor with Reflective LED




Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 100046 |
| Family | Heart Rate Sensor Maxim Integrated MAX30102 |
| Manufacturer | RAKwireless |
Heart Rate Sensor Modules
Multichannel PPG and single-lead ECG heart rate sensor module · Ref. : GH3220
Price on request
Heart Rate Sensor Modules
Ultra-low-power multichannel PPG heart rate sensor · Ref. : GH3020
Price on request
Heart Rate Sensor Modules
Ultra-low-power PPG heart rate sensor module · Ref. : GH3026
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details