S1850V2-EI
Layer 2 Gigabit access switch with PoE+ ports

- VLAN interface
- Both IPv4 and IPv6 supported
- Total Power Consumption
- MIN:; AC: 8W; MAX:; AC: 15W
- Flash/SDRAM
- 256MB/512MB
- Storage Temperature
- -40℃ ~ 70℃
Layer 2 Gigabit access switch with PoE+ ports
The H3C S1850V2-EI Layer 2 Gigabit access switch suits enterprise, education and security networks. It provides 10/100/1000BASE-T ports and SFP uplinks, with PoE+ models available.
Overview. The H3C S1850V2-EI Ethernet switch is a Layer 2 Gigabit access switch with GE uplink ports, designed for high-performance networks in government offices, small and medium-sized enterprises, education, security monitoring and hotels.
Main characteristics. The switch offers a switching capacity of 20 Gbps and a forwarding capacity of 15 Mpps, with a wire-speed architecture. Its MAC address table holds 16K entries, including 1K static MAC addresses. The processor is a single-core 800 MHz CPU, with 256 MB flash and 512 MB SDRAM.
Interfaces and connectivity. The S1850V2-10P-EI provides 8 10/100/1000BASE-T ports and 2 1000BASE-X SFP ports, the S1850V2-28P-EI 24 10/100/1000BASE-T ports and 4 SFP ports, and the S1850V2-52P-EI 48 10/100/1000BASE-T ports and 4 SFP ports. The HPWR variants provide PoE+ ports: 125 W for the 10-port model and 370 W for the 28-port model. The switch includes a console port, port-based and MAC-based VLAN, static and dynamic link aggregation, and IGMP Snooping V2/V3.
Security and management. The switch supports 802.1X, AAA authentication, RADIUS, HWTACACS, SSH 2.0, HTTPS, port isolation, port security, IP Source Guard and ARP detection. It can be managed through CLI, Telnet, console, Web, SNMPv1/v2c/v3, RMON and NTP. STP, RSTP and MSTP provide loop protection.
Power and environment. The input voltage range is 100 V to 240 V, 50/60 Hz. Power consumption is 8 W minimum and 15 W maximum. The S1850V2-10P-EI, S1850V2-10P-HPWR-EI and S1850V2-28P-EI are fan-less. The operating temperature ranges from -5 °C to 50 °C.
Typical uses. This switch suits enterprise, campus and security access networks, in particular to power PoE+ devices such as IP cameras or access points while providing port security and VLAN segmentation.
Integration. The switch is compatible with the SFP-GE-SX-MM850-A, SFP-GE-LX-SM1310-A and SFP-GE-T transceivers. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S1850V2-EI, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| ACL | Packet filtering at Layer 2 through layer 4 Traffic classification based on source MAC addresses, destination MAC addresses, source IPv4/IPv6 addresses,; Time range-based ACL; VLAN-based ACL; Bidirectional ACL |
| ARP | ARP Detection; ARP speed limit |
| Broadcast/Multicast/Unicast storm suppression | Storm suppression based on port bandwidth percentage; Storm suppression based on PPS; Storm suppression based on BPS; Broadcast traffic/Multicast traffic/Unknown unicast traffic suppression |
| CPU | 1 Core, 800MHz |
| DHCP | DHCP Client; DHCP Snooping; DHCP Snooping option82; DHCP Relay; DHCP auto-config |
| Dimensions (W/D/H) | 266×161×43.6mm |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 35; EN 55035; EN 61000-3-2; EN 61000-3-3; GB/T 9254.1 |
| Ethernet features | 802.3x traffic control and half-duplex backpressure; Green Ethernet (EEE); Automatic port energy-saving |
| Fan number | Fan-less |
| Flash/SDRAM | 256MB/512MB |
| Forwarding | Wire-speed/Line-rate architecture |
| Forwarding Capacity | 15Mpps |
| IEEE | 802.1x Port based network access control protocol |
| IETF | RFC 768 User Datagram Protocol (UDP) |
| Input Voltage | AC: The rated voltage range is 100V to 240V, 50/60Hz. |
| IP Routing | Static routing |
| ITU | ITU-T Y.1731 |
| Layer 2 Ring Network Protocol | STP/RSTP/MSTP/PVST/PVST+; BPDU protection/root protection/loopback protection/protection against TC-BPDU attack |
| LS-1850V2-10P-EI-GL | H3C S1850V2-10P-EI L2 Ethernet Switch with 8*10/100/1000BASE-T Ports and 2*1000BASE-X SFP Ports,(AC) |
| LS-1850V2-10P-HPWR-EI-GL | H3C S1850V2-10P-HPWR-EI L2 Ethernet Switch with 8*10/100/1000BASE-T PoE+ Ports (AC 125W) and 2*1000BASE-X SFP Ports,(AC) |
| LS-1850V2-28P-EI-GL | H3C S1850V2-28P-EI L2 Ethernet Switch with 24*10/100/1000BASE-T Ports and 4*1000BASE-X SFP Ports,(AC) |
| LS-1850V2-28P-HPWR-EI-GL | H3C S1850V2-28P-HPWR-EI L2 Ethernet Switch with 24*10/100/1000BASE-T PoE+ Ports (AC 370W) and 4*1000BASE-X SFP Ports,(AC) |
| LS-1850V2-52P-EI-GL | H3C S1850V2-52P-EI L2 Ethernet Switch with 48*10/100/1000BASE-T Ports and 4*1000BASE-X SFP Ports,(AC) |
| MAC address entries | 16K |
| MAC Address Table | Static MAC address; Blackhole MAC address; Setting the maximum number of port MAC addresses to be learned |
| Management and maintenance | Loading and upgrading through XModem/FTP/TFTP; Zero Touch Provisioning; Configuration through CLI, Telnet, and console port; SNMPv1/v2c/v3 and Web-based NMS; Restful; Remote monitoring (RMON ) alarm, event, and history recording; IMC NMS; System log, alarming based on severities, and output of debugging information; NTP; Ping, Tracert; NQA; Virtual cable test (VCT); Device link detection protocol (DLDP); Loopback-detection |
| Management port | 1 console port |
| Mirroring | Port mirroring; Traffic mirroring; RSPAN |
| MTBF(year) | 140.82 |
| Multicast | IGMP Snooping V2/V3; PIM Snooping; MLD Snooping; Multicast VLAN |
| Networking Interface | 8 10/100/1000Base-T electrical ports; 2 1000Base-X SFP optical port |
| Operating Temperature | -5℃ ~ 50℃(normal operating temperature); -5℃ ~ 45℃(When using transceiver modules with maximum transmission distance < 80km); -5℃ ~ 40℃(When using transceiver modules with maximum transmission distance ≥ 80km) |
| Organization | Standards And Protocols |
| Port Aggregation | GE port aggregation; Dynamic aggregation; Static aggregation |
| Port Surge | 6KV |
| Product ID | Product Description |
| QoS | Port rate limit (receiving and transmitting); Packet redirection; Committed access rate (CAR); Eight output queues on each port; Flexible queue scheduling algorithms based on ports and queues, including SP, WRR and SP+WRR; 802.1p DSCP remarking |
| Relative humidity (non-condensing) | 5% RH to 95% RH, non-condensing |
| S1850V2-10P-HPWR-EI — 125W | 15.4W (802.3af): 8; 30W (802.3at): 4 |
| S1850V2-28P-HPWR-EI — 370W | 15.4W (802.3af): 24; 30W (802.3at): 12 |
| Safety | UL 62368-1; CAN/CSA C22.2 No 62368-1; IEC 62368-1; EN 62368-1; AS/NZS 62368-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| Security | Hierarchical user management and password protection; AAA authentication support; RADIUS authentication; HWTACACS; SSH2.0; Port isolation; 802.1X authentication, centralized MAC authentication; Port security; IP/Port/MAC binding; IP Source Guard; HTTPs |
| SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| SFP-GE-T | SFP GE Copper Interface Transceiver Module (100m,RJ45) |
| Static Mac address | 1K |
| Storage Temperature | -40℃ ~ 70℃ |
| Switching Capacity | 20 Gbps |
| Total Power Consumption | MIN:; AC: 8W; MAX:; AC: 15W |
| Traffic statistic | Sflow |
| VLAN | Port-based VLAN; MAC-based VLAN; VLAN mapping; MVRP; Voice VLAN* |
| VLAN interface | Both IPv4 and IPv6 supported |
| Weight | ≤ 1.5 kg |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S1850V2-EI. For a missing document or a specific revision, our experts send it to you.
The H3C S1850V2-EI Layer 2 Gigabit access switch suits enterprise, education and security networks. It provides 10/100/1000BASE-T ports and SFP uplinks, with PoE+ models available.
| Parameter | Value |
|---|---|
| ACL | Packet filtering at Layer 2 through layer 4 Traffic classification based on source MAC addresses, destination MAC addresses, source IPv4/IPv6 addresses,; Time range-based ACL; VLAN-based ACL; Bidirectional ACL |
| ARP | ARP Detection; ARP speed limit |
| Broadcast/Multicast/Unicast storm suppression | Storm suppression based on port bandwidth percentage; Storm suppression based on PPS; Storm suppression based on BPS; Broadcast traffic/Multicast traffic/Unknown unicast traffic suppression |
| CPU | 1 Core, 800MHz |
| DHCP | DHCP Client; DHCP Snooping; DHCP Snooping option82; DHCP Relay; DHCP auto-config |
| Dimensions (W/D/H) | 266×161×43.6mm |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 35; EN 55035; EN 61000-3-2; EN 61000-3-3; GB/T 9254.1 |
| Ethernet features | 802.3x traffic control and half-duplex backpressure; Green Ethernet (EEE); Automatic port energy-saving |
| Fan number | Fan-less |
| Flash/SDRAM | 256MB/512MB |
| Forwarding | Wire-speed/Line-rate architecture |
| Forwarding Capacity | 15Mpps |
| IEEE | 802.1x Port based network access control protocol |
| IETF | RFC 768 User Datagram Protocol (UDP) |
| Input Voltage | AC: The rated voltage range is 100V to 240V, 50/60Hz. |
| IP Routing | Static routing |
| ITU | ITU-T Y.1731 |
| Layer 2 Ring Network Protocol | STP/RSTP/MSTP/PVST/PVST+; BPDU protection/root protection/loopback protection/protection against TC-BPDU attack |
| LS-1850V2-10P-EI-GL | H3C S1850V2-10P-EI L2 Ethernet Switch with 8*10/100/1000BASE-T Ports and 2*1000BASE-X SFP Ports,(AC) |
| LS-1850V2-10P-HPWR-EI-GL | H3C S1850V2-10P-HPWR-EI L2 Ethernet Switch with 8*10/100/1000BASE-T PoE+ Ports (AC 125W) and 2*1000BASE-X SFP Ports,(AC) |
| LS-1850V2-28P-EI-GL | H3C S1850V2-28P-EI L2 Ethernet Switch with 24*10/100/1000BASE-T Ports and 4*1000BASE-X SFP Ports,(AC) |
| LS-1850V2-28P-HPWR-EI-GL | H3C S1850V2-28P-HPWR-EI L2 Ethernet Switch with 24*10/100/1000BASE-T PoE+ Ports (AC 370W) and 4*1000BASE-X SFP Ports,(AC) |
| LS-1850V2-52P-EI-GL | H3C S1850V2-52P-EI L2 Ethernet Switch with 48*10/100/1000BASE-T Ports and 4*1000BASE-X SFP Ports,(AC) |
| MAC address entries | 16K |
| MAC Address Table | Static MAC address; Blackhole MAC address; Setting the maximum number of port MAC addresses to be learned |
| Management and maintenance | Loading and upgrading through XModem/FTP/TFTP; Zero Touch Provisioning; Configuration through CLI, Telnet, and console port; SNMPv1/v2c/v3 and Web-based NMS; Restful; Remote monitoring (RMON ) alarm, event, and history recording; IMC NMS; System log, alarming based on severities, and output of debugging information; NTP; Ping, Tracert; NQA; Virtual cable test (VCT); Device link detection protocol (DLDP); Loopback-detection |
| Management port | 1 console port |
| Mirroring | Port mirroring; Traffic mirroring; RSPAN |
| MTBF(year) | 140.82 |
| Multicast | IGMP Snooping V2/V3; PIM Snooping; MLD Snooping; Multicast VLAN |
| Networking Interface | 8 10/100/1000Base-T electrical ports; 2 1000Base-X SFP optical port |
| Operating Temperature | -5℃ ~ 50℃(normal operating temperature); -5℃ ~ 45℃(When using transceiver modules with maximum transmission distance < 80km); -5℃ ~ 40℃(When using transceiver modules with maximum transmission distance ≥ 80km) |
| Organization | Standards And Protocols |
| Port Aggregation | GE port aggregation; Dynamic aggregation; Static aggregation |
| Port Surge | 6KV |
| Product ID | Product Description |
| QoS | Port rate limit (receiving and transmitting); Packet redirection; Committed access rate (CAR); Eight output queues on each port; Flexible queue scheduling algorithms based on ports and queues, including SP, WRR and SP+WRR; 802.1p DSCP remarking |
| Relative humidity (non-condensing) | 5% RH to 95% RH, non-condensing |
| S1850V2-10P-HPWR-EI — 125W | 15.4W (802.3af): 8; 30W (802.3at): 4 |
| S1850V2-28P-HPWR-EI — 370W | 15.4W (802.3af): 24; 30W (802.3at): 12 |
| Safety | UL 62368-1; CAN/CSA C22.2 No 62368-1; IEC 62368-1; EN 62368-1; AS/NZS 62368-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| Security | Hierarchical user management and password protection; AAA authentication support; RADIUS authentication; HWTACACS; SSH2.0; Port isolation; 802.1X authentication, centralized MAC authentication; Port security; IP/Port/MAC binding; IP Source Guard; HTTPs |
| SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| SFP-GE-T | SFP GE Copper Interface Transceiver Module (100m,RJ45) |
| Static Mac address | 1K |
| Storage Temperature | -40℃ ~ 70℃ |
| Switching Capacity | 20 Gbps |
| Total Power Consumption | MIN:; AC: 8W; MAX:; AC: 15W |
| Traffic statistic | Sflow |
| VLAN | Port-based VLAN; MAC-based VLAN; VLAN mapping; MVRP; Voice VLAN* |
| VLAN interface | Both IPv4 and IPv6 supported |
| Weight | ≤ 1.5 kg |
Answers to the questions that the recorded characteristics of S1850V2-EI can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Safety": UL 62368-1; CAN/CSA C22.2 No 62368-1; IEC 62368-1; EN 62368-1; AS/NZS 62368-1; FDA 21 CFR Subchapter J; GB 4943.1.
Yes — recorded under "Ethernet features": 802.3x traffic control and half-duplex backpressure; Green Ethernet (EEE); Automatic port energy-saving.
-5℃ ~ 50℃(normal operating temperature); -5℃ ~ 45℃(When using transceiver modules with maximum transmission distance < 80km); -5℃ ~ 40℃(When using transceiver modules with maximum transmission distance ≥ 80km) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Layer 2 Gigabit access switch with PoE+ ports

H3C Gigabit Access Web Managed Switch Series

H3C Series Intelligent Gigabit Access Switches

H3C Series Enhanced Gigabit Access Switches

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S1850V2-EI |
| Manufacturer | H3C |
Campus Access Switches
Fully managed 48-port 1G PoE+ switch with 2 10G and 2 SFP+ ports · Ref. : GSM4352PB
Price on request
Campus Access Switches
Industrial Gigabit managed PoE switch with SFP ports · Ref. : DIS-300G-8PSW
Price on request
Campus Access Switches
Layer 2 PoE campus access switch, 5 ports
Price on request
Campus Access Switches
Multi-gigabit managed switch with 8x 2.5G ports and 10G SFP+ ports · Ref. : GWN7721
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details