S5170-EI
Intelligent Gigabit access switch, 24 PoE+ ports, 4 SFP+ 10G ports

- Power consumption; (Full configuration)
- 37W
- Flash
- 512M
- Operating/Storage Humidity
- 5% RH to 95% RH, non-condensing
- SDRAM
- 1G
Intelligent Gigabit access switch, 24 PoE+ ports, 4 SFP+ 10G ports
The H3C S5170-EI is an intelligent Gigabit Ethernet switch for enterprise and campus access and aggregation layers, with PoE+ power and 10 Gigabit uplink ports.
Overview. The H3C S5170-EI is an intelligent Gigabit Ethernet Layer 2 switch from the H3C S5170-EI series, designed for the access and aggregation layers of enterprise and campus networks. It supports IPv4/IPv6 dual-stack management and forwarding, with static routing and RIP and OSPF routing protocols.
Main characteristics. The switch provides 17 or more Ethernet ports, including 24 or 48 10/100/1000BASE-T ports depending on the model, and 4 or 6 1G/10G BASE-X SFP+ ports. System switching capacity reaches 598 Gbps, port switching capacity 128 Gbps and forwarding capacity 96 Mpps. The processor is a 1 GHz dual-core CPU, with 1 GB SDRAM and 512 MB flash memory.
Interfaces and connectivity. The SFP+ ports accept 1000BASE-SX, 1000BASE-LX, 1000BASE-LH40, 1000BASE-LH80, 1000BASE-LH100 and 1000BASE-T modules, as well as 10G SFP+ modules. Stacking uses standard Ethernet interfaces, with a maximum stacking bandwidth of 80 Gbps. The switch supports management through CLI, Telnet, console port, SNMPv1/v2c/v3, Restful and Python, as well as port aggregation and Layer 2 ring protocols (STP, RSTP, MSTP, G.8032 ERPS, RRPP, Smart Link).
Power and environment. Mains input 100 V to 240 V AC, 50/60 Hz, power consumption of 37 W in full configuration. Operating temperature from -5 °C to 50 °C depending on the optical transceivers used, and storage temperature from -40 °C to +70 °C. Dimensions 440 × 160 × 43.6 mm, weight up to 2.2 kg.
Typical uses. High-density Gigabit network access for user workstations, with PoE+ power for connected devices, and aggregation layer of an enterprise network. Security features include Layer 2 to Layer 4 ACLs, IP Source Guard, IEEE 802.1X authentication, AAA, RADIUS and SSH2.0. Quality of service includes port rate limiting, eight output queues per port and SP and WRR scheduling.
Integration. The switch can act as the management device for SmartMC, a tool for centralised management of small switch fleets, and integrates with other H3C network solutions. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S5170-EI, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| ACL | Packet filtering at Layer 2 through layer 4 Traffic classification based on source MAC addresses, destination MAC addresses, source IPv4/IPv6 addresses,; Time range-based ACL; VLAN-based ACL; Bidirectional ACL |
| Broadcast/Multicast/Unicast storm suppression | Storm suppression based on port bandwidth percentage; Storm suppression based on PPS; Storm suppression based on BPS; Broadcast traffic/Multicast traffic/Unknown unicast traffic suppression |
| Buffer(byte) | 2M |
| CPU | 1GHz, 2Cores |
| DHCP | DHCP Client; DHCP Snooping; DHCP Snooping option82; DHCP Relay; DHCP Server; DHCP auto-config |
| Dimensions (W/D/H) | 440mm×160mm ×43.6mm |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI-CISPR 32 CLASS A; EN 55032 CLASS; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386; GB/T 9254; YD/T 993 |
| Entries | S5170-EI Series Switches |
| Flash | 512M |
| Forwarding Capacity | 96Mpps |
| IEEE | 802.1x Port based network access control protocol |
| IETF | RFC 768 User Datagram Protocol |
| Input Voltage | AC:; Rated voltage range: 100V~240V AC, 50/60Hz; Max voltage range: 90V~ 264V AC, 47~63HZ |
| IP Routing | Static routing; RIPv1/v2 and RIPng; OSPFv1/v2 and OSPFv3; IS-IS |
| IPv4 ACL entries | VFP:512; Ingress:1280; Egress:512 |
| IPv6 ACL entries | VFP:512; Ingress:1280; Egress:512 |
| IRF2 | Distributed device management, distributed link aggregation, and distributed resilient routing; Stacking through standard Ethernet interfaces; Local device stacking and remote device stacking |
| ITU | ITU-T Y.1731 |
| Layer 2 Ring Network Protocol | STP/RSTP/MSTP/PVST/PVST+; Smart Link; RRPP; G.8032 ERPS (Ethernet Ring Protection Switching) |
| LS-5170-28S-EI-GL | H3C S5170-28S-EI L2 Ethernet Switch with 24*10/100/1000BASE-T Ports and 4*1G/10G BASE-X SFP Plus Ports,(AC) |
| LS-5170-28S-HPWR-EI-GL | H3C S5170-28S-HPWR-EI L2 Ethernet Switch with 24*10/100/1000BASE-T Ports and 4*1G/10G BASE-X SFP Plus Ports,(AC),POE+ |
| LS-5170-54S-EI-GL | H3C S5170-54S-EI L2 Ethernet Switch with 48*10/100/1000BASE-T Ports and 6*1G/10G BASE-X SFP Plus Ports,(AC) |
| LS-5170-54S-PWR-EI-GL | H3C S5170-54S-PWR-EI L2 Ethernet Switch with 48*10/100/1000BASE-T Ports and 6*1G/10G BASE-X SFP Plus Ports,(AC),POE+ |
| LSTM1STK | SFP+ Cable 5m |
| LSWM1STK | SFP+ Cable 0.65m |
| LSWM2STK | SFP+ Cable 1.2m |
| LSWM3STK | SFP+ Cable 3m |
| MAC Address Table | Static MAC address; Blackhole MAC address |
| Management and maintenance | Loading and upgrading through XModem/FTP/TFTP; Zero Touch Provisioning; Configuration through CLI, Telnet, and console port; SNMPv1/v2c/v3 and Web-based NMS; Restful; Python; Remote monitoring (RMON) alarm, event, and history recording; IMC NMS; System log, alarming based on severities, and output of debugging information; NTP; Ping, Tracert; Virtual cable test (VCT); Device link detection protocol (DLDP); Loopback-detection |
| Max Stacking Bandwidth | 80Gbps |
| Mirroring | Port mirroring; RSPAN |
| MTBF(year) | 105.515 |
| Multicast | IGMPv1/IGMPv2/IGMPv3; IGMP Snooping V2/V3; MLD Snooping; Multicast VLAN; PIM-SM/PIM-SSM/PIM-DM; MSDP |
| Operating/Storage Humidity | 5% RH to 95% RH, non-condensing |
| Operating Temperature | -5℃ ~ 50℃(Normal operating temperature); -5℃ ~ 45℃(When using transceiver modules with transmission distance between 20km and 80km); -5℃ ~ 40℃(When using transceiver modules with maximum transmission distance ≥ 80km) |
| Organization | Standards And Protocols |
| Port Aggregation | GE/10GE port aggregation; Dynamic aggregation; Static aggregation; Cross-device aggregation |
| Port Switching capacity(bps) | 128Gbps |
| Power consumption; (Full configuration) | 37W |
| Product ID | Product Description |
| QoS | Port rate limit (receiving and transmitting); Packet redirection; Committed access rate (CAR); Eight output queues on each port; Flexible queue scheduling algorithms based on ports and queues, including SP, WRR and SP+WRR; 802.1p DSCP remarking |
| S5170-28S-HPWR-EI — 370W | 15.4W (802.3af): 24; 30W (802.3at): 12; 35W: 10 |
| S5170-54S-PWR-EI — 370W | 15.4W (802.3af): 24; 30W (802.3at): 12; 35W: 10 |
| Safety | CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| SDRAM | 1G |
| Security | Hierarchical user management and password protection; AAA authentication support; RADIUS authentication; HWTACACS; SSH2.0; Port isolation; 802.1X authentication, centralized MAC authentication; Port security; Flow control; IP Source Guard; HTTPs; EAD |
| SFP-GE-LH100-SM1550 | 1000BASE-LH100 SFP Transceiver, Single Mode (1550nm, 100km, LC) |
| SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| SFP-GE-T | 1000BASE-T SFP |
| SFP-XG-LX-SM1310-E | SFP+ Module(1310nm,10km,LC) |
| SFP-XG-SX-MM850-E | SFP+ Module(850nm,300m,LC) |
| Storage Temperature | -40~+70℃ |
| System Switching Capacity(bps) | 598Gbps |
| Traffic statistic | sFlow |
| VLAN | Port-based VLAN; MAC-based VLAN; Protocol-based VLAN; QinQ and selective QinQ; VLAN mapping; Voice VLAN/Private VLAN/Super VLAN; GVRP |
| Weight | ≤2.2kg |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S5170-EI. For a missing document or a specific revision, our experts send it to you.
The H3C S5170-EI is an intelligent Gigabit Ethernet switch for enterprise and campus access and aggregation layers, with PoE+ power and 10 Gigabit uplink ports.
| Parameter | Value |
|---|---|
| ACL | Packet filtering at Layer 2 through layer 4 Traffic classification based on source MAC addresses, destination MAC addresses, source IPv4/IPv6 addresses,; Time range-based ACL; VLAN-based ACL; Bidirectional ACL |
| Broadcast/Multicast/Unicast storm suppression | Storm suppression based on port bandwidth percentage; Storm suppression based on PPS; Storm suppression based on BPS; Broadcast traffic/Multicast traffic/Unknown unicast traffic suppression |
| Buffer(byte) | 2M |
| CPU | 1GHz, 2Cores |
| DHCP | DHCP Client; DHCP Snooping; DHCP Snooping option82; DHCP Relay; DHCP Server; DHCP auto-config |
| Dimensions (W/D/H) | 440mm×160mm ×43.6mm |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI-CISPR 32 CLASS A; EN 55032 CLASS; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386; GB/T 9254; YD/T 993 |
| Entries | S5170-EI Series Switches |
| Flash | 512M |
| Forwarding Capacity | 96Mpps |
| IEEE | 802.1x Port based network access control protocol |
| IETF | RFC 768 User Datagram Protocol |
| Input Voltage | AC:; Rated voltage range: 100V~240V AC, 50/60Hz; Max voltage range: 90V~ 264V AC, 47~63HZ |
| IP Routing | Static routing; RIPv1/v2 and RIPng; OSPFv1/v2 and OSPFv3; IS-IS |
| IPv4 ACL entries | VFP:512; Ingress:1280; Egress:512 |
| IPv6 ACL entries | VFP:512; Ingress:1280; Egress:512 |
| IRF2 | Distributed device management, distributed link aggregation, and distributed resilient routing; Stacking through standard Ethernet interfaces; Local device stacking and remote device stacking |
| ITU | ITU-T Y.1731 |
| Layer 2 Ring Network Protocol | STP/RSTP/MSTP/PVST/PVST+; Smart Link; RRPP; G.8032 ERPS (Ethernet Ring Protection Switching) |
| LS-5170-28S-EI-GL | H3C S5170-28S-EI L2 Ethernet Switch with 24*10/100/1000BASE-T Ports and 4*1G/10G BASE-X SFP Plus Ports,(AC) |
| LS-5170-28S-HPWR-EI-GL | H3C S5170-28S-HPWR-EI L2 Ethernet Switch with 24*10/100/1000BASE-T Ports and 4*1G/10G BASE-X SFP Plus Ports,(AC),POE+ |
| LS-5170-54S-EI-GL | H3C S5170-54S-EI L2 Ethernet Switch with 48*10/100/1000BASE-T Ports and 6*1G/10G BASE-X SFP Plus Ports,(AC) |
| LS-5170-54S-PWR-EI-GL | H3C S5170-54S-PWR-EI L2 Ethernet Switch with 48*10/100/1000BASE-T Ports and 6*1G/10G BASE-X SFP Plus Ports,(AC),POE+ |
| LSTM1STK | SFP+ Cable 5m |
| LSWM1STK | SFP+ Cable 0.65m |
| LSWM2STK | SFP+ Cable 1.2m |
| LSWM3STK | SFP+ Cable 3m |
| MAC Address Table | Static MAC address; Blackhole MAC address |
| Management and maintenance | Loading and upgrading through XModem/FTP/TFTP; Zero Touch Provisioning; Configuration through CLI, Telnet, and console port; SNMPv1/v2c/v3 and Web-based NMS; Restful; Python; Remote monitoring (RMON) alarm, event, and history recording; IMC NMS; System log, alarming based on severities, and output of debugging information; NTP; Ping, Tracert; Virtual cable test (VCT); Device link detection protocol (DLDP); Loopback-detection |
| Max Stacking Bandwidth | 80Gbps |
| Mirroring | Port mirroring; RSPAN |
| MTBF(year) | 105.515 |
| Multicast | IGMPv1/IGMPv2/IGMPv3; IGMP Snooping V2/V3; MLD Snooping; Multicast VLAN; PIM-SM/PIM-SSM/PIM-DM; MSDP |
| Operating/Storage Humidity | 5% RH to 95% RH, non-condensing |
| Operating Temperature | -5℃ ~ 50℃(Normal operating temperature); -5℃ ~ 45℃(When using transceiver modules with transmission distance between 20km and 80km); -5℃ ~ 40℃(When using transceiver modules with maximum transmission distance ≥ 80km) |
| Organization | Standards And Protocols |
| Port Aggregation | GE/10GE port aggregation; Dynamic aggregation; Static aggregation; Cross-device aggregation |
| Port Switching capacity(bps) | 128Gbps |
| Power consumption; (Full configuration) | 37W |
| Product ID | Product Description |
| QoS | Port rate limit (receiving and transmitting); Packet redirection; Committed access rate (CAR); Eight output queues on each port; Flexible queue scheduling algorithms based on ports and queues, including SP, WRR and SP+WRR; 802.1p DSCP remarking |
| S5170-28S-HPWR-EI — 370W | 15.4W (802.3af): 24; 30W (802.3at): 12; 35W: 10 |
| S5170-54S-PWR-EI — 370W | 15.4W (802.3af): 24; 30W (802.3at): 12; 35W: 10 |
| Safety | CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| SDRAM | 1G |
| Security | Hierarchical user management and password protection; AAA authentication support; RADIUS authentication; HWTACACS; SSH2.0; Port isolation; 802.1X authentication, centralized MAC authentication; Port security; Flow control; IP Source Guard; HTTPs; EAD |
| SFP-GE-LH100-SM1550 | 1000BASE-LH100 SFP Transceiver, Single Mode (1550nm, 100km, LC) |
| SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| SFP-GE-T | 1000BASE-T SFP |
| SFP-XG-LX-SM1310-E | SFP+ Module(1310nm,10km,LC) |
| SFP-XG-SX-MM850-E | SFP+ Module(850nm,300m,LC) |
| Storage Temperature | -40~+70℃ |
| System Switching Capacity(bps) | 598Gbps |
| Traffic statistic | sFlow |
| VLAN | Port-based VLAN; MAC-based VLAN; Protocol-based VLAN; QinQ and selective QinQ; VLAN mapping; Voice VLAN/Private VLAN/Super VLAN; GVRP |
| Weight | ≤2.2kg |
Answers to the questions that the recorded characteristics of S5170-EI can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Safety": CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1.
Yes — recorded under "IRF2": Distributed device management, distributed link aggregation, and distributed resilient routing; Stacking through standard Ethernet interfaces; Local device stacking and remote device stacking.
-5℃ ~ 50℃(Normal operating temperature); -5℃ ~ 45℃(When using transceiver modules with transmission distance between 20km and 80km); -5℃ ~ 40℃(When using transceiver modules with maximum transmission distance ≥ 80km) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Intelligent Gigabit access switch, 24 PoE+ ports, 4 SFP+ 10G ports

H3C Layer 2 Gigabit Access Switch Series

H3C Series Enhanced Gigabit Access Switches

H3C Series Enhanced Gigabit Access Switches

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S5170-EI |
| Manufacturer | H3C |
Campus Access Switches
Fully managed 48-port 1G PoE+ switch with 2 10G and 2 SFP+ ports · Ref. : GSM4352PB
Price on request
Campus Access Switches
Industrial Gigabit managed PoE switch with SFP ports · Ref. : DIS-300G-8PSW
Price on request
Campus Access Switches
Layer 2 PoE campus access switch, 5 ports
Price on request
Campus Access Switches
Multi-gigabit managed switch with 8x 2.5G ports and 10G SFP+ ports · Ref. : GWN7721
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details