S6530X
10GE Aggregation Layer 3 Switch with SFP+ and QSFP28 Ports

- Operating Temperature
- -5ºC to 45ºC (23ºF to 113ºF)
- Interface number per VRF
- 4K
- Flash
- 4GB
- Operating/Storage Humidity
- 5% RH to 95% RH, non-condensing
10GE Aggregation Layer 3 Switch with SFP+ and QSFP28 Ports
H3C S6530X Layer 3 aggregation switch with 10GE SFP+ and 100GE QSFP28 ports, designed for campus aggregation and core layers, with 4.8 Tbps switching capacity.
H3C S6530X. The H3C S6530X aggregation switch is a high-density 10GE Layer 3 Ethernet switch available in a 24 SFP+ port version and a 48 SFP+ port version, both equipped with 8 QSFP28 ports supporting 40GE/100GE. The manufacturer presents it as a scalable aggregation solution with OSPF, BGP, multicast and flexible management.
Performance. Switching capacity of 4.8 Tbps, port switching capacity of 2.08 Tbps and packet forwarding rate of 1560 Mpps, with hardware-based wire-speed/line-rate forwarding. The CPU is a quad-core 2 GHz processor, flash and SDRAM are 4 GB each, and the packet buffer is 36 MB. Latency is below 3 µs (64 bytes) on 10GE and below 1.2 µs on 100GE.
Tables and routing. MAC address table of 576K entries, 768K IPv4 routing entries and 144K IPv6 unicast routing entries. Static routing, RIP, OSPF, IS-IS and BGP with IPv4/IPv6 dual stack, ECMP, PBR and routing policy. Supports VXLAN, EVPN, MPLS (LDP, L2VPN, L3VPN, SRv6) and 4K VRF instances.
Multicast and QoS. PIM-DM, PIM-SM, PIM-SSM, IGMPv1/v2/v3 and MLDv1/v2 with snooping, MVPN and multicast QoS. Intelligent lossless network with PFC, ECN and IPCC.
Connectivity and aggregation. Static and dynamic link aggregation, LACP, M-LAG and S-MLAG, 10GE/25G/40GE/100GE port aggregation, 802.1x, OpenFlow 1.3 and inband telemetry (INT). One RJ45 console port and one RJ45 out-of-band management port are provided.
Stacking. Intelligent Resilient Framework 2 (IRF2), with fast convergence within 50 ms, distributed device management, distributed link aggregation and distributed resilient routing, up to 800 Gbps of stacking bandwidth. Stacking can run over standard Ethernet ports.
Power and environment. AC input of 100 to 240 VAC at 50/60 Hz (max range 90 to 264 VAC), hot-swappable 250 W AC or 450 W DC power supply modules, and 5 hot-swappable fan trays with invertible airflow. Power consumption is 76 W with a single power input and 83 W with dual power inputs. Operating temperature from -5 °C to 45 °C, humidity from 5% to 95% non-condensing. Weight of 7.3 kg or less, dimensions 44 × 440 × 400 mm.
Typical uses. Campus aggregation and core layers, data centres, with automation through Ansible, Python, NETCONF and RESTful/RESTCONF APIs. The product is available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S6530X, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Automatic Configuration | Server-based automatic configuration; USB-based automatic configuration |
| Box Switching capacity | 4.8Tbps |
| Console Ports | 1 RJ45 |
| CPU | Quad core, 2GHz |
| Dimensions H*W*D | 44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in) |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; CISPR 35; AS/NZS CISPR 32; EN 55035; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386 |
| Ethernet configuration | Static aggregation; Dynamic aggregation; 10GE/25G/40GE/100GE port aggregation; LACP (Link Aggregation Control Protocol); S-MLAG; M-LAG (Multichassis Link Aggregation); AutoMDIX; Duplex Auto/Full/Half |
| Fan — LSPM1FANSA-SN | H3C Fan Module (Fan Panel Side Intake Airflow) |
| Fan — LSPM1FANSB-SN | H3C Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan trays | 5 hot swappable fan trays, invertible airflow |
| Flash | 4GB |
| Forwarding | Hardware-based (ASlC)Wire-speed/Line-rate architecture |
| IEEE | 802.1x Port based network access control protocol |
| IETF | RFC 1213 MIB-2 Stands for Management Information Base |
| Input voltage range | AC:; Rated: 100 VAC to 240 VAC @ 50 Hz/60 Hz; Max: 90 VAC to 264 VAC @ 47 Hz to 63 Hz |
| Intelligent Lossless Network | PFC (Priority-based Flow Control); ECN (Explicit Congestion Notification); IPCC (Intelligent Proactive Congestion Control); iNOF (Intelligent Lossless NVMe Over Fabric) |
| Interface number per VRF | 4K |
| IPv4 ACL entries | Ingress: 26K; Egress: 2K |
| IPv4 ARP entries(max) | 94K |
| IPv4 multicast L2 entries | 8K |
| IPv4 multicast L3 entries | 8K |
| IPv4 routing entries(max) | 768K |
| IPv6 ACL entries | Ingress: 13K; Egress: 1K |
| IPv6 multicast L2 entries | 8K |
| IPv6 multicast L3 entries | 8K |
| IPv6 ND entries(max) | 48K |
| IPv6 unicast routing entries(max) | 144K |
| ITU | ITU-T Y.1731 |
| Latency | 10GE:<3 (64byte/us); 100GE:<1.2 (64byte/us) |
| MAC address entries(max) | 576K |
| Management Ethernet ports | 1 RJ45 (Out of Band) |
| Max Stacking Bandwidth | 800Gbps |
| MPLS | Static LSP (label switched path); LDP (Label Distribution Protocol); IPv6 LDP; Tunnel policies; VRF; MPLS L2VPN; MPLS L3VPN; MPLS Ping/Tracert; MCE (Multi-VPN Instance Customer Edge); IPv6 MCE; MPLS OAM; SRv6 |
| Multicast | PIM-DM, PIM-SM, PIM-SSM, and Any-RP; PIM snooping; MSDP (Multicast Source Discovery Protocol); IGMPv1/IGMPv2/IGMPv3; IGMP proxying; IGMP Snooping; IGMP snooping proxying; IGMP Filter and IGMP Fast leave; IPv6 PIM-DM, PIM-SM, PIM-SSM, and Any-RP; IPv6 PIM snooping; MLDv1/MLDV2; MLD proxying; MLD Snooping; MLD snooping proxying; Multicast routing and forwarding; Multicast VLAN; MVPN (Multicast VPN); Multicast policy and Multicast QoS |
| OpenFlow | OpenFlow 1.3; Multiple controllers (EQUAL, master/slave); Multiple tables flow; Group table |
| Operating/Storage Humidity | 5% RH to 95% RH, non-condensing |
| Operating Temperature | -5ºC to 45ºC (23ºF to 113ºF) |
| Organization | Standards and protocols |
| Packet Buffer | 36M |
| Packet Forwarding Rate | 1560Mpps |
| Port Switching Capacity | 2.08Tbps |
| Power consumption | MIN:; Single Power Input: 76W; Dual Power Input: 83W. |
| Power supply — PSR250-12A | 250W AC Power Supply Module (Power Panel Side Intake Airflow) |
| Power supply — PSR250-12A1 | 250W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Product code — LS-6530X-24X8C | H3C S6530X-24X8C L3 Ethernet Switch with 24*SFP+ Ports,8*QSFP28 Ports,Without Power Supplies |
| Product code — LS-6530X-48X8C | H3C S6530X-48X8C L3 Ethernet Switch with 48*SFP+ Ports,8*QSFP28 Ports,Without Power Supplies |
| Programmability and Automation | Ansible; Auto DevOps by using Python, NETCONF, TCL, and RESTful/RESTconf API for automated network programming |
| Removable fan trays | Supported (Fan Panel Side Exhaust Airflow) |
| Removable power supplies | Supported (Power Panel Side Exhaust Airflow) |
| RoHS | EU RoHS2.0 Directive; China RoHS 2.0 |
| Routing | Static routing, RIP, OSPF, IS-IS, and BGP; IPv4/IPv6 dual stack; IPv4/IPv6 ECMP (Equal-cost multi-path routing); IPv4/IPv6 PBR (Policy-based routing); IPv4/IPv6 Routing policy; IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+; Pingv6, Telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6; Dual-stack PBR |
| Safety | UL 62368-1; CSA C22.2 No. 62368-1-14; IEC 62368-1; EN 62368-1; EN 60825-1; AS/NZS 62368-1; GB 4943.1 |
| SDRAM | 4GB |
| Stacking | Intelligent Resilient Framework 2 (IRF2) (fast convergence within 50ms); Distributed device management; Distributed link aggregation; Distributed resilient routing; Stacking through standard Ethernet ports; Local device stacking and remote device stacking; LACP-, BFD-, and ARP-based multi-active detection (MAD) |
| Storage Temperature | -40ºC to 70ºC(-40ºF to 158ºF) |
| Visualization | gRPC (Google remote procedure call); INT (Inband Telemetry); Flow group |
| VRF number | 4K |
| VXLAN | VXLAN L2 switching; VXLAN L3 routing; Centralized VXLAN gateway; Distributed VXLAN gateway; VXLAN M-LAG; VXLAN-DCI; OVSDB (Open vSwitch Database); VXLAN VTEP; MP-BGP EVPN control plane; EVPN VXLAN; EVPN M-LAG |
| Weight | ≤ 7.3 kg |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S6530X. For a missing document or a specific revision, our experts send it to you.
H3C S6530X Layer 3 aggregation switch with 10GE SFP+ and 100GE QSFP28 ports, designed for campus aggregation and core layers, with 4.8 Tbps switching capacity.
| Parameter | Value |
|---|---|
| Automatic Configuration | Server-based automatic configuration; USB-based automatic configuration |
| Box Switching capacity | 4.8Tbps |
| Console Ports | 1 RJ45 |
| CPU | Quad core, 2GHz |
| Dimensions H*W*D | 44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in) |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; CISPR 35; AS/NZS CISPR 32; EN 55035; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386 |
| Ethernet configuration | Static aggregation; Dynamic aggregation; 10GE/25G/40GE/100GE port aggregation; LACP (Link Aggregation Control Protocol); S-MLAG; M-LAG (Multichassis Link Aggregation); AutoMDIX; Duplex Auto/Full/Half |
| Fan — LSPM1FANSA-SN | H3C Fan Module (Fan Panel Side Intake Airflow) |
| Fan — LSPM1FANSB-SN | H3C Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan trays | 5 hot swappable fan trays, invertible airflow |
| Flash | 4GB |
| Forwarding | Hardware-based (ASlC)Wire-speed/Line-rate architecture |
| IEEE | 802.1x Port based network access control protocol |
| IETF | RFC 1213 MIB-2 Stands for Management Information Base |
| Input voltage range | AC:; Rated: 100 VAC to 240 VAC @ 50 Hz/60 Hz; Max: 90 VAC to 264 VAC @ 47 Hz to 63 Hz |
| Intelligent Lossless Network | PFC (Priority-based Flow Control); ECN (Explicit Congestion Notification); IPCC (Intelligent Proactive Congestion Control); iNOF (Intelligent Lossless NVMe Over Fabric) |
| Interface number per VRF | 4K |
| IPv4 ACL entries | Ingress: 26K; Egress: 2K |
| IPv4 ARP entries(max) | 94K |
| IPv4 multicast L2 entries | 8K |
| IPv4 multicast L3 entries | 8K |
| IPv4 routing entries(max) | 768K |
| IPv6 ACL entries | Ingress: 13K; Egress: 1K |
| IPv6 multicast L2 entries | 8K |
| IPv6 multicast L3 entries | 8K |
| IPv6 ND entries(max) | 48K |
| IPv6 unicast routing entries(max) | 144K |
| ITU | ITU-T Y.1731 |
| Latency | 10GE:<3 (64byte/us); 100GE:<1.2 (64byte/us) |
| MAC address entries(max) | 576K |
| Management Ethernet ports | 1 RJ45 (Out of Band) |
| Max Stacking Bandwidth | 800Gbps |
| MPLS | Static LSP (label switched path); LDP (Label Distribution Protocol); IPv6 LDP; Tunnel policies; VRF; MPLS L2VPN; MPLS L3VPN; MPLS Ping/Tracert; MCE (Multi-VPN Instance Customer Edge); IPv6 MCE; MPLS OAM; SRv6 |
| Multicast | PIM-DM, PIM-SM, PIM-SSM, and Any-RP; PIM snooping; MSDP (Multicast Source Discovery Protocol); IGMPv1/IGMPv2/IGMPv3; IGMP proxying; IGMP Snooping; IGMP snooping proxying; IGMP Filter and IGMP Fast leave; IPv6 PIM-DM, PIM-SM, PIM-SSM, and Any-RP; IPv6 PIM snooping; MLDv1/MLDV2; MLD proxying; MLD Snooping; MLD snooping proxying; Multicast routing and forwarding; Multicast VLAN; MVPN (Multicast VPN); Multicast policy and Multicast QoS |
| OpenFlow | OpenFlow 1.3; Multiple controllers (EQUAL, master/slave); Multiple tables flow; Group table |
| Operating/Storage Humidity | 5% RH to 95% RH, non-condensing |
| Operating Temperature | -5ºC to 45ºC (23ºF to 113ºF) |
| Organization | Standards and protocols |
| Packet Buffer | 36M |
| Packet Forwarding Rate | 1560Mpps |
| Port Switching Capacity | 2.08Tbps |
| Power consumption | MIN:; Single Power Input: 76W; Dual Power Input: 83W. |
| Power supply — PSR250-12A | 250W AC Power Supply Module (Power Panel Side Intake Airflow) |
| Power supply — PSR250-12A1 | 250W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Product code — LS-6530X-24X8C | H3C S6530X-24X8C L3 Ethernet Switch with 24*SFP+ Ports,8*QSFP28 Ports,Without Power Supplies |
| Product code — LS-6530X-48X8C | H3C S6530X-48X8C L3 Ethernet Switch with 48*SFP+ Ports,8*QSFP28 Ports,Without Power Supplies |
| Programmability and Automation | Ansible; Auto DevOps by using Python, NETCONF, TCL, and RESTful/RESTconf API for automated network programming |
| Removable fan trays | Supported (Fan Panel Side Exhaust Airflow) |
| Removable power supplies | Supported (Power Panel Side Exhaust Airflow) |
| RoHS | EU RoHS2.0 Directive; China RoHS 2.0 |
| Routing | Static routing, RIP, OSPF, IS-IS, and BGP; IPv4/IPv6 dual stack; IPv4/IPv6 ECMP (Equal-cost multi-path routing); IPv4/IPv6 PBR (Policy-based routing); IPv4/IPv6 Routing policy; IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+; Pingv6, Telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6; Dual-stack PBR |
| Safety | UL 62368-1; CSA C22.2 No. 62368-1-14; IEC 62368-1; EN 62368-1; EN 60825-1; AS/NZS 62368-1; GB 4943.1 |
| SDRAM | 4GB |
| Stacking | Intelligent Resilient Framework 2 (IRF2) (fast convergence within 50ms); Distributed device management; Distributed link aggregation; Distributed resilient routing; Stacking through standard Ethernet ports; Local device stacking and remote device stacking; LACP-, BFD-, and ARP-based multi-active detection (MAD) |
| Storage Temperature | -40ºC to 70ºC(-40ºF to 158ºF) |
| Visualization | gRPC (Google remote procedure call); INT (Inband Telemetry); Flow group |
| VRF number | 4K |
| VXLAN | VXLAN L2 switching; VXLAN L3 routing; Centralized VXLAN gateway; Distributed VXLAN gateway; VXLAN M-LAG; VXLAN-DCI; OVSDB (Open vSwitch Database); VXLAN VTEP; MP-BGP EVPN control plane; EVPN VXLAN; EVPN M-LAG |
| Weight | ≤ 7.3 kg |
Points to check before using S6530X in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Input voltage range | AC:; Rated: 100 VAC to 240 VAC @ 50 Hz/60 Hz; Max: 90 VAC to 264 VAC @ 47 Hz to 63 Hz |
| Power consumption | MIN:; Single Power Input: 76W; Dual Power Input: 83W. |
| Power supply — PSR250-12A | 250W AC Power Supply Module (Power Panel Side Intake Airflow) |
| Power supply — PSR250-12A1 | 250W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Removable power supplies | Supported (Power Panel Side Exhaust Airflow) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of S6530X can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Ethernet configuration": Static aggregation; Dynamic aggregation; 10GE/25G/40GE/100GE port aggregation; LACP (Link Aggregation Control Protocol); S-MLAG; M-LAG (Multichassis Link Aggregation); AutoMDIX; Duplex Auto/Full/Half.
Yes — recorded under "Automatic Configuration": Server-based automatic configuration; USB-based automatic configuration.
-5ºC to 45ºC (23ºF to 113ºF) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
10GE Aggregation Layer 3 Switch with SFP+ and QSFP28 Ports

H3C Series Enhanced 10GE Switches

30 Port SFP+ Layer 3 Managed Industrial Ethernet Switch

Layer 3 10GBASE-X SFP+ + 4-Port 10GBASE-T Managed Ethernet Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S6530X |
| Manufacturer | H3C |
Core and Aggregation Switches
Gigabit Managed Layer 3 Switch with 4 SFP Ports · Ref. : DGS-3312SR
Price on request
Core and Aggregation Switches
24-port Layer 3 PoE+ switch with 2.5 GbE and 10G SFP+ · Ref. : USW-ENTERPRISE-24-POE
Price on request
Core and Aggregation Switches
IP65 high bay dual sense presence sensor HF and PIR · Ref. : HIM30-B-L2
Price on request
Core and Aggregation Switches
28-port GbE L3 aggregation switch with 4 SFP+ uplinks
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details