S6805
Data center L3 switch with 48 10G SFP+ and 6 100G QSFP28 ports

- Operating Temperature
- 0°C to 45°C (32°F to 113°F)
- Interface — IPv4 tunnel number
- 2K
- Interface — IPv6 tunnel number
- 2K
- Interface — Loopback interface number
- 1K
Data center L3 switch with 48 10G SFP+ and 6 100G QSFP28 ports
H3C S6805 L3 switch for data centers and cloud networks, with 48 10G SFP+ and 6 100G QSFP28 ports, used for high-density server access or as a TOR switch.
Overview. The H3C S6805-54HF is a Layer 3 Ethernet switch designed for data centers and cloud computing networks, and it can also operate as a TOR access switch. It is available in the S6805-54HF version (48 10G SFP+ ports) and the S6805-54HT version (48 10G BASE-T ports), both with 6 100G QSFP28 ports.
Main characteristics. Forwarding capacity of 1001.7 Mpps, latency below 800 ns (64 byte), 32M buffer, and 4G/8G Flash/SDRAM. The MAC table holds up to 288K entries and the IPv4 unicast route table up to 324K entries.
Interfaces and connectivity. 48 10G SFP+ ports and 6 100G QSFP28 ports, one GE copper and one GE fiber out-of-band management port, with optional 40G QSFP+, 100G QSFP28 and SFP+ cables. Configuration and maintenance are done through console, Telnet and SSH terminals. The switch supports IPv4 and IPv6 static and default routing, IGMP snooping multicast, VPN and MPLS/VPLS (L3 MPLS VPN).
Virtualization and data center features. Device virtualization with IRF2.0 into one logical device, VXLAN, MP-BGP EVPN as the VXLAN control plane, and FCoE. PFC, ECN and DCBX provide a lossless network for RDMA applications and high-performance computing services.
Power and environment. AC input of 90 V to 290 V or DC input of –36 V to –72 V depending on the module, maximum power consumption of 202 W to 217 W depending on configuration, 5 hot-swappable fans with 3+2 redundancy and reversible airflow, operating temperature of 0 °C to 45 °C and humidity of 5% RH to 95% RH, noncondensing. MTBF of 35.4 years. Dimensions 44 × 440 × 400 mm.
Typical uses. High-density 10G server access in data centers, TOR switch deployment on an overlay or integrated network, and FCoE storage networks.
Integration. Supports IEEE 802.1Q, 802.1w, 802.1s, 802.1X and 802.1Qbb, with Class A EMC compliance (FCC, CISPR 32, EN 55032, among others).
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S6805, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC input voltage | 90v AC to 290v AC |
| ACL — max number of egress Car | 1K |
| ACL — max number of egress Counter | 1K |
| ACL — max number of ingress ACL | 18K |
| Air flow direction | From front to rear or from rear to front |
| Buffer | 32M |
| Cable — LSTM1STK | SFP+ Cable 5m |
| Cable — LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| Cable — LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| Cable — LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| Cable — LSWM1QSTK3 | 40G QSFP+ to 4x10G SFP+ Cable 1m |
| Cable — LSWM1QSTK4 | 40G QSFP+ to 4x10G SFP+ Cable 3m |
| Cable — LSWM1QSTK5 | 40G QSFP+ to 4x10G SFP+ Cable 5m |
| Cable — LSWM1STK | SFP+ Cable 0.65m |
| Cable — LSWM2STK | SFP+ Cable 1.2m |
| Cable — LSWM3STK | SFP+ Cable 3m |
| Cable — QSFP-100G-4SFP-25G-CAB-1M | 100G QSFP28 to 4x25G SFP28 1m Passive Cable |
| Cable — QSFP-100G-4SFP-25G-CAB-3M | 100G QSFP28 to 4x25G SFP28 3m Passive Cable |
| Cable — QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m AOC |
| Cable — QSFP-100G-D-AOC-20M | 100G QSFP28 to 100G QSFP28 20m AOC |
| Cable — QSFP-100G-D-AOC-7M | 100G QSFP28 to 100G QSFP28 7m AOC |
| Cable — QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| Cable — QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| Cable — QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| Cable — QSFP-40G-D-AOC-10M | 40G QSFP+ to 40G QSFP+10m AOC |
| Cable — QSFP-40G-D-AOC-20M | 40G QSFP+ to 40G QSFP+20m AOC |
| Cable — QSFP-40G-D-AOC-7M | 40G QSFP+ to 40G QSFP+7m AOC |
| Cable — SFP-XG-D-AOC-10M | SFP+ to SFP+10m AOC |
| Cable — SFP-XG-D-AOC-20M | SFP+ to SFP+20m AOC |
| Cable — SFP-XG-D-AOC-7M | SFP+ to SFP+7m AOC |
| Configuration and maintenance | Console telnet and SSH terminals |
| CPU | LS-6805-54HF: C2000,2.4 GHz@4 Cores; LS-6805-54HF-H2: C3000,2.2GHz@4Core |
| DC Input Voltage | –36v DC to –72v DC |
| Device virtualization | IRF2.0 |
| Dimensions H*W*D | 44× 440 × 400 mm; (1.74×17.32×15.74 in) |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386; GB/T 9254; YD/T 993 |
| Fan — LSPM1FANSA | Ethernet Switch Fan Module(Power to Port Airflow) |
| Fan — LSPM1FANSB | Ethernet Switch Fan Module(Port to Power Airflow) |
| Fan tray slot | 5 Hot-swappable fan, fan speed adjustable and wind invertible. (3+2 redundancy) |
| Flash/SDRAM | 4G/8G |
| Forwarding Capacity | 1001.7 Mpps |
| Forwarding table — ECMP group | max 4K |
| Forwarding table — ECMP member per group | 2-128 |
| Forwarding table — IPv4 multicast routing | 128K |
| Forwarding table — IPv6 multicast routing | 64K |
| Forwarding table — max ND table size for IPv6 | 136K max |
| Forwarding table — max number of ARP entries IPv4 | 272K max |
| Forwarding table — max number of MAC per switch | 288K max |
| Forwarding table — max number of unicast routes IPv4 | 324K max |
| Forwarding table — max number of unicast routes IPv6 | 162K max |
| IEEE Standard | 802.3x/802.3ad/802.3AH/802.1P/802.1Q/802.1X/802.1D/802.1w/802.1s/802.1AG; 802.1x/802.1Qbb/802.1az/802.1Qaz |
| Interface — IPv4 tunnel number | 2K |
| Interface — IPv6 tunnel number | 2K |
| Interface — Loopback interface number | 1K |
| Interface — SVI interface number | 2K |
| Interface — VSI interface number | 8K |
| Interface — VxLAN AC number | 16K |
| Interface — VxLAN tunnel number | 2K |
| Interface — VxLAN VSI number | 16K |
| IPv4 routing | Static routing and default routing |
| IPv6 routing | Static routing and default routing |
| Latency | < 800 ns (64 byte) |
| Lossless network | PFC and ECN |
| MAC Address | Dynamic learning and aging of mac address entries |
| Maximum power consumption | PSR250-12A/PSR250-12A1:; · Single AC input: 208 W; · Dual AC inputs: 213 W; PSR450-12A/PSR450-12A1:; · Single AC input: 208 W; · Dual AC inputs: 213 W; PSR450-12AHD:; · Single DC input: 202 W; · Dual DC inputs: 214 W; PSR450-12D:; · Single DC input: 207 W; · Dual DC inputs: 217 W |
| MPLS/VPLS | Support L3 MPLS VPN |
| MTBF(years) | 35.4 |
| Multicast | IGMP snooping |
| Network virtualization | BGP-EVPN |
| Operating humidity (noncondensing) | 5% RH to 95% RH, noncondensing |
| Operating Temperature | 0°C to 45°C (32°F to 113°F) |
| Out-of-band management port | One GE copper port and one GE fiber port |
| Performance — RIB | 500K |
| PID | LS-6805-54HF-H2 |
| PID — LS-6805-54HF-H2 | H3C S6805-54HF L3 Ethernet Switch with 48 SFP Plus Ports and 6 QSFP28 Ports |
| PID — LS-6805-54HT-H2 | H3C S6805-54HT L3 Ethernet Switch with 48 10G BASE-T Ports and 6 QSFP28 Ports |
| Power — PSR450-12A1 | 450W AC Power Supply Module |
| Power — PSR450-12AHD | 450W AC Power Supply Module,Support 240V/336V HVDC Input |
| Power — PSR450-12D | 450W DC Power Supply Module |
| Programmability | Openflow1.3 |
| QoS | Weighted Random Early Detection (WRED) and tail drop |
| Reliability | LACP |
| Safety | UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| SDN | H3C SeerEngine-DC |
| Security and management | Micro-Segmentation |
| Static table — static ARP | 1K |
| Static table — static IPv4 routing table | 2K |
| Static table — static multicast mac-address | 1K |
| Static table — static ND | 4K |
| Switching Capacity | 2.16 Tbps |
| Telemetry | gRPC |
| Traffic analysis | sFlow/NetStream |
| Transceiver — QSFP-100G-ER4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,40km,ER4L,WDM,LC) |
| Transceiver — QSFP-100G-LR4-WDM1300 | 100G QSFP28 Optical Transceiver Module(1310nm,10km,LR4,WDM,LC) |
| Transceiver — QSFP-100G-LR4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,2km,LR4L,CWDM4,LC) |
| Transceiver — QSFP-100G-PSM4-SM1310 | 100G QSFP28 Optical Transceiver Module (1310nm,500m,PSM4,MPO/APC) |
| Transceiver — QSFP-100G-SR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,100m OM4,SR4,MPO) |
| Transceiver — QSFP-100G-ZR4-WDM1300 | 100G QSFP28 Optical Transceiver Module (1300nm,80km,ZR4,WDM,LC) |
| Transceiver — QSFP-40G-BIDI-SR-MM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,100m,SR) |
| Transceiver — QSFP-40G-CSR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,300m,CSR4,Support 40G to 4*10G) |
| Transceiver — QSFP-40G-LR4-PSM1310 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,10km,MPO/APC,LR4,Parallel Single Mode) |
| Transceiver — QSFP-40G-LR4-WDM1300 | 40GBASE-LR4 QSFP+ Optical Transceiver Module |
| Transceiver — QSFP-40G-LR4L-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,2km,LR4L,LC) |
| Transceiver — QSFP-40G-SR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,100m,SR4,Support 40G to 4*10G) |
| Transceiver — SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| Transceiver — SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| Transceiver — SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| Transceiver — SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| Transceiver — SFP-GE-T | 1000BASE-T SFP |
| Transceiver — SFP-XG-LH40-SM1550 | SFP+ Module(1550nm,40km,LC) |
| Transceiver — SFP-XG-LH80-SM1550 | SFP+ Module(1550nm,80km,LC) |
| Transceiver — SFP-XG-LH80-SM1550-D | SFP+ Module(1550nm,80km,LC) |
| Transceiver — SFP-XG-LX-SM1310 | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-LX-SM1310-D | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-LX-SM1310-E | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-SX-MM850-A | SFP+ Module(850nm,300m,LC) |
| Typical Power Consumption | PSR250-12A/PSR250-12A1:; · Single AC input: 120 W; · Dual AC inputs: 127 W; PSR450-12A/PSR450-12A1:; · Single AC input: 120 W; · Dual AC inputs: 127 W PSR450-12D:; · Single DC input: 130 W; · Dual DC inputs: 135 W |
| VLAN | Port-based VLANs |
| VXLAN | L2 VxLAN gateway |
| Weight | ≤ 10 kg (22.04 lb) |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S6805. For a missing document or a specific revision, our experts send it to you.
H3C S6805 L3 switch for data centers and cloud networks, with 48 10G SFP+ and 6 100G QSFP28 ports, used for high-density server access or as a TOR switch.
| Parameter | Value |
|---|---|
| AC input voltage | 90v AC to 290v AC |
| ACL — max number of egress Car | 1K |
| ACL — max number of egress Counter | 1K |
| ACL — max number of ingress ACL | 18K |
| Air flow direction | From front to rear or from rear to front |
| Buffer | 32M |
| Cable — LSTM1STK | SFP+ Cable 5m |
| Cable — LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| Cable — LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| Cable — LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| Cable — LSWM1QSTK3 | 40G QSFP+ to 4x10G SFP+ Cable 1m |
| Cable — LSWM1QSTK4 | 40G QSFP+ to 4x10G SFP+ Cable 3m |
| Cable — LSWM1QSTK5 | 40G QSFP+ to 4x10G SFP+ Cable 5m |
| Cable — LSWM1STK | SFP+ Cable 0.65m |
| Cable — LSWM2STK | SFP+ Cable 1.2m |
| Cable — LSWM3STK | SFP+ Cable 3m |
| Cable — QSFP-100G-4SFP-25G-CAB-1M | 100G QSFP28 to 4x25G SFP28 1m Passive Cable |
| Cable — QSFP-100G-4SFP-25G-CAB-3M | 100G QSFP28 to 4x25G SFP28 3m Passive Cable |
| Cable — QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m AOC |
| Cable — QSFP-100G-D-AOC-20M | 100G QSFP28 to 100G QSFP28 20m AOC |
| Cable — QSFP-100G-D-AOC-7M | 100G QSFP28 to 100G QSFP28 7m AOC |
| Cable — QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| Cable — QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| Cable — QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| Cable — QSFP-40G-D-AOC-10M | 40G QSFP+ to 40G QSFP+10m AOC |
| Cable — QSFP-40G-D-AOC-20M | 40G QSFP+ to 40G QSFP+20m AOC |
| Cable — QSFP-40G-D-AOC-7M | 40G QSFP+ to 40G QSFP+7m AOC |
| Cable — SFP-XG-D-AOC-10M | SFP+ to SFP+10m AOC |
| Cable — SFP-XG-D-AOC-20M | SFP+ to SFP+20m AOC |
| Cable — SFP-XG-D-AOC-7M | SFP+ to SFP+7m AOC |
| Configuration and maintenance | Console telnet and SSH terminals |
| CPU | LS-6805-54HF: C2000,2.4 GHz@4 Cores; LS-6805-54HF-H2: C3000,2.2GHz@4Core |
| DC Input Voltage | –36v DC to –72v DC |
| Device virtualization | IRF2.0 |
| Dimensions H*W*D | 44× 440 × 400 mm; (1.74×17.32×15.74 in) |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386; GB/T 9254; YD/T 993 |
| Fan — LSPM1FANSA | Ethernet Switch Fan Module(Power to Port Airflow) |
| Fan — LSPM1FANSB | Ethernet Switch Fan Module(Port to Power Airflow) |
| Fan tray slot | 5 Hot-swappable fan, fan speed adjustable and wind invertible. (3+2 redundancy) |
| Flash/SDRAM | 4G/8G |
| Forwarding Capacity | 1001.7 Mpps |
| Forwarding table — ECMP group | max 4K |
| Forwarding table — ECMP member per group | 2-128 |
| Forwarding table — IPv4 multicast routing | 128K |
| Forwarding table — IPv6 multicast routing | 64K |
| Forwarding table — max ND table size for IPv6 | 136K max |
| Forwarding table — max number of ARP entries IPv4 | 272K max |
| Forwarding table — max number of MAC per switch | 288K max |
| Forwarding table — max number of unicast routes IPv4 | 324K max |
| Forwarding table — max number of unicast routes IPv6 | 162K max |
| IEEE Standard | 802.3x/802.3ad/802.3AH/802.1P/802.1Q/802.1X/802.1D/802.1w/802.1s/802.1AG; 802.1x/802.1Qbb/802.1az/802.1Qaz |
| Interface — IPv4 tunnel number | 2K |
| Interface — IPv6 tunnel number | 2K |
| Interface — Loopback interface number | 1K |
| Interface — SVI interface number | 2K |
| Interface — VSI interface number | 8K |
| Interface — VxLAN AC number | 16K |
| Interface — VxLAN tunnel number | 2K |
| Interface — VxLAN VSI number | 16K |
| IPv4 routing | Static routing and default routing |
| IPv6 routing | Static routing and default routing |
| Latency | < 800 ns (64 byte) |
| Lossless network | PFC and ECN |
| MAC Address | Dynamic learning and aging of mac address entries |
| Maximum power consumption | PSR250-12A/PSR250-12A1:; · Single AC input: 208 W; · Dual AC inputs: 213 W; PSR450-12A/PSR450-12A1:; · Single AC input: 208 W; · Dual AC inputs: 213 W; PSR450-12AHD:; · Single DC input: 202 W; · Dual DC inputs: 214 W; PSR450-12D:; · Single DC input: 207 W; · Dual DC inputs: 217 W |
| MPLS/VPLS | Support L3 MPLS VPN |
| MTBF(years) | 35.4 |
| Multicast | IGMP snooping |
| Network virtualization | BGP-EVPN |
| Operating humidity (noncondensing) | 5% RH to 95% RH, noncondensing |
| Operating Temperature | 0°C to 45°C (32°F to 113°F) |
| Out-of-band management port | One GE copper port and one GE fiber port |
| Performance — RIB | 500K |
| PID | LS-6805-54HF-H2 |
| PID — LS-6805-54HF-H2 | H3C S6805-54HF L3 Ethernet Switch with 48 SFP Plus Ports and 6 QSFP28 Ports |
| PID — LS-6805-54HT-H2 | H3C S6805-54HT L3 Ethernet Switch with 48 10G BASE-T Ports and 6 QSFP28 Ports |
| Power — PSR450-12A1 | 450W AC Power Supply Module |
| Power — PSR450-12AHD | 450W AC Power Supply Module,Support 240V/336V HVDC Input |
| Power — PSR450-12D | 450W DC Power Supply Module |
| Programmability | Openflow1.3 |
| QoS | Weighted Random Early Detection (WRED) and tail drop |
| Reliability | LACP |
| Safety | UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| SDN | H3C SeerEngine-DC |
| Security and management | Micro-Segmentation |
| Static table — static ARP | 1K |
| Static table — static IPv4 routing table | 2K |
| Static table — static multicast mac-address | 1K |
| Static table — static ND | 4K |
| Switching Capacity | 2.16 Tbps |
| Telemetry | gRPC |
| Traffic analysis | sFlow/NetStream |
| Transceiver — QSFP-100G-ER4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,40km,ER4L,WDM,LC) |
| Transceiver — QSFP-100G-LR4-WDM1300 | 100G QSFP28 Optical Transceiver Module(1310nm,10km,LR4,WDM,LC) |
| Transceiver — QSFP-100G-LR4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,2km,LR4L,CWDM4,LC) |
| Transceiver — QSFP-100G-PSM4-SM1310 | 100G QSFP28 Optical Transceiver Module (1310nm,500m,PSM4,MPO/APC) |
| Transceiver — QSFP-100G-SR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,100m OM4,SR4,MPO) |
| Transceiver — QSFP-100G-ZR4-WDM1300 | 100G QSFP28 Optical Transceiver Module (1300nm,80km,ZR4,WDM,LC) |
| Transceiver — QSFP-40G-BIDI-SR-MM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,100m,SR) |
| Transceiver — QSFP-40G-CSR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,300m,CSR4,Support 40G to 4*10G) |
| Transceiver — QSFP-40G-LR4-PSM1310 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,10km,MPO/APC,LR4,Parallel Single Mode) |
| Transceiver — QSFP-40G-LR4-WDM1300 | 40GBASE-LR4 QSFP+ Optical Transceiver Module |
| Transceiver — QSFP-40G-LR4L-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,2km,LR4L,LC) |
| Transceiver — QSFP-40G-SR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,100m,SR4,Support 40G to 4*10G) |
| Transceiver — SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| Transceiver — SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| Transceiver — SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| Transceiver — SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| Transceiver — SFP-GE-T | 1000BASE-T SFP |
| Transceiver — SFP-XG-LH40-SM1550 | SFP+ Module(1550nm,40km,LC) |
| Transceiver — SFP-XG-LH80-SM1550 | SFP+ Module(1550nm,80km,LC) |
| Transceiver — SFP-XG-LH80-SM1550-D | SFP+ Module(1550nm,80km,LC) |
| Transceiver — SFP-XG-LX-SM1310 | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-LX-SM1310-D | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-LX-SM1310-E | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-SX-MM850-A | SFP+ Module(850nm,300m,LC) |
| Typical Power Consumption | PSR250-12A/PSR250-12A1:; · Single AC input: 120 W; · Dual AC inputs: 127 W; PSR450-12A/PSR450-12A1:; · Single AC input: 120 W; · Dual AC inputs: 127 W PSR450-12D:; · Single DC input: 130 W; · Dual DC inputs: 135 W |
| VLAN | Port-based VLANs |
| VXLAN | L2 VxLAN gateway |
| Weight | ≤ 10 kg (22.04 lb) |
Points to check before using S6805 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| AC input voltage | 90v AC to 290v AC |
| DC Input Voltage | –36v DC to –72v DC |
| Maximum power consumption | PSR250-12A/PSR250-12A1:; · Single AC input: 208 W; · Dual AC inputs: 213 W; PSR450-12A/PSR450-12A1:; · Single AC input: 208 W; · Dual AC inputs: 213 W; PSR450-12AHD:; · Single DC input: 202 W; · Dual DC inputs: 214 W; PSR450-12D:; · Single DC input: 207 W; · Dual DC inputs: 217 W |
| Power — PSR450-12A1 | 450W AC Power Supply Module |
| Power — PSR450-12AHD | 450W AC Power Supply Module,Support 240V/336V HVDC Input |
| Power — PSR450-12D | 450W DC Power Supply Module |
| Typical Power Consumption | PSR250-12A/PSR250-12A1:; · Single AC input: 120 W; · Dual AC inputs: 127 W; PSR450-12A/PSR450-12A1:; · Single AC input: 120 W; · Dual AC inputs: 127 W PSR450-12D:; · Single DC input: 130 W; · Dual DC inputs: 135 W |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of S6805 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Safety": UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1.
Yes — recorded under "Fan — LSPM1FANSA": Ethernet Switch Fan Module(Power to Port Airflow).
Yes — recorded under "Flash/SDRAM": 4G/8G.
0°C to 45°C (32°F to 113°F) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Data center L3 switch with 48 10G SFP+ and 6 100G QSFP28 ports

H3C Series Data Center Switches

GbE L2+ Managed Switch

12 Port Gigabit Layer 2 Managed Industrial PoE++ Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S6805 |
| Manufacturer | H3C |
Campus Access Switches
Fully managed 48-port 1G PoE+ switch with 2 10G and 2 SFP+ ports · Ref. : GSM4352PB
Price on request
Campus Access Switches
Industrial Gigabit managed PoE switch with SFP ports · Ref. : DIS-300G-8PSW
Price on request
Campus Access Switches
Layer 2 PoE campus access switch, 5 ports
Price on request
Campus Access Switches
Multi-gigabit managed switch with 8x 2.5G ports and 10G SFP+ ports · Ref. : GWN7721
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details