S6825
48-port 25G SFP28 and 6-port 100G QSFP28 L3 data center switch

- Operating Temperature
- 0°C to 45°C (32°F to 113°F)
- Interface — IPv4 tunnel number
- 2K
- Interface — IPv6 tunnel number
- 2K
- Interface — Loopback interface number
- 1K
48-port 25G SFP28 and 6-port 100G QSFP28 L3 data center switch
The H3C S6825-54HF is a high-density L3 switch for data centers and cloud computing networks, with 48 SFP28 25G ports and 6 QSFP28 100G ports for 25GE access and aggregation.
Overview. The H3C S6825-54HF (chassis LS-6825-54HF-H1) is an L3 Ethernet data center switch from H3C. It provides 48 SFP28 25G ports and 6 QSFP28 100G ports, the 100G ports being 100G/40G autosensing, plus two out-of-band management ports, one GE copper and one GE fiber. It can operate as a TOR access switch on an overlay or integrated network.
Main characteristics. C3000 CPU at 2.2 GHz, 4 cores, forwarding capacity of 1001.7 Mpps, latency below 1 μs, 32M byte buffer, 4GB Flash/SDRAM on the LS-6825-54HF and 4GB Flash with 8GB SDRAM on the LS-6825-54HF-H1. Forwarding tables reach 288K MAC addresses, 272K IPv4 ARP entries and 324K IPv4 unicast routes. Device virtualization uses IRF2.0.
Routing and multicast. IPv4 static and default routing, RIP v1/2, OSPF, IS-IS, BGP, routing policy, VRRP and PBR; IPv6 routing with RIPng, OSPFv3, IPv6 IS-IS, BGP4+ and VRRP; multicast with IGMP and MLD snooping, PIM, MSDP and Multicast VPN. MPLS/VPLS functions include L3 MPLS VPN, L2 VLL (Martini, Kompella), LDP and MPLS OAM.
Data center and lossless network. VXLAN and BGP-EVPN support for network virtualization, FCoE, PFC, ECN and DCBX, and RDMA and RoCE for FC storage and low-latency applications. Interfaces include VXLAN tunnels, VSIs and SVIs.
Configuration and operations. Console, Telnet and SSH access, SNMPv1/v2/v3, ZTP, system log, file transfer via FTP and TFTP, BootRom update, NQA, ping, tracert, NTP, PTP (IEEE 1588v2) and GIR (graceful insertion and removal).
Power, cooling and environment. AC input of 90 to 290 V AC or DC input of –36 to –72 V DC, front-to-rear or rear-to-front airflow, five hot-swappable fans, maximum heat dissipation of 761 BTU/hour for single AC, 778 for dual AC, 764 for single DC and 775 for dual DC. Operating temperature 0 °C to 45 °C, humidity 5% to 95% non-condensing. Dimensions 44 × 440 × 400 mm, MTBF 35.4 years.
Compliance. Emissions comply with FCC Part 15 Subpart B Class A, ICES-003, VCCI, CISPR 32, EN 55032, AS/NZS CISPR32, EN 55024, EN 61000-3-2 and EN 61000-3-3.
Cables and accessories. SFP+, SFP28 and QSFP+ cables, passive copper or active optical, from 0.65 m to 20 m depending on type, and fan modules LSPM1FANSA (power to port airflow) and LSPM1FANSB (port to power airflow).
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S6825, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC input voltage | 90v AC to 290v AC |
| ACL — max number of egress Car | 1K |
| ACL — max number of egress Counter | 1K |
| ACL — max number of ingress ACL | 18K |
| Air flow direction | Front to rear or rear to front |
| Buffer(byte) | 32M |
| Cable — LSTM1STK | SFP+ Cable 5m |
| Cable — LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| Cable — LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| Cable — LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| Cable — LSWM1STK | SFP+ Cable 0.65m |
| Cable — LSWM2STK | SFP+ Cable 1.2m |
| Cable — LSWM3STK | SFP+ Cable 3m |
| Cable — QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m AOC |
| Cable — QSFP-100G-D-AOC-7M | 100G QSFP28 to 100G QSFP28 7m AOC |
| Cable — QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| Cable — QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| Cable — QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| Cable — QSFP-40G-D-AOC-10M | 40G QSFP+ to 40G QSFP+10m AOC |
| Cable — QSFP-40G-D-AOC-20M | 40G QSFP+ to 40G QSFP+20m AOC |
| Cable — QSFP-40G-D-AOC-7M | 40G QSFP+ to 40G QSFP+7m AOC |
| Cable — SFP-25G-D-AOC-10M | 25G SFP28 to 25G SFP28 10m Active Optical Cable |
| Cable — SFP-25G-D-AOC-20M | 25G SFP28 to 25G SFP28 20m Active Optical Cable |
| Cable — SFP-25G-D-AOC-3M | 25G SFP28 to 25G SFP28 3m Active Optical Cable |
| Cable — SFP-25G-D-AOC-5M | 25G SFP28 to 25G SFP28 5m Active Optical Cable |
| Cable — SFP-25G-D-AOC-7M | 25G SFP28 to 25G SFP28 7m Active Optical Cable |
| Cable — SFP-25G-D-CAB-1M | 25G SFP28 to 25G SFP28 1m Passive Cable |
| Cable — SFP-25G-D-CAB-3M | 25G SFP28 to 25G SFP28 3m Passive Cable |
| Cable — SFP-25G-D-CAB-5M | 25G SFP28 to 25G SFP28 5m Passive Cable |
| Cable — SFP-XG-D-AOC-10M | SFP+ to SFP+10m AOC |
| Cable — SFP-XG-D-AOC-20M | SFP+ to SFP+20m AOC |
| Cable — SFP-XG-D-AOC-7M | SFP+ to SFP+7m AOC |
| Chassis — LS-6825-54HF-H1 | H3C S6825-54HF L3 Ethernet Switch with 48*25G SFP28 Ports and 6*100G QSFP28 Ports |
| Configuration and maintenance | Console telnet and SSH terminals; SNMPv1/v2/v3; ZTP; System log; File upload and download via FTP/TFTP; BootRom update and remote update; NQA; ping,tracert; VxLAN ping and VxLAN tracert; NTP; PTP(1588v2); GIR Graceful Insertion and Removal |
| CPU | C3000, 2.2GHz@4Core |
| DC Input Voltage | –36v DC to –72v DC |
| Device virtualization | IRF2.0 |
| Dimensions H*W*D | 44 × 440 × 400 mm |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386; GB/T 9254; YD/T 993 |
| Fan — LSPM1FANSA | H3C Fan Module with Power to Port Airflow |
| Fan — LSPM1FANSB | H3C Fan Module with Port to Power Airflow |
| Fan tray slot | 5 Hot-swappable fans |
| FCoE | FCOE |
| Flash/SDRAM | LS-6825-54HF : 4GB/4G; LS-6825-54HF-H1:4GB/8G |
| Forwarding Capacity | 1001.7 Mpps |
| Forwarding table — ECMP group | max 4K |
| Forwarding table — ECMP member per group | 2-128 |
| Forwarding table — IPv4 multicast routing | 128K |
| Forwarding table — IPv6 multicast routing | 64K |
| Forwarding table — max ND table size for IPv6 | 136K max |
| Forwarding table — max number of ARP entries IPv4 | 272K max |
| Forwarding table — max number of MAC per switch | 288K max |
| Forwarding table — max number of unicast routes IPv4 | 324K max |
| Forwarding table — max number of unicast routes IPv6 | 162K max |
| IEEE Standard | 802.3x/802.3ad/802.3AH/802.1P/802.1Q/802.1X/802.1D/802.1w/802.1s/802.1AG; 802.1x/802.1Qbb/802.1az/802.1Qaz |
| Interface — IPv4 tunnel number | 2K |
| Interface — IPv6 tunnel number | 2K |
| Interface — Loopback interface number | 1K |
| Interface — SVI interface number | 2K |
| Interface — VSI interface number | 8K |
| Interface — VxLAN AC number | 16K |
| Interface — VxLAN tunnel number | 2K |
| Interface — VxLAN VSI number | 16K |
| IPv4 routing | Static routing and default routing; RIP(Routing Information Protocol) v1/2; OSPF (Open Shortest Path First) v1/v2; ISIS(Intermediate System to Intermediate system); BGP (Border Gateway Protocol); Routing policy; VRRP; PBR |
| IPv6 routing | StaticroutinganddefaultroutingRIPng; OSPFv3; IPv6 ISIS; BGP4+; Routing policy; VRRP; PBR |
| Latency | <1μs |
| Lossless network | PFC and ECN; DCBX; RDMA and ROCE; PFC deadlock watchdog; ECN overlay; ROCE stream analysis |
| MAC Address | Dynamic learning and aging of mac address entries; Dynamic,static and blackhole entries; Mac address limiting on ports |
| Maximum heat consumption; (BTU/hour) | Single AC: 761; Dual AC: 778; Single DC: 764; Dual DC: 775 |
| MPLS/VPLS | Support L3 MPLS VPN; Support L2 VPN: VLL (Martini, Kompella); Support VPLS, VLL; Support hierarchical VPLS and QinQ+VPLS access; Support P/PE function; Support LDP protocol; Support MCE; Support MPLS OAM |
| MTBF(years) | 35.4 |
| Multicast | IGMP snooping; MLD snooping; IPv4 and IPv6 multicast VLAN; IPv4 and IPv6 PIM snooping; IGMP and MLD; PIM and IPv6 PIM; MSDP; Multicast VPN |
| Network virtualization | BGP-EVPN |
| Operating Humidity | 5% to 95%, noncondensing |
| Operating Temperature | 0°C to 45°C (32°F to 113°F) |
| Out-of-band management port | One GE copper port and one GE fiber port |
| Performance — RIB | 500K |
| Power — PSR450-12A | 450W AC Power Supply Module (Air Inlets in Panel) |
| Power — PSR450-12A1 | 450W AC Power Supply Module (Air Outlets in Panel) |
| Power — PSR450-12AHD | 450W HVDC Power Supply Module (AC/336V HVDC Input Supported, Air Outlets in Panel) |
| Power — PSR450-12D | 450W DC Power Supply Module (Air Outlets in Panel) |
| Programmability | Openflow1.3; Netconf; Ansible; Python//TCL/Restful API to realize DevOps automated operation and maintenance |
| Reliability | LACP; STP/RSTP/MSTP protocol, RPVST+/PVST+/ PVST compatible; STP Root Guard and BPDU Guard; RRPP and ERPS; Ethernet OAM |
| Safety | UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| SDN | H3C SeerEngine-DC |
| Security and management | Micro-Segmentation; Hierarchical management and password protection of users; Authentication methods, including AAA,RADIUS and HWTACACS; Support DDos, ARP attack and ICMP attack function; IP-MAC-port binding and IP Source Guard; SSH 2.0; HTTPS; SSL; PKI; Boot ROM access control (password recovery); RMON; systemidentificationLEDandinterfaceidentificationLED |
| Static Power Consumption | Single AC: 78 W; Dual AC: 87 W; Single DC: 79 W; Dual DC: 88 W |
| Static table — static ARP | 1K |
| Static table — static IPv4 routing table | 2K |
| Static table — static multicast mac-address | 1K |
| Static table — static ND | 4K |
| Switching Capacity | 3.6 Tbps |
| Telemetry | gRPC; ERSPAN; Mirror on drop; Telemetry Stream; INT; iNQA; Packet trace, Packet capture |
| Traffic analysis | Sflow |
| Transceiver — QSFP-100G-LR4-WDM1300 | 100G QSFP28 Optical Transceiver Module(1310nm,10km,LR4,WDM,LC) |
| Transceiver — QSFP-100G-LR4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,2km,LR4L,CWDM4,LC) |
| Transceiver — QSFP-100G-PSM4-SM1310 | 100G QSFP28 Optical Transceiver Module (1310nm,500m,PSM4,MPO/APC) |
| Transceiver — QSFP-100G-SR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,100m OM4,SR4,MPO) |
| Transceiver — QSFP-40G-BIDI-SR-MM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,100m,SR) |
| Transceiver — QSFP-40G-CSR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,300m,CSR4,Support 40G to 4*10G) |
| Transceiver — QSFP-40G-ER4-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,40km,ER4,LC) |
| Transceiver — QSFP-40G-LR4-PSM1310 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,10km,MPO/APC,LR4,Parallel Single Mode) |
| Transceiver — QSFP-40G-LR4-WDM1300 | 40GBASE-LR4 QSFP+ Optical Transceiver Module |
| Transceiver — QSFP-40G-LR4L-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,2km,LR4L,LC) |
| Transceiver — QSFP-40G-SR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,100m,SR4,Support 40G to 4*10G) |
| Transceiver — SFP-10GE-T | SFP+ 10GE Copper Interface Transceiver Module(Cat6a/Cat7,30m,RJ45) (Auto-MDIX) |
| Transceiver — SFP-25G-SR-MM850 | 25G SFP28 Optical Transceiver Module (850nm,100m,SR,MM,LC) |
| Transceiver — SFP-FE-LH40-SM1310 | 100BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-FE-LX-SM1310-A | 100BASE-LX SFP Transceiver, Single Mode (1310nm, 15km, LC) |
| Transceiver — SFP-FE-SX-MM1310-A | 100BASE-FX SFP Transceiver, Multi-Mode (1310nm, 2km, LC) |
| Transceiver — SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| Transceiver — SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| Transceiver — SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| Transceiver — SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| Transceiver — SFP-GE-T | SFP GE Copper Interface Transceiver Module (100m, RJ45) |
| Transceiver — SFP-XG-LX-SM1310 | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-SX-MM850-A | SFP+ Module(850nm,300m,LC) |
| Typical Power Consumption | Single AC: 223 W; Dual AC: 228 W; Single DC: 224 W; Dual DC: 227 W |
| VLAN | Port-based VLANs; Mac-based VLAN,Subnet-based VLAN and Protocol VLAN; VLAN mapping; QinQ; MVRP(Multiple VLAN Registration Protocol); Super VLAN; PVLAN |
| VXLAN | L2 VxLAN gateway; L3 VxLAN gateway; Distributed VxLAN gateway; Centralized VxLAN gateway; EVPN VxLAN; manual configured VxLAN; IPv4 VxLAN tunnel; IPv6 VxLAN tunnel; QinQ VxLAN access |
| Weight | ≤ 10 kg (22.05 lb) |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S6825. For a missing document or a specific revision, our experts send it to you.
The H3C S6825-54HF is a high-density L3 switch for data centers and cloud computing networks, with 48 SFP28 25G ports and 6 QSFP28 100G ports for 25GE access and aggregation.
| Parameter | Value |
|---|---|
| AC input voltage | 90v AC to 290v AC |
| ACL — max number of egress Car | 1K |
| ACL — max number of egress Counter | 1K |
| ACL — max number of ingress ACL | 18K |
| Air flow direction | Front to rear or rear to front |
| Buffer(byte) | 32M |
| Cable — LSTM1STK | SFP+ Cable 5m |
| Cable — LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| Cable — LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| Cable — LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| Cable — LSWM1STK | SFP+ Cable 0.65m |
| Cable — LSWM2STK | SFP+ Cable 1.2m |
| Cable — LSWM3STK | SFP+ Cable 3m |
| Cable — QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m AOC |
| Cable — QSFP-100G-D-AOC-7M | 100G QSFP28 to 100G QSFP28 7m AOC |
| Cable — QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| Cable — QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| Cable — QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| Cable — QSFP-40G-D-AOC-10M | 40G QSFP+ to 40G QSFP+10m AOC |
| Cable — QSFP-40G-D-AOC-20M | 40G QSFP+ to 40G QSFP+20m AOC |
| Cable — QSFP-40G-D-AOC-7M | 40G QSFP+ to 40G QSFP+7m AOC |
| Cable — SFP-25G-D-AOC-10M | 25G SFP28 to 25G SFP28 10m Active Optical Cable |
| Cable — SFP-25G-D-AOC-20M | 25G SFP28 to 25G SFP28 20m Active Optical Cable |
| Cable — SFP-25G-D-AOC-3M | 25G SFP28 to 25G SFP28 3m Active Optical Cable |
| Cable — SFP-25G-D-AOC-5M | 25G SFP28 to 25G SFP28 5m Active Optical Cable |
| Cable — SFP-25G-D-AOC-7M | 25G SFP28 to 25G SFP28 7m Active Optical Cable |
| Cable — SFP-25G-D-CAB-1M | 25G SFP28 to 25G SFP28 1m Passive Cable |
| Cable — SFP-25G-D-CAB-3M | 25G SFP28 to 25G SFP28 3m Passive Cable |
| Cable — SFP-25G-D-CAB-5M | 25G SFP28 to 25G SFP28 5m Passive Cable |
| Cable — SFP-XG-D-AOC-10M | SFP+ to SFP+10m AOC |
| Cable — SFP-XG-D-AOC-20M | SFP+ to SFP+20m AOC |
| Cable — SFP-XG-D-AOC-7M | SFP+ to SFP+7m AOC |
| Chassis — LS-6825-54HF-H1 | H3C S6825-54HF L3 Ethernet Switch with 48*25G SFP28 Ports and 6*100G QSFP28 Ports |
| Configuration and maintenance | Console telnet and SSH terminals; SNMPv1/v2/v3; ZTP; System log; File upload and download via FTP/TFTP; BootRom update and remote update; NQA; ping,tracert; VxLAN ping and VxLAN tracert; NTP; PTP(1588v2); GIR Graceful Insertion and Removal |
| CPU | C3000, 2.2GHz@4Core |
| DC Input Voltage | –36v DC to –72v DC |
| Device virtualization | IRF2.0 |
| Dimensions H*W*D | 44 × 440 × 400 mm |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386; GB/T 9254; YD/T 993 |
| Fan — LSPM1FANSA | H3C Fan Module with Power to Port Airflow |
| Fan — LSPM1FANSB | H3C Fan Module with Port to Power Airflow |
| Fan tray slot | 5 Hot-swappable fans |
| FCoE | FCOE |
| Flash/SDRAM | LS-6825-54HF : 4GB/4G; LS-6825-54HF-H1:4GB/8G |
| Forwarding Capacity | 1001.7 Mpps |
| Forwarding table — ECMP group | max 4K |
| Forwarding table — ECMP member per group | 2-128 |
| Forwarding table — IPv4 multicast routing | 128K |
| Forwarding table — IPv6 multicast routing | 64K |
| Forwarding table — max ND table size for IPv6 | 136K max |
| Forwarding table — max number of ARP entries IPv4 | 272K max |
| Forwarding table — max number of MAC per switch | 288K max |
| Forwarding table — max number of unicast routes IPv4 | 324K max |
| Forwarding table — max number of unicast routes IPv6 | 162K max |
| IEEE Standard | 802.3x/802.3ad/802.3AH/802.1P/802.1Q/802.1X/802.1D/802.1w/802.1s/802.1AG; 802.1x/802.1Qbb/802.1az/802.1Qaz |
| Interface — IPv4 tunnel number | 2K |
| Interface — IPv6 tunnel number | 2K |
| Interface — Loopback interface number | 1K |
| Interface — SVI interface number | 2K |
| Interface — VSI interface number | 8K |
| Interface — VxLAN AC number | 16K |
| Interface — VxLAN tunnel number | 2K |
| Interface — VxLAN VSI number | 16K |
| IPv4 routing | Static routing and default routing; RIP(Routing Information Protocol) v1/2; OSPF (Open Shortest Path First) v1/v2; ISIS(Intermediate System to Intermediate system); BGP (Border Gateway Protocol); Routing policy; VRRP; PBR |
| IPv6 routing | StaticroutinganddefaultroutingRIPng; OSPFv3; IPv6 ISIS; BGP4+; Routing policy; VRRP; PBR |
| Latency | <1μs |
| Lossless network | PFC and ECN; DCBX; RDMA and ROCE; PFC deadlock watchdog; ECN overlay; ROCE stream analysis |
| MAC Address | Dynamic learning and aging of mac address entries; Dynamic,static and blackhole entries; Mac address limiting on ports |
| Maximum heat consumption; (BTU/hour) | Single AC: 761; Dual AC: 778; Single DC: 764; Dual DC: 775 |
| MPLS/VPLS | Support L3 MPLS VPN; Support L2 VPN: VLL (Martini, Kompella); Support VPLS, VLL; Support hierarchical VPLS and QinQ+VPLS access; Support P/PE function; Support LDP protocol; Support MCE; Support MPLS OAM |
| MTBF(years) | 35.4 |
| Multicast | IGMP snooping; MLD snooping; IPv4 and IPv6 multicast VLAN; IPv4 and IPv6 PIM snooping; IGMP and MLD; PIM and IPv6 PIM; MSDP; Multicast VPN |
| Network virtualization | BGP-EVPN |
| Operating Humidity | 5% to 95%, noncondensing |
| Operating Temperature | 0°C to 45°C (32°F to 113°F) |
| Out-of-band management port | One GE copper port and one GE fiber port |
| Performance — RIB | 500K |
| Power — PSR450-12A | 450W AC Power Supply Module (Air Inlets in Panel) |
| Power — PSR450-12A1 | 450W AC Power Supply Module (Air Outlets in Panel) |
| Power — PSR450-12AHD | 450W HVDC Power Supply Module (AC/336V HVDC Input Supported, Air Outlets in Panel) |
| Power — PSR450-12D | 450W DC Power Supply Module (Air Outlets in Panel) |
| Programmability | Openflow1.3; Netconf; Ansible; Python//TCL/Restful API to realize DevOps automated operation and maintenance |
| Reliability | LACP; STP/RSTP/MSTP protocol, RPVST+/PVST+/ PVST compatible; STP Root Guard and BPDU Guard; RRPP and ERPS; Ethernet OAM |
| Safety | UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| SDN | H3C SeerEngine-DC |
| Security and management | Micro-Segmentation; Hierarchical management and password protection of users; Authentication methods, including AAA,RADIUS and HWTACACS; Support DDos, ARP attack and ICMP attack function; IP-MAC-port binding and IP Source Guard; SSH 2.0; HTTPS; SSL; PKI; Boot ROM access control (password recovery); RMON; systemidentificationLEDandinterfaceidentificationLED |
| Static Power Consumption | Single AC: 78 W; Dual AC: 87 W; Single DC: 79 W; Dual DC: 88 W |
| Static table — static ARP | 1K |
| Static table — static IPv4 routing table | 2K |
| Static table — static multicast mac-address | 1K |
| Static table — static ND | 4K |
| Switching Capacity | 3.6 Tbps |
| Telemetry | gRPC; ERSPAN; Mirror on drop; Telemetry Stream; INT; iNQA; Packet trace, Packet capture |
| Traffic analysis | Sflow |
| Transceiver — QSFP-100G-LR4-WDM1300 | 100G QSFP28 Optical Transceiver Module(1310nm,10km,LR4,WDM,LC) |
| Transceiver — QSFP-100G-LR4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,2km,LR4L,CWDM4,LC) |
| Transceiver — QSFP-100G-PSM4-SM1310 | 100G QSFP28 Optical Transceiver Module (1310nm,500m,PSM4,MPO/APC) |
| Transceiver — QSFP-100G-SR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,100m OM4,SR4,MPO) |
| Transceiver — QSFP-40G-BIDI-SR-MM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,100m,SR) |
| Transceiver — QSFP-40G-CSR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,300m,CSR4,Support 40G to 4*10G) |
| Transceiver — QSFP-40G-ER4-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,40km,ER4,LC) |
| Transceiver — QSFP-40G-LR4-PSM1310 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,10km,MPO/APC,LR4,Parallel Single Mode) |
| Transceiver — QSFP-40G-LR4-WDM1300 | 40GBASE-LR4 QSFP+ Optical Transceiver Module |
| Transceiver — QSFP-40G-LR4L-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,2km,LR4L,LC) |
| Transceiver — QSFP-40G-SR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,100m,SR4,Support 40G to 4*10G) |
| Transceiver — SFP-10GE-T | SFP+ 10GE Copper Interface Transceiver Module(Cat6a/Cat7,30m,RJ45) (Auto-MDIX) |
| Transceiver — SFP-25G-SR-MM850 | 25G SFP28 Optical Transceiver Module (850nm,100m,SR,MM,LC) |
| Transceiver — SFP-FE-LH40-SM1310 | 100BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-FE-LX-SM1310-A | 100BASE-LX SFP Transceiver, Single Mode (1310nm, 15km, LC) |
| Transceiver — SFP-FE-SX-MM1310-A | 100BASE-FX SFP Transceiver, Multi-Mode (1310nm, 2km, LC) |
| Transceiver — SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| Transceiver — SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| Transceiver — SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| Transceiver — SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| Transceiver — SFP-GE-T | SFP GE Copper Interface Transceiver Module (100m, RJ45) |
| Transceiver — SFP-XG-LX-SM1310 | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-SX-MM850-A | SFP+ Module(850nm,300m,LC) |
| Typical Power Consumption | Single AC: 223 W; Dual AC: 228 W; Single DC: 224 W; Dual DC: 227 W |
| VLAN | Port-based VLANs; Mac-based VLAN,Subnet-based VLAN and Protocol VLAN; VLAN mapping; QinQ; MVRP(Multiple VLAN Registration Protocol); Super VLAN; PVLAN |
| VXLAN | L2 VxLAN gateway; L3 VxLAN gateway; Distributed VxLAN gateway; Centralized VxLAN gateway; EVPN VxLAN; manual configured VxLAN; IPv4 VxLAN tunnel; IPv6 VxLAN tunnel; QinQ VxLAN access |
| Weight | ≤ 10 kg (22.05 lb) |
Points to check before using S6825 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| AC input voltage | 90v AC to 290v AC |
| DC Input Voltage | –36v DC to –72v DC |
| Maximum heat consumption; (BTU/hour) | Single AC: 761; Dual AC: 778; Single DC: 764; Dual DC: 775 |
| Power — PSR450-12A | 450W AC Power Supply Module (Air Inlets in Panel) |
| Power — PSR450-12A1 | 450W AC Power Supply Module (Air Outlets in Panel) |
| Power — PSR450-12AHD | 450W HVDC Power Supply Module (AC/336V HVDC Input Supported, Air Outlets in Panel) |
| Power — PSR450-12D | 450W DC Power Supply Module (Air Outlets in Panel) |
| Static Power Consumption | Single AC: 78 W; Dual AC: 87 W; Single DC: 79 W; Dual DC: 88 W |
| Typical Power Consumption | Single AC: 223 W; Dual AC: 228 W; Single DC: 224 W; Dual DC: 227 W |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of S6825 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Safety": UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1.
Yes — recorded under "Chassis — LS-6825-54HF-H1": H3C S6825-54HF L3 Ethernet Switch with 48*25G SFP28 Ports and 6*100G QSFP28 Ports.
Yes — recorded under "Flash/SDRAM": LS-6825-54HF : 4GB/4G; LS-6825-54HF-H1:4GB/8G.
0°C to 45°C (32°F to 113°F) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
48-port 25G SFP28 and 6-port 100G QSFP28 L3 data center switch

H3C Series Data Center Switches

GbE L2+ Managed Switch

12 Port Gigabit Layer 2 Managed Industrial PoE++ Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S6825 |
| Manufacturer | H3C |
Campus Access Switches
Fully managed 48-port 1G PoE+ switch with 2 10G and 2 SFP+ ports · Ref. : GSM4352PB
Price on request
Campus Access Switches
Industrial Gigabit managed PoE switch with SFP ports · Ref. : DIS-300G-8PSW
Price on request
Campus Access Switches
Layer 2 PoE campus access switch, 5 ports
Price on request
Campus Access Switches
Multi-gigabit managed switch with 8x 2.5G ports and 10G SFP+ ports · Ref. : GWN7721
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details