ZW20 – Outdoor High-Voltage AC Vacuum Circuit Breaker 12 kV

Outdoor High-Voltage AC Vacuum Circuit Breaker 12 kV

Miniature Circuit Breakers

  • 630 A
  • 10000 cycles
  • 50, 63 kA
  • 20, 25 kA
Manufacturer part number
ZW20
Manufacturer
Hexing
Rated Current
630 A

The Hexing ZW20 is a 12 kV outdoor three-phase 50 Hz vacuum circuit breaker with manual or motorized operation. It breaks and closes load, overload and short-circuit currents in distribution networks.

Product overview

Overview. The Hexing ZW20 outdoor vacuum circuit breaker is a 12 kV, three-phase 50 Hz outdoor power distribution switchgear designed to break and close load currents, overload currents and short-circuit currents. It is intended for substations and industrial distribution systems, especially rural power grids and locations requiring frequent operations.

Main characteristics. Rated current of 630 A, rated voltage of 12 kV and rated frequency of 50 Hz. Rated short-circuit breaking current of 20 or 25 kA, rated short-circuit making current (peak) of 50 or 63 kA, rated peak withstand current of 50 or 63 kA and rated short-time withstand current of 20 or 25 kA for 4 s. Mechanical life of 10,000 cycles and 10,000 rated current breaking cycles. Main circuit resistance per phase of 140 μΩ or less and three-phase opening/closing non-simultaneity of 2 ms or less.

Switching times and speeds. Closing time of 20 to 60 ms and opening time of 20 to 45 ms. Average closing speed of 0.6 ± 0.2 m/s and average opening speed of 1.1 ± 0.2 m/s.

Power supply and operation. Manual or motorized operation. Charging motor supply voltage and opening and closing operating voltages of AC 220 V. Rated power of the charging motor of 40 W or less.

Insulation and dielectric performance. Lightning impulse withstand voltage of 85 kV (peak) across the open contact and 75 kV (peak) phase-to-phase and phase-to-ground. External live air insulation distance of 240 ± 2 mm and external phase-to-phase center distance of 275 ± 1 mm.

Safety. Explosion-proof device installed on the top of the enclosure. Even in the event of an internal fault, no high-temperature gases or debris leak out.

Installation. Pole-hanging or base-mounted installation options.

See all specifications

Highlights

  • Average Closing Speed — m/s: 0.6 ± 0.2
  • Average Opening Speed — m/s: 1.1 ± 0.2
  • Charging Motor Voltage: AC220
  • Closing Operating Voltage: AC220
  • Closing Time — ms: 20 ~ 60
  • External Live Air Insulation Distance — mm: 240 ± 2

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.