ZW32 – 12 kV outdoor high-voltage AC vacuum circuit breaker 630 A

12 kV outdoor high-voltage AC vacuum circuit breaker 630 A

Miniature Circuit Breakers

  • A
  • kA
  • kV
  • Hz
Manufacturer part number
ZW32
Manufacturer
Hexing
Rated Current — 630
A

The Hexing ZW32 outdoor high-voltage AC vacuum circuit breaker switches load, overload and short-circuit currents on 12 kV three-phase 50 Hz networks. It is intended for substations and rural distribution grids.

Product overview

Overview. The Hexing ZW32 outdoor high-voltage AC vacuum circuit breaker is a three-phase 50 Hz distribution device rated 12 kV and 630 A. It is pole-mounted and used to make and break load, overload and short-circuit currents in power systems.

Main characteristics. Current interruption takes place by vacuum arc extinction, which ensures safety and reliable operation. The fully sealed enclosure requires no maintenance. The rated short-circuit breaking current is 20/25 kA (RMS) and the rated short-circuit making current 50/63 kA (peak). The rated peak withstand current is 50/63 kA and the rated short-time withstand current 20/25 kA for 4 s (RMS). The breaker withstands 30 short-circuit breaking operations and has a mechanical life of 10,000 cycles. The conductive circuit resistance is at most 70 μΩ per phase.

Operation and mechanical performance. The spring-operated or permanent magnet mechanism allows electric or manual operation. The charging motor power is 40 W. The closing speed is 0.75±0.2 m/s and the opening speed 1.25±0.2 m/s. The closing time is at most 60 ms, the opening time at most 45 ms, and the three-phase non-simultaneity at most 2 ms. The phase-to-phase centre distance is 340±2 mm.

Dielectric withstand. The power frequency withstand voltage (1 min, RMS) is 42 kV phase-to-phase and 48 kV phase-to-ground or open contact. The lightning impulse withstand voltage (peak) is 75/85 kV.

Typical uses. This breaker suits distribution substations, rural grids and industrial and mining installations where switching operations are frequent.

See all specifications

Highlights

  • Closing Speed — 0.75±0.2: m/s
  • Closing Time — ≤60: ms
  • Conductive Circuit Resistance per Phase — ≤70: μΩ
  • Lightning Impulse Withstand Voltage (Peak) — 75/85: kV
  • Mechanical Life — 10000: Cycles
  • Number of Short-Circuit Breaking Operations — 30: Cycles

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.