ZW32
12 kV outdoor high-voltage AC vacuum circuit breaker 630 A

- Rated Current — 630
- A
- Rated Peak Withstand Current (Peak) — 50/63
- kA
- Rated Short-Circuit Breaking Current (RMS) — 20/25
- kA
- Rated Short-Circuit Making Current (Peak) — 50/63
- kA
12 kV outdoor high-voltage AC vacuum circuit breaker 630 A
The Hexing ZW32 outdoor high-voltage AC vacuum circuit breaker switches load, overload and short-circuit currents on 12 kV three-phase 50 Hz networks. It is intended for substations and rural distribution grids.
Overview. The Hexing ZW32 outdoor high-voltage AC vacuum circuit breaker is a three-phase 50 Hz distribution device rated 12 kV and 630 A. It is pole-mounted and used to make and break load, overload and short-circuit currents in power systems.
Main characteristics. Current interruption takes place by vacuum arc extinction, which ensures safety and reliable operation. The fully sealed enclosure requires no maintenance. The rated short-circuit breaking current is 20/25 kA (RMS) and the rated short-circuit making current 50/63 kA (peak). The rated peak withstand current is 50/63 kA and the rated short-time withstand current 20/25 kA for 4 s (RMS). The breaker withstands 30 short-circuit breaking operations and has a mechanical life of 10,000 cycles. The conductive circuit resistance is at most 70 μΩ per phase.
Operation and mechanical performance. The spring-operated or permanent magnet mechanism allows electric or manual operation. The charging motor power is 40 W. The closing speed is 0.75±0.2 m/s and the opening speed 1.25±0.2 m/s. The closing time is at most 60 ms, the opening time at most 45 ms, and the three-phase non-simultaneity at most 2 ms. The phase-to-phase centre distance is 340±2 mm.
Dielectric withstand. The power frequency withstand voltage (1 min, RMS) is 42 kV phase-to-phase and 48 kV phase-to-ground or open contact. The lightning impulse withstand voltage (peak) is 75/85 kV.
Typical uses. This breaker suits distribution substations, rural grids and industrial and mining installations where switching operations are frequent.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ZW32, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Closing Speed — 0.75±0.2 | m/s |
| Closing Time — ≤60 | ms |
| Conductive Circuit Resistance per Phase — ≤70 | μΩ |
| Lightning Impulse Withstand Voltage (Peak) — 75/85 | kV |
| Mechanical Life — 10000 | Cycles |
| Number of Short-Circuit Breaking Operations — 30 | Cycles |
| Opening Speed — 1.25±0.2 | m/s |
| Opening Time — ≤45 | ms |
| Phase-to-Phase Center Distance — 340±2 | mm |
| Power Frequency Withstand Voltage (1min): Phase-to-Phase, Phase-to-Ground/Open Contact (RMS) — 42/48 | kV |
| Rated Current — 630 | A |
| Rated Frequency — 50 | Hz |
| Rated Peak Withstand Current (Peak) — 50/63 | kA |
| Rated Power of Charging Motor — 40 | W |
| Rated Short-Circuit Breaking Current (RMS) — 20/25 | kA |
| Rated Short-Circuit Making Current (Peak) — 50/63 | kA |
| Rated Short-Time Withstand Current (4s) (RMS) — 20/25 | kA |
| Rated Voltage — 12 | kV |
| Three-Phase Non-Simultaneity — ≤2 | ms |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for ZW32. For a missing document or a specific revision, our experts send it to you.
The Hexing ZW32 outdoor high-voltage AC vacuum circuit breaker switches load, overload and short-circuit currents on 12 kV three-phase 50 Hz networks. It is intended for substations and rural distribution grids.
| Parameter | Value |
|---|---|
| Closing Speed — 0.75±0.2 | m/s |
| Closing Time — ≤60 | ms |
| Conductive Circuit Resistance per Phase — ≤70 | μΩ |
| Lightning Impulse Withstand Voltage (Peak) — 75/85 | kV |
| Mechanical Life — 10000 | Cycles |
| Number of Short-Circuit Breaking Operations — 30 | Cycles |
| Opening Speed — 1.25±0.2 | m/s |
| Opening Time — ≤45 | ms |
| Phase-to-Phase Center Distance — 340±2 | mm |
| Power Frequency Withstand Voltage (1min): Phase-to-Phase, Phase-to-Ground/Open Contact (RMS) — 42/48 | kV |
| Rated Current — 630 | A |
| Rated Frequency — 50 | Hz |
| Rated Peak Withstand Current (Peak) — 50/63 | kA |
| Rated Power of Charging Motor — 40 | W |
| Rated Short-Circuit Breaking Current (RMS) — 20/25 | kA |
| Rated Short-Circuit Making Current (Peak) — 50/63 | kA |
| Rated Short-Time Withstand Current (4s) (RMS) — 20/25 | kA |
| Rated Voltage — 12 | kV |
| Three-Phase Non-Simultaneity — ≤2 | ms |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
12 kV outdoor high-voltage AC vacuum circuit breaker 630 A

Tuya Wi-Fi 16A Double Pole Smart Relay Switch L-L/L-N Wiring TOVMT 2P

KT301P Accessories

KAIWEETS KT301P Circuit Breaker Finder

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ZW32 |
| Manufacturer | Hexing |
Miniature Circuit Breakers
UL 489 3-pole miniature circuit breaker, type C curve · Ref. : HCB1U-60/3-1
Price on request
Miniature Circuit Breakers
Fixed metal-enclosed medium voltage switchgear · Ref. : XGN66-12
Price on request
Miniature Circuit Breakers
Modular miniature circuit breaker 1P/2P/3P rated 5 to 60 A · Ref. : UEB1-70
Price on request
Miniature Circuit Breakers
Indoor high-voltage vacuum circuit breaker 40.5 kV · Ref. : WEV-40.5
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details