The HIITIO HCA3-40 is a 1P+N modular arc fault detection device (AFDD) with integrated RCBO residual current protection, for protecting 240 V low-voltage electrical circuits.
Electrical features — Rated residual operating current(lΔn)30mA,100mA,300mA
Electrical features — Surge current resistance/at(8/20)us3KA
Electrical; Features — Rated frequency50Hz
Mechanical life — Storage temperature-25℃+70℃
Electrical; Features — Electrical life4,000
Electrical features — Insulation voltage(Ui)500V
Product overview
Overview. The HIITIO HCA3-40 is a 1P+N modular arc fault detection device (AFDD) combining arc fault protection with an RCBO residual current circuit breaker, compliant with IEC 62606 and IEC 61009-1. It comes in a compact housing with a total length of 115 mm.
Electrical characteristics. Rated voltage Ue of 240 V, insulation voltage Ui of 500 V, rated frequency of 50 Hz, rated impulse withstand voltage Uimp of 4 kV and surge current resistance of 3 kA (8/20 µs). The rated breaking capacity Icn and the rated operating short-circuit breaking capacity Ics are both 6 kA. The rated current In is available from 6 A to 40 A (6, 10, 16, 20, 25, 32 and 40 A), with trip curves B, C and D and rated residual operating currents IΔn of 30 mA, 100 mA or 300 mA. The RCD type is AC or A, with an electrical life of 4,000 operations and a mechanical life of 20,000 operations.
Connection and installation. Mounts on a 35 mm DIN rail. The terminals accept cable or busbar: connection capacity of 25 mm² on the input side and 16 mm² on the output side, with tightening torques of 2.5 Nm at the input and 1.2 Nm at the output.
Environment. Ambient temperature from -25 °C to +40 °C (daily average at 35 °C), storage temperature from -25 °C to +70 °C, pollution degree and IP20 protection rating.
Typical uses. Protection of low-voltage distribution circuits in electrical panels, where arc fault detection complements residual current and overcurrent protection.
The HIITIO HCA3-40 is a 1P+N modular arc fault detection device (AFDD) with integrated RCBO residual current protection, for protecting 240 V low-voltage electrical circuits.
Electrical features — Rated residual operating current(lΔn)30mA,100mA,300mA
Electrical features — Surge current resistance/at(8/20)us3KA
Electrical; Features — Rated frequency50Hz
Mechanical life — Storage temperature-25℃+70℃
Electrical; Features — Electrical life4,000
2. Datasheet extract (recorded values)
Parameter
Value
Electrical; Features — Electrical life
4,000
Electrical features — Insulation voltage(Ui)
500V
Electrical; Features — Model
Electronic
Electrical; Features — Pole
1P +N
Electrical; Features — Rate voltage(Ue)
240V
Electrical features — Rated breaking capacity (Icn)
6KA
Electrical; Features — Rated curret(In)
6A,10A, 16A, 20A,25A,32A,40A
Electrical; Features — Rated frequency
50Hz
Electrical; Features — Rated impulse withstand voltage (Uimp)
4KV
Electrical features — Rated operating short circuit breaking capacity(Ics)
6KA
Electrical; Features — Rated residual making and breaking capacity(lcn)
(2000A)
Electrical features — Rated residual operating current(lΔn)
30mA,100mA,300mA
Electrical features — RCD Type
AC,A
Electrical; Features — Standard
IEC 61009-1, GB16917.1
Electrical features — Surge current resistance/at(8/20)us
3KA
Electrical features — Trip curve
B,C,D
Installation
35mm DIN rai1
Installation — Connection capacity(input)
25m㎡
Installation — Connection capacity (output)
16m㎡
Installation — Terminal connection type
Cable, busbar
Installation — Tightening torque(input)
2.5Nm
Installation — Tightening torque(output)
1.2Nm
Mechanical life — Ambient temperature(with daily averages35℃)
-25℃+40℃
Mechanical life — Mechanical features
20,000
Mechanical life — Pollution degree
IP20
Mechanical life — Storage temperature
-25℃+70℃
Pole
Choose an option 1P+N Clear
Rated Current
Choose an option 6A 10A 16A 20A 25A 32A 40A
Alternatives and comparable products
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productHIITIO
HCA3-40
Arc fault detection device with RCBO protection, 1P+N
Electrical features — Rated residual operating current(lΔn)
30mA,100mA,300mA
Electrical features — Surge current resistance/at(8/20)us
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details