HCB2N
4-pole miniature circuit breaker, N type, up to 125 A

- Operating Temperature Range
- 40℃ ~ +70℃(fiducial temperature 30℃)
- Rated Current : 0.5~125A
- 125
- Short-circuit current rating(kA)
- 10
- According to standard
- UL489
4-pole miniature circuit breaker, N type, up to 125 A
HIITIO 4-pole miniature circuit breaker providing overcurrent and short-circuit protection, with ratings up to 125 A and compliance with UL489.
Overview. The HIITIO HCB2N is a 4-pole miniature circuit breaker designed for overcurrent protection, short-circuit protection and isolation of electrical circuits. It complies with UL489.
Main characteristics. Rated currents from 0.5 A to 125 A, nominal insulation voltage of 1000 Vac and rated impulse withstand voltage of 6 kV. Short-circuit current rating of 10 kA. The release type is hydraulic.
Service life and protection. Electrical operating life of 6000 cycles and mechanical operating life of 10000 cycles. Level of protection IP30, pollution class III. The breaker is less affected by altitude.
Connection and installation. Mounts on a 35 mm DIN rail. Wire size from 0.75 to 25 mm² (18 to 4 AWG).
Environment. Operating temperature range from -40 °C to +70 °C (reference temperature 30 °C). Relative humidity: at most 90 % at 20 °C and at most 50 % at 40 °C.
Typical uses. Protection of distribution circuits and main loop devices, including lighting, socket and industrial control applications on resistive or low-inductive loads.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for HCB2N, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| According to standard | UL489 |
| Altitude ft (m) | It is less affected by altitude |
| Assemble | 35mm DIN |
| B1 Series thermomagnet type M B2 Series hydraulic type MCB | CB |
| Class of pollution | Class III |
| Electrical operating life | 6000 |
| Function | Overcurrent protection, short circuit protection, isolation |
| Level of Protection | IP30 |
| Mechanical operating life | 10000 |
| Nominal insulation voltage(Vac) | 1000 |
| Operating Temperature Range | 40℃ ~ +70℃(fiducial temperature 30℃) |
| Pole | Choose an option 1p 2p 3p 4P Clear |
| Rated Amperage(A) | Choose an option 0.5A 1A 1.6A 2A 3A 4A 5A 6A 7A 8A 10A 13A 15A 16A 20A 25A 30A 32A 35A 40A 50A 60A 70A 80A 100A 125A |
| Rated Current : 0.5~125A | 125 |
| Rated impulse withstand voltage(kV) | 6 |
| Release Type | Hydraulic type |
| RH(relative air humidity) | 20 ℃:≤ 90%,40 ℃:≤ 50% |
| Short-circuit current rating(kA) | 10 |
| Wire (mm2) | 18~4 (0.75~25) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for HCB2N. For a missing document or a specific revision, our experts send it to you.
HIITIO 4-pole miniature circuit breaker providing overcurrent and short-circuit protection, with ratings up to 125 A and compliance with UL489.
| Parameter | Value |
|---|---|
| According to standard | UL489 |
| Altitude ft (m) | It is less affected by altitude |
| Assemble | 35mm DIN |
| B1 Series thermomagnet type M B2 Series hydraulic type MCB | CB |
| Class of pollution | Class III |
| Electrical operating life | 6000 |
| Function | Overcurrent protection, short circuit protection, isolation |
| Level of Protection | IP30 |
| Mechanical operating life | 10000 |
| Nominal insulation voltage(Vac) | 1000 |
| Operating Temperature Range | 40℃ ~ +70℃(fiducial temperature 30℃) |
| Pole | Choose an option 1p 2p 3p 4P Clear |
| Rated Amperage(A) | Choose an option 0.5A 1A 1.6A 2A 3A 4A 5A 6A 7A 8A 10A 13A 15A 16A 20A 25A 30A 32A 35A 40A 50A 60A 70A 80A 100A 125A |
| Rated Current : 0.5~125A | 125 |
| Rated impulse withstand voltage(kV) | 6 |
| Release Type | Hydraulic type |
| RH(relative air humidity) | 20 ℃:≤ 90%,40 ℃:≤ 50% |
| Short-circuit current rating(kA) | 10 |
| Wire (mm2) | 18~4 (0.75~25) |
Points to check before using HCB2N in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Nominal insulation voltage(Vac) | 1000 |
| Rated Current : 0.5~125A | 125 |
| Rated impulse withstand voltage(kV) | 6 |
| Short-circuit current rating(kA) | 10 |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of HCB2N can answer. A question is not asked when nothing is recorded to answer it.
40℃ ~ +70℃(fiducial temperature 30℃) (source: Operating Temperature Range).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
4-pole miniature circuit breaker, N type, up to 125 A

Miniature Circuit Breaker 4 Poles D

Miniature Circuit Breaker 4 Poles P

Tuya Wi-Fi 16A Double Pole Smart Relay Switch L-L/L-N Wiring TOVMT 2P

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | HCB2N |
| Manufacturer | HIITIO |
Miniature Circuit Breakers
UL 489 3-pole miniature circuit breaker, type C curve · Ref. : HCB1U-60/3-1
Price on request
Miniature Circuit Breakers
Fixed metal-enclosed medium voltage switchgear · Ref. : XGN66-12
Price on request
Miniature Circuit Breakers
Modular miniature circuit breaker 1P/2P/3P rated 5 to 60 A · Ref. : UEB1-70
Price on request
Miniature Circuit Breakers
Indoor high-voltage vacuum circuit breaker 40.5 kV · Ref. : WEV-40.5
Price on request