HCDP-3P
3-pole definite purpose contactor for HVACR 20 to 90 FLA

- Application
- HVACR
- Certificates
- UL-E246810; CSA-256361
- Number of Poles
- Choose an option 3
- Standard
- UL508, UL60947, ARI 780/790
3-pole definite purpose contactor for HVACR 20 to 90 FLA
The HIITIO HCDP-3P is a 3-pole definite purpose power contactor for HVACR applications, with a rated current of 20 to 90 FLA and a 24 to 480 Vac coil.
HIITIO HCDP-3P, 3-pole definite purpose contactor for HVACR applications — The HCDP-3P is a 3-pole contactor from the HIITIO HCDP series, intended for air conditioning, heating and refrigeration applications.
Main characteristics. The rated current is selected from 20 FLA, 25 FLA, 30 FLA, 40 FLA, 50 FLA, 60 FLA, 75 FLA or 90 FLA. The coil voltage is available in 24, 120, 208-240, 277, 380 or 480 Vac.
Voltage tolerance. The contactor pulls in reliably at 70% to 110% of Us, which accounts for line voltage fluctuation.
Standards and certifications. The HCDP-3P meets UL508, UL60947 and ARI 780/790, holds UL-E246810 and CSA-256361 certificates and is RoHS compliant.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for HCDP-3P, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Application | HVACR |
| Certificates | UL-E246810; CSA-256361 |
| Coil Voltage (Vac) | Choose an option 120 208-240 24 277 380 480 |
| Number of Poles | Choose an option 3 |
| Rated Current | Choose an option 20FLA 25FLA 30FLA 40FLA 50FLA 60FLA 75FLA 90FLA |
| Standard | UL508, UL60947, ARI 780/790 |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for HCDP-3P. For a missing document or a specific revision, our experts send it to you.
The HIITIO HCDP-3P is a 3-pole definite purpose power contactor for HVACR applications, with a rated current of 20 to 90 FLA and a 24 to 480 Vac coil.
| Parameter | Value |
|---|---|
| Application | HVACR |
| Certificates | UL-E246810; CSA-256361 |
| Coil Voltage (Vac) | Choose an option 120 208-240 24 277 380 480 |
| Number of Poles | Choose an option 3 |
| Rated Current | Choose an option 20FLA 25FLA 30FLA 40FLA 50FLA 60FLA 75FLA 90FLA |
| Standard | UL508, UL60947, ARI 780/790 |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
3-pole definite purpose contactor for HVACR 20 to 90 FLA

HCDP Series 1P Definite Purpose Contactor for HVAC and Refrigeration Application

HCDP Series 4P Definite Purpose Contactor for HVAC and Refrigeration Application

150A UL Approved Motor Control AC Contactor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | HCDP-3P |
| Manufacturer | HIITIO |
Power Contactors
1 Pole + Shunt 20A-40A Definite Purpose Contactor · Ref. : SA-1.5P
Price on request
Power Contactors
Three-pole power contactor 38 A AC-3 AC coil 50/60 Hz
Price on request
Power Contactors
Technical article: relay versus contactor differences
Price on request
Power Contactors
EPS box with integrated contactors for 1-phase/3-phase inverters · Ref. : X1/X3-EPS
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details