HIITIO HCF250B high voltage DC contactor rated 250A and 1500Vdc, with one normally open main contact (SPST-NO), for switching DC circuits in electric vehicles, energy storage and photovoltaic systems.
Ambient Operating Temperature-40°C ~ +85°C
Max. Breaking Current (Resistive Load)2000A 450VDC 1 ops
Rated CurrentChoose an option 250A
Short Circuit Current Withstanding8000A (5ms) No Smoke or Fire
Ambient Operating Humidity5% ~ 85% RH
Approvals/StandardREACH
Product overview
HIITIO HCF250B high voltage DC contactor. The HIITIO HCF250B is a 250A high voltage DC contactor with one normally open main contact (SPST-NO), designed to switch DC circuits up to 1500Vdc.
Main characteristics. Rated current of 250A, carried continuously at 85°C, maximum switching voltage of 1500Vdc and maximum resistive breaking current of 2000A at 450VDC. The component offers an optional NO auxiliary contact, a maximum operate time of 30ms and a maximum release time of 10ms. Its mechanical life is 2×10⁵ operations, and its short-circuit withstand reaches 8000A for 5ms with no smoke or fire.
Coil and power. Coil available in 12, 24 or 48VDC, with a pick-up voltage of 9VDC or less, a drop-out voltage of at least 1.2VDC and an approximate rated operating power of 6W.
Breaking technology. The ceramic sealing structure, with an H₂ mixed gas filled in the chamber, avoids arc leakage risk and provides low and stable contact resistance. The non-polarity arc extinguishing design allows safe interruption of current in both directions.
Environmental resistance. Operating temperature from -40°C to +85°C, humidity from 5% to 85% RH, functional shock of 20g and destructive shock of 50g, functional vibration of 5.79g (10 to 2000Hz). Weight approximately 415g.
Typical uses. Battery disconnect and main contactor for electric and hybrid vehicles, DC switching in energy storage systems, high voltage circuit protection in photovoltaic inverters, DC fast charging stations and industrial DC power distribution.
Integration. The contactor is REACH compliant and its specification sheet details electrical life by load voltage (450V, 800V, 1000V or 1500V). It is available on quotation from Atlas Electronics.
HIITIO HCF250B high voltage DC contactor rated 250A and 1500Vdc, with one normally open main contact (SPST-NO), for switching DC circuits in electric vehicles, energy storage and photovoltaic systems.
Ambient Operating Temperature-40°C ~ +85°C
Max. Breaking Current (Resistive Load)2000A 450VDC 1 ops
Rated CurrentChoose an option 250A
Short Circuit Current Withstanding8000A (5ms) No Smoke or Fire
Ambient Operating Humidity5% ~ 85% RH
2. Datasheet extract (recorded values)
Parameter
Value
Ambient Operating Humidity
5% ~ 85% RH
Ambient Operating Temperature
-40°C ~ +85°C
Approvals/Standard
REACH
Auxiliary Contact
Choose an option NIL SPST-NO Clear
Auxiliary Contact Type
One set of Normally Open (SPST-NO)
Coil Rated Voltage
12VDC / 24VDC / 48VDC
Coil(Vdc)
Choose an option 12 24 48
Dielectric Strength (Between Main Contacts and Coil)
Before Test ≥4000VAC (1min); After Test ≥2500VAC (1min)
Dielectric Strength (Between Open Main Contacts)
Before Test ≥3000VAC (1min); After Test ≥2500VAC (1min)
Drop-out Voltage
≥1.2VDC
Electrical Life (Resistive Load)
450V Model : 250A 450VDC 1000 ops; 800V Model : 250A 800VDC 500 ops; 1000V Model : 250A 1000VDC 500 ops, Only Breaking; 1500V Model : 50A 1500VDC 6000 ops; 50A 1500VDC 11000 ops, Only Making
Insulation Resistance (Between Main Contacts and Coil)
Before Test ≥1000MΩ (1000VDC); After Test ≥50MΩ (1000VDC)
Insulation Resistance (Between Open Main Contacts)
Before Test ≥1000MΩ (1000VDC); After Test ≥50MΩ (1000VDC)
Limiting Short-time Current
375A:10min; 500A:120s; 1000A:20s; 2500A:0.6s
Load voltage
Choose an option 450V 800V 1000V 1500V
Main Contact Type
One set of Normally Open (SPST-NO)
Max. Allowable Voltage
16VDC
Max. Breaking Current (Resistive Load)
2000A 450VDC 1 ops
Max. Switching Voltage
1500VDC
Mechanical Life
2×10⁵ ops
Operate Time
Max: 30ms
Overload Breaking (Resistive Load)
500A 450VDC 10 ops
Pick-up Voltage
≤9VDC
Rated Current
Choose an option 250A
Rated Operating Power
Approx 6W
Release Time
Max: 10ms
Shock Resistance (Destructive)
50g Half-Sine Wave 6ms
Shock Resistance (Functional)
20g Half-Sine Wave 11ms
Short Circuit Current Withstanding
8000A (5ms) No Smoke or Fire
Vibration Resistance (Functional)
5.79g (10~2000Hz, Random)
Weight
Approx 415g
Integration
Points to check before using HCF250 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40°C ~ +85°C — check it against the installation environment.
Power and communication
Coil Rated Voltage
12VDC / 24VDC / 48VDC
Drop-out Voltage
≥1.2VDC
Limiting Short-time Current
375A:10min; 500A:120s; 1000A:20s; 2500A:0.6s
Load voltage
Choose an option 450V 800V 1000V 1500V
Max. Allowable Voltage
16VDC
Max. Breaking Current (Resistive Load)
2000A 450VDC 1 ops
Max. Switching Voltage
1500VDC
Pick-up Voltage
≤9VDC
Rated Current
Choose an option 250A
Rated Operating Power
Approx 6W
Short Circuit Current Withstanding
8000A (5ms) No Smoke or Fire
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40°C ~ +85°C — check it against the installation environment.
Technical FAQ
Answers to the questions that the recorded characteristics of HCF250 can answer. A question is not asked when nothing is recorded to answer it.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productHIITIO
HCF250
250A 1500Vdc ceramic-sealed high voltage DC contactor
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details