HCF350-2500V
350A 2500Vdc High Voltage DC Contactor

- Max.Switching Voltage — 2500VDC — Rated Current
- 350A
- Rated Current
- Choose an option 350A
- Short Circuit Current Withstanding
- 8000A (5ms), No Smoke or Fire
- Ambient Operation Humidity
- 5% ~ 85% RH
350A 2500Vdc High Voltage DC Contactor
HIITIO high voltage DC contactor rated 350 A and 2500 Vdc, with a normally open main contact and an optional auxiliary contact, for switching high voltage DC circuits.
HIITIO HCF350-2500V. high voltage DC contactor — The HIITIO HCF350-2500V is a high voltage DC contactor with an SPST-NO main contact, designed to switch DC circuits up to 2500 Vdc at a rated current of 350 A.
Main characteristics. Maximum switching voltage of 2500 Vdc, rated current of 350 A, SPST-NO main contact and optional SPST-NO auxiliary contact, with an auxiliary contact range of 100 mA/8 Vdc to 2 A/30 Vdc and an auxiliary contact resistance of at most 200 mΩ at 100 mA. Maximum operate time is 50 ms and maximum release time 30 ms. Mechanical life reaches 2*10^5 operations.
Coil and control. Coil available in 12 Vdc, 24 Vdc or 48 Vdc. Pick-up voltage of at most 9 Vdc for the 12 Vdc version, 18 Vdc for the 24 Vdc version and 36 Vdc for the 48 Vdc version. Drop-out voltage of at least 1.2 Vdc, 2.4 Vdc or 4.8 Vdc depending on the rated voltage. Rated operating power of approximately 60 W at start and 5.4 W in hold.
Electrical performance. Short circuit withstanding current of 8000 A for 5 ms, with no smoke or fire. Maximum resistive breaking current of 2000 A at 1000 Vdc for one operation, and overload breaking of 1000 A at 900 Vdc for 100 operations. Limiting short-time current of 400 A for 10 min, 600 A for 90 s, 1000 A for 100 s and 2000 A for 1 s. Electrical life under resistive load of 200 operations breaking 350 A at 2500 Vdc.
Environment and mechanical ruggedness. Operation from -40 °C to +85 °C, ambient humidity from 5% to 85% RH. Destructive shock resistance of 50 g half-sine 6 ms and functional shock resistance of 20 g half-sine 11 ms, functional vibration resistance of 5.79 g (10 to 2000 Hz, random). Weight approximately 1300 g. REACH compliant.
Typical applications. Electric vehicles, rail transit, charging systems, energy storage systems and photovoltaic installations, as well as the aviation and military sectors listed by the manufacturer.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for HCF350-2500V, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Ambient Operation Humidity | 5% ~ 85% RH |
| Ambient Operation Temperature | -40°C ~ +85°C |
| Approvals/Standard | REACH |
| Auxiliary Contact | Choose an option NIL SPST-NO Clear |
| Auxiliary Contact Arrangement — One set of normally open SPST-NO — Auxiliary Contact Range | 100mA/8VDC~2A/30VDC |
| Auxiliary Contact Resistance | ≤200mΩ (at 100mA) |
| Auxiliary Contact Type | One set of normally open SPST-NO |
| Coil Rated Voltage | 12VDC/24VDC/48VDC |
| Coil(Vdc) | Choose an option 12 24 48 |
| Drop-out Voltage — ≥1.2VDC — ≥2.4VDC | ≥4.8VDC |
| Electrical Life (Resistive Load) — 2000V Model | 2500V Model |
| Electrical Life (Resistive Load) — 350A 2000VDC, 500 operations, Only Breaking | 350A 2500VDC, 200 operations, Only Breaking |
| Limiting Short-time Current | 400A:10min; 600A:90s; 1000A:100s; 2000A:1s |
| Load voltage | Choose an option 2000V 2500V |
| Main Contact Type | One set of normally open SPST-NO |
| Max. Allowable Voltage — 16VDC — 32VDC | 64VDC |
| Max. Breaking Current (Resistive Load) | 2000A 1000VDC, 1 operation; 1000A 1500VDC, 1 operation |
| Max. Switching Voltage | 2500VDC |
| Max.Switching Voltage — 2500VDC — Rated Current | 350A |
| Operate Time — Max: 50ms — Mechanical Life | 2*10^5 operations |
| Overload Breaking (Resistive Load) | 1000A 900VDC, 100 operations |
| Pick-up Voltage — ≤9VDC — ≤18VDC | ≤36VDC |
| Rated Current | Choose an option 350A |
| Rated Operating Power | Approx 60W (Start); 5.4W (Hold) |
| Rated Voltage — 12VDC — 24VDC | 48VDC |
| Release Time — Max: 30ms — Weight | Approx 1300g |
| Shock Resistance — Destructive — 50g Half-Sine Wave 6ms — Vibration Resistance — Functional | 5.79g (10~2000Hz, Random) |
| Shock Resistance — Functional — 20g Half-Sine Wave 11ms — Vibration Resistance — Functional | 5.79g (10~2000Hz, Random) |
| Short Circuit Current Withstanding | 8000A (5ms), No Smoke or Fire |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for HCF350-2500V. For a missing document or a specific revision, our experts send it to you.
HIITIO high voltage DC contactor rated 350 A and 2500 Vdc, with a normally open main contact and an optional auxiliary contact, for switching high voltage DC circuits.
| Parameter | Value |
|---|---|
| Ambient Operation Humidity | 5% ~ 85% RH |
| Ambient Operation Temperature | -40°C ~ +85°C |
| Approvals/Standard | REACH |
| Auxiliary Contact | Choose an option NIL SPST-NO Clear |
| Auxiliary Contact Arrangement — One set of normally open SPST-NO — Auxiliary Contact Range | 100mA/8VDC~2A/30VDC |
| Auxiliary Contact Resistance | ≤200mΩ (at 100mA) |
| Auxiliary Contact Type | One set of normally open SPST-NO |
| Coil Rated Voltage | 12VDC/24VDC/48VDC |
| Coil(Vdc) | Choose an option 12 24 48 |
| Drop-out Voltage — ≥1.2VDC — ≥2.4VDC | ≥4.8VDC |
| Electrical Life (Resistive Load) — 2000V Model | 2500V Model |
| Electrical Life (Resistive Load) — 350A 2000VDC, 500 operations, Only Breaking | 350A 2500VDC, 200 operations, Only Breaking |
| Limiting Short-time Current | 400A:10min; 600A:90s; 1000A:100s; 2000A:1s |
| Load voltage | Choose an option 2000V 2500V |
| Main Contact Type | One set of normally open SPST-NO |
| Max. Allowable Voltage — 16VDC — 32VDC | 64VDC |
| Max. Breaking Current (Resistive Load) | 2000A 1000VDC, 1 operation; 1000A 1500VDC, 1 operation |
| Max. Switching Voltage | 2500VDC |
| Max.Switching Voltage — 2500VDC — Rated Current | 350A |
| Operate Time — Max: 50ms — Mechanical Life | 2*10^5 operations |
| Overload Breaking (Resistive Load) | 1000A 900VDC, 100 operations |
| Pick-up Voltage — ≤9VDC — ≤18VDC | ≤36VDC |
| Rated Current | Choose an option 350A |
| Rated Operating Power | Approx 60W (Start); 5.4W (Hold) |
| Rated Voltage — 12VDC — 24VDC | 48VDC |
| Release Time — Max: 30ms — Weight | Approx 1300g |
| Shock Resistance — Destructive — 50g Half-Sine Wave 6ms — Vibration Resistance — Functional | 5.79g (10~2000Hz, Random) |
| Shock Resistance — Functional — 20g Half-Sine Wave 11ms — Vibration Resistance — Functional | 5.79g (10~2000Hz, Random) |
| Short Circuit Current Withstanding | 8000A (5ms), No Smoke or Fire |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
350A 2500Vdc High Voltage DC Contactor

350A 1500Vdc High Voltage DC Contactor

800A 1500Vdc High Voltage DC Ceramic Contactor A

200A 1500Vdc High Voltage DC Contactors

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | HCF350-2500V |
| Manufacturer | HIITIO |
Power Contactors
1 Pole + Shunt 20A-40A Definite Purpose Contactor · Ref. : SA-1.5P
Price on request
Power Contactors
Three-pole power contactor 38 A AC-3 AC coil 50/60 Hz
Price on request
Power Contactors
Technical article: relay versus contactor differences
Price on request
Power Contactors
EPS box with integrated contactors for 1-phase/3-phase inverters · Ref. : X1/X3-EPS
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details