ZJWP125A-U1
Low voltage DC contactor 150 A with magnetic blowout

- Operating Temperature
- -40°C to +60°C
- Coil Power Consumption
- Intermittent: 20-40W Continuous: 15-20W
- Rated heating current
- 150A (100% Ith)
- Storage Temperature
- -40°C to +85°C
Low voltage DC contactor 150 A with magnetic blowout
High-current 150 A DC contactor with magnetic blowout, designed to switch low voltage DC circuits up to 96 V DC.
HIITIO ZJWP125A-U1 DC contactor. The ZJWP125A-U1 is a heavy-duty DC contactor rated 150 A thermal current (100% Ith), with magnetic blowout, suitable for DC circuits up to 96 V DC.
Main characteristics. Maximum contact voltage is 48 V DC without blowout and 96 V DC with blowout. Contact voltage drop is below 40 mV at 100 A. Contact jitter time is below 4 ms for fast switching.
Durability. Service life exceeds 300,000 mechanical cycles and 100,000 electrical cycles.
Coil power and environment. Coil power consumption is 20 to 40 W intermittent and 15 to 20 W continuous. Pick-up voltage is 60% Un intermittent and 66% Un continuous, release voltage 5 to 40% Un. Operating temperature ranges from -40 °C to +60 °C, storage temperature from -40 °C to +85 °C. Weight is 430 g.
Typical uses. Electric vehicles and commercial electric trucks, large solar energy storage systems, high-capacity battery management systems (BMS), industrial DC power distribution, pre-charge and main disconnect circuits, marine, RV and heavy-duty off-grid applications.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ZJWP125A-U1, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Coil Power Consumption | Intermittent: 20-40W Continuous: 15-20W |
| Electrical Life | >100,000 cycles |
| Fast Switching | Contact jitter time <4ms |
| Low Contact Voltage Drop | <40mV @ 100A |
| Max Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Maximum Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Mechanical Life | >300,000 cycles |
| Model | ZJWP125A-U1 |
| Operating Temperature | -40°C to +60°C |
| Pick-up Voltage | Intermittent: 60% Un Continuous: 66% Un |
| Rated heating current | 150A (100% Ith) |
| Release Voltage | 5-40% Un |
| Robust Build | Weight 430g |
| Storage Temperature | -40°C to +85°C |
| Superior Lifespan | Mechanical >300,000 cycles, Electrical >100,000 cycles |
| Weight | 430g |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for ZJWP125A-U1. For a missing document or a specific revision, our experts send it to you.
High-current 150 A DC contactor with magnetic blowout, designed to switch low voltage DC circuits up to 96 V DC.
| Parameter | Value |
|---|---|
| Coil Power Consumption | Intermittent: 20-40W Continuous: 15-20W |
| Electrical Life | >100,000 cycles |
| Fast Switching | Contact jitter time <4ms |
| Low Contact Voltage Drop | <40mV @ 100A |
| Max Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Maximum Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Mechanical Life | >300,000 cycles |
| Model | ZJWP125A-U1 |
| Operating Temperature | -40°C to +60°C |
| Pick-up Voltage | Intermittent: 60% Un Continuous: 66% Un |
| Rated heating current | 150A (100% Ith) |
| Release Voltage | 5-40% Un |
| Robust Build | Weight 430g |
| Storage Temperature | -40°C to +85°C |
| Superior Lifespan | Mechanical >300,000 cycles, Electrical >100,000 cycles |
| Weight | 430g |
Points to check before using ZJWP125A-U1 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Coil Power Consumption | Intermittent: 20-40W Continuous: 15-20W |
| Low Contact Voltage Drop | <40mV @ 100A |
| Max Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Maximum Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Pick-up Voltage | Intermittent: 60% Un Continuous: 66% Un |
| Rated heating current | 150A (100% Ith) |
| Release Voltage | 5-40% Un |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of ZJWP125A-U1 can answer. A question is not asked when nothing is recorded to answer it.
-40°C to +60°C (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Low voltage DC contactor 150 A with magnetic blowout

DC Contactor 125A 96V DC High Current Low Voltage Contactor with Magnetic Blowout

Low Voltage DC Contactor 150A 96V DC High Current Contactor with Magnetic Blowout

Low Voltage DC Contactor 200A 96V DC High Current Contactor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ZJWP125A-U1 |
| Manufacturer | HIITIO |
Power Contactors
1 Pole + Shunt 20A-40A Definite Purpose Contactor · Ref. : SA-1.5P
Price on request
Power Contactors
Three-pole power contactor 38 A AC-3 AC coil 50/60 Hz
Price on request
Power Contactors
Technical article: relay versus contactor differences
Price on request
Power Contactors
EPS box with integrated contactors for 1-phase/3-phase inverters · Ref. : X1/X3-EPS
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details