AF-EMF89
Intelligent Electromagnetic Flowmeter DN10 to DN2000

- Accuracy
- 0.5%/0.3%/0.2%
- Communication
- MODBUS/HART
- Connection
- Flange/Wafer/Threaded/Clamp
- Converter Protection Class
- IP65/IP67
Intelligent Electromagnetic Flowmeter DN10 to DN2000
The Hollysys AF-EMF89 intelligent electromagnetic flowmeter measures the flow of conductive fluids in pipes from DN10 to DN2000, with an accuracy of 0.5%, 0.3% or 0.2%.
Overview. The Hollysys AF-EMF89 is an intelligent electromagnetic flowmeter for measuring the flow of conductive fluids. It is designed for high precision, high performance and a wide measuring range, with a range ratio of 1000:1.
Main characteristics. Accuracy of 0.5%, 0.3% or 0.2%. Diameters from DN10 to DN2000, flange pressures from PN6 to PN40 and medium temperature from -40 to 180 ºC. Choice of electrode materials (316L, Hc, Ti, Ta, W, Pt) and lining materials (Ne, FEP, PTFE, PU, PFA). Integrated or split structure, with flange, wafer, threaded or clamp connection.
Interfaces and communication. 4 to 20 mA output or passive pulse output. MODBUS and HART communication.
Power and environment. Power supply 220 V AC or 24 V DC. Converter protection class IP65/IP67 and sensor protection class IP65/IP67/IP68. Grounding by grounding electrode or grounding ring. Enclosure and flange material carbon steel, with 304/316/316L optional.
Installation. Front straight pipe section of 5D and rear section of 2D. No flow obstruction, almost no pressure loss. Modular converter design allowing repair without interrupting the power supply, and no moving parts.
Typical uses. Flow measurement of conductive fluids in industrial processes, with outputs compatible with control systems via MODBUS or HART. Electromagnetic compatibility compliant with GB/T 17626 and IEC 61000 specifications.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for AF-EMF89, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | 0.5%/0.3%/0.2% |
| Communication | MODBUS/HART |
| Connection | Flange/Wafer/Threaded/Clamp |
| Converter Protection Class | IP65/IP67 |
| Diameter | DN10 to DN2000 |
| Electrode material | 316L/Hc/Ti/Ta/W/Pt |
| Flange Pressure | PN6 to PN40 |
| Front Straight Pipe Section | 5D |
| Grounding Element | Grounding electrode, grounding ring |
| lining material | Ne/FEP/PTFE/PU/PFA |
| Material (Enclosure) | Carbon Steel (304/316/316L is optional) |
| Material (Flange) | Carbon Steel (304/316/316L is optional) |
| Medium temperature | -40 to 180ºC |
| Output signal | 4 to 20 mA/passive pulse |
| Power supply | 220 V AC/24 V DC |
| Rear Straight Pipe Section | 2D |
| Sensor protection class | IP65/IP67/IP68 |
| Structure | Integrated type/split type |
| Wide Range Ratio | 1000:1 |
| Wide Range Ratio 1000 | 1 |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for AF-EMF89. For a missing document or a specific revision, our experts send it to you.
The Hollysys AF-EMF89 intelligent electromagnetic flowmeter measures the flow of conductive fluids in pipes from DN10 to DN2000, with an accuracy of 0.5%, 0.3% or 0.2%.
| Parameter | Value |
|---|---|
| Accuracy | 0.5%/0.3%/0.2% |
| Communication | MODBUS/HART |
| Connection | Flange/Wafer/Threaded/Clamp |
| Converter Protection Class | IP65/IP67 |
| Diameter | DN10 to DN2000 |
| Electrode material | 316L/Hc/Ti/Ta/W/Pt |
| Flange Pressure | PN6 to PN40 |
| Front Straight Pipe Section | 5D |
| Grounding Element | Grounding electrode, grounding ring |
| lining material | Ne/FEP/PTFE/PU/PFA |
| Material (Enclosure) | Carbon Steel (304/316/316L is optional) |
| Material (Flange) | Carbon Steel (304/316/316L is optional) |
| Medium temperature | -40 to 180ºC |
| Output signal | 4 to 20 mA/passive pulse |
| Power supply | 220 V AC/24 V DC |
| Rear Straight Pipe Section | 2D |
| Sensor protection class | IP65/IP67/IP68 |
| Structure | Integrated type/split type |
| Wide Range Ratio | 1000:1 |
| Wide Range Ratio 1000 | 1 |
Answers to the questions that the recorded characteristics of AF-EMF89 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": MODBUS/HART.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Intelligent Electromagnetic Flowmeter DN10 to DN2000

Electromagnetic Flowmeter for Low Conductivity

Electromagnetic Flowmeter for Slurry & Pulp

Electromagnetic Flowmeter for Low Flow Measurement

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | AF-EMF89 |
| Manufacturer | Hollysys |
Electromagnetic Flow Meters
Insertion Electromagnetic Flowmeter
Price on request
Electromagnetic Flow Meters
DN25 to DN400 Electromagnetic Heat Flowmeter · Ref. : MFE600H
Price on request
Electromagnetic Flow Meters
Electromagnetic flow meter
Price on request
Electromagnetic Flow Meters
Remote Electromagnetic Water Flow Meter with Separate Display · Ref. : SI-3102
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details