AF-EMF8J
Electromagnetic flowmeter for slurry and pulp

- Accuracy
- 0.5%
- Communication
- MODBUS/HART
- Connection
- Flange/wafer/threaded/clamp
- Converter Protection Class
- IP65/IP67
Electromagnetic flowmeter for slurry and pulp
The Hollysys AF-EMF8J electromagnetic flowmeter measures solid-liquid two-phase fluids such as paper pulp and mineral slurries with 0.5% accuracy.
Overview. The Hollysys AF-EMF8J is an electromagnetic flowmeter designed to measure solid-liquid two-phase fluids, including paper pulp and mineral slurries. It uses multi-frequency excitation, digital noise reduction and a new filtering algorithm.
Main characteristics. 0.5% accuracy, diameters from DN10 to DN350, flange pressure from PN6 to PN40 and medium temperature from -40 to 180 ºC. The sensor is available as an integrated or split type.
Materials. Electrodes in 316L, Hc, Ti, Ta, W or Pt, lining in FEP or PU. Flanges and enclosure in carbon steel, with 304, 316 or 316L optional.
Interfaces and connectivity. 4 to 20 mA analogue output or passive pulse output, MODBUS/HART communication for integration into a supervision system.
Power and protection. 220 V AC or 24 V DC power supply. Converter protection class IP65/IP67, sensor protection class IP65/IP67/IP68.
Connection. Flange, wafer, threaded or clamp.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for AF-EMF8J, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | 0.5% |
| Communication | MODBUS/HART |
| Connection | Flange/wafer/threaded/clamp |
| Converter Protection Class | IP65/IP67 |
| Diameter | DN10 to DN350 |
| Electrode material | 316L/Hc/Ti/Ta/W/Pt |
| Flange Pressure | PN6 to PN40 |
| lining material | FEP/PU |
| Material (Enclosure) | Carbon Steel (304/316/316L is optional) |
| Material (Flange) | Carbon Steel (304/316/316L is optional) |
| Medium temperature | -40 to 180ºC |
| Output signal | 4 to 20 mA/passive pulse |
| Power supply | 220 V AC/24 V DC |
| Sensor protection class | IP65/IP67/IP68 |
| Structure | Integrated type/split type |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for AF-EMF8J. For a missing document or a specific revision, our experts send it to you.
The Hollysys AF-EMF8J electromagnetic flowmeter measures solid-liquid two-phase fluids such as paper pulp and mineral slurries with 0.5% accuracy.
| Parameter | Value |
|---|---|
| Accuracy | 0.5% |
| Communication | MODBUS/HART |
| Connection | Flange/wafer/threaded/clamp |
| Converter Protection Class | IP65/IP67 |
| Diameter | DN10 to DN350 |
| Electrode material | 316L/Hc/Ti/Ta/W/Pt |
| Flange Pressure | PN6 to PN40 |
| lining material | FEP/PU |
| Material (Enclosure) | Carbon Steel (304/316/316L is optional) |
| Material (Flange) | Carbon Steel (304/316/316L is optional) |
| Medium temperature | -40 to 180ºC |
| Output signal | 4 to 20 mA/passive pulse |
| Power supply | 220 V AC/24 V DC |
| Sensor protection class | IP65/IP67/IP68 |
| Structure | Integrated type/split type |
Answers to the questions that the recorded characteristics of AF-EMF8J can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": MODBUS/HART.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Electromagnetic flowmeter for slurry and pulp

Intelligent Electromagnetic Flowmeter

Electromagnetic Flowmeter for Low Conductivity

Electromagnetic Flowmeter for Low Flow Measurement

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | AF-EMF8J |
| Manufacturer | Hollysys |
Electromagnetic Flow Meters
Insertion Electromagnetic Flowmeter
Price on request
Electromagnetic Flow Meters
Intelligent Electromagnetic Flowmeter DN10 to DN2000 · Ref. : AF-EMF89
Price on request
Electromagnetic Flow Meters
DN25 to DN400 Electromagnetic Heat Flowmeter · Ref. : MFE600H
Price on request
Electromagnetic Flow Meters
Electromagnetic flow meter
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details