LEVEL-SENSORS
Liquid level sensor with Modbus RTU and 4-20 mA output

- Level range
- 0 to 100mm... 0 to 3000mm
- Working current
- × ≤300 mA
- BAR
- 0 to 0.05 … 0 to 50
- Beam Angle
- 12
Liquid level sensor with Modbus RTU and 4-20 mA output
Holykell level sensor for liquid level measurement, with 4-20 mA or 0-5 V analogue output and RS485 Modbus RTU communication. Measuring ranges from 2.5 m to 15 m.
Holykell level sensor. This Holykell level sensor, a liquid level transmitter, measures liquid level over ranges from 0 to 100 mm up to 0 to 3000 mm depending on the configuration.
Main characteristics. Typical accuracy of 0.5 %F.S (0.25 %F.S on request), response time of 0.5 s for the 2.5 m and 5 m ranges, 1 s for 10 m and 2 s for 15 m, adjustable from 0.5 s to 10 s with software or Modbus commands, the faster the setting, the shorter the lifetime. Distance measuring mode by default, level mode optional. Beam angle of 12 degrees, blind area up to 300 mm at 10 m and up to 500 mm at 15 m.
Outputs and connectivity. 4-20 mA output on 3 wires and RS485 Modbus RTU, or 0-5 V output on 3 wires and RS485 Modbus RTU as an option. Operates on DC 24 V supply by default, DC 12 V on request.
Power and environment. Working current up to 300 mA, working temperature from -10 C to +50 C. Product material of polypropylene with glass fiber.
Typical uses. Measurement of water, fuel and corrosive liquid levels, with readings transmitted to a PLC or supervision system via Modbus RTU.
Integration. Nut clamping, screw-in or M68 2 installation depending on the model.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for LEVEL-SENSORS, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | 0.5s (2.5 m/5 m default); 1s (10 m default); 2s (15 m default); 0.5s to10s adjustable with software or Modbus commands, the faster, the shorter the lifetime |
| Accuracy | 0.5°%F.S (typical), 0.25%F.S (by customized) |
| BAR | 0 to 0.05 … 0 to 50 |
| Beam Angle | 12 |
| Blind area | 4-20 mA/0-5 V(10 m):≤300 mm 4-20 mA/0-5 V(15 m):≤500 mm |
| EMC Standard | EN 61326-1:2013; EN 61326-2-3:2013; EN 61000-6-2:2005; EN61000-6-4:2007+A1 |
| Installation Mode | Nut clamping fixed installation, screw-in installation, M68 2 |
| inWC | 0 to 20 …0 to 20000 |
| L | D |
| Level range | 0 to 100mm... 0 to 3000mm |
| Measuring Mode | Distance mode(default), or level mode optional |
| Measuring Range | 2.5 m, 5 m, 10 m, 15 m, others on request 4-20 mA/0-5 V(2.5 m/5 m):≤200 mm |
| mH2O | 0 to 0.5…0 to 500 |
| mH2O/Fuel | 0 to 0.5 … 0 to 50 |
| Output signal | 4-20 mA(3 wires) & RS485 Modbus RTU; 0-5 V(3 wires)&RS485 Modbus RTU Optional |
| Power supply | ° ° DC 24 V(default); DC 12 V(by customized) |
| Product Material | Polypropylene + glass fiber |
| PSI | 0 to 1.0… 0 to 29 |
| Working current | × ≤300 mA |
| Working Temp | -10 C to +50 C |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for LEVEL-SENSORS. For a missing document or a specific revision, our experts send it to you.
Holykell level sensor for liquid level measurement, with 4-20 mA or 0-5 V analogue output and RS485 Modbus RTU communication. Measuring ranges from 2.5 m to 15 m.
| Parameter | Value |
|---|---|
| Response time | 0.5s (2.5 m/5 m default); 1s (10 m default); 2s (15 m default); 0.5s to10s adjustable with software or Modbus commands, the faster, the shorter the lifetime |
| Accuracy | 0.5°%F.S (typical), 0.25%F.S (by customized) |
| BAR | 0 to 0.05 … 0 to 50 |
| Beam Angle | 12 |
| Blind area | 4-20 mA/0-5 V(10 m):≤300 mm 4-20 mA/0-5 V(15 m):≤500 mm |
| EMC Standard | EN 61326-1:2013; EN 61326-2-3:2013; EN 61000-6-2:2005; EN61000-6-4:2007+A1 |
| Installation Mode | Nut clamping fixed installation, screw-in installation, M68 2 |
| inWC | 0 to 20 …0 to 20000 |
| L | D |
| Level range | 0 to 100mm... 0 to 3000mm |
| Measuring Mode | Distance mode(default), or level mode optional |
| Measuring Range | 2.5 m, 5 m, 10 m, 15 m, others on request 4-20 mA/0-5 V(2.5 m/5 m):≤200 mm |
| mH2O | 0 to 0.5…0 to 500 |
| mH2O/Fuel | 0 to 0.5 … 0 to 50 |
| Output signal | 4-20 mA(3 wires) & RS485 Modbus RTU; 0-5 V(3 wires)&RS485 Modbus RTU Optional |
| Power supply | ° ° DC 24 V(default); DC 12 V(by customized) |
| Product Material | Polypropylene + glass fiber |
| PSI | 0 to 1.0… 0 to 29 |
| Working current | × ≤300 mA |
| Working Temp | -10 C to +50 C |
Answers to the questions that the recorded characteristics of LEVEL-SENSORS can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Output signal": 4-20 mA(3 wires) & RS485 Modbus RTU; 0-5 V(3 wires)&RS485 Modbus RTU Optional.
Yes — recorded under "Response time": 0.5s (2.5 m/5 m default); 1s (10 m default); 2s (15 m default); 0.5s to10s adjustable with software or Modbus commands, the faster, the shorter the lifetime.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Liquid level sensor with Modbus RTU and 4-20 mA output

Wiring Type Ultrasonic Level Sensor

Multipurpose Capacitance Level Sensor

Submersible Level Transmitter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | LEVEL-SENSORS |
| Manufacturer | Holykell |
Level Transmitters
Submersible liquid level sensor, 0-5 m range, 0.5-4.5 V output
Price on request
Level Transmitters
60 GHz Radar Level Sensor with RS485 MODBUS RTU Output
Price on request
Level Transmitters
Deep-water level transmitter with 4-20 mA output · Ref. : MPM426WS
Price on request
Level Transmitters
Wireless ceiling-mounted light level sensor
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details