SUBMERSIBLE-LEVEL-TRANSMITTER – Submersible level transmitter with RS485 Modbus RTU output

Submersible level transmitter with RS485 Modbus RTU output

Level Transmitters

  • -40°C to +85°C
  • ±1%F.S. (± 1 °C)
  • 0 to 0.05 … 0 to 50
  • 3-5 mm
Manufacturer part number
SUBMERSIBLE-LEVEL-TRANSMITTER
Manufacturer
Holykell
Storage Temp
-40°C to +85°C
Temperature accuracy
±1%F.S. (± 1 °C)

Holykell submersible level transmitter with RS485 Modbus RTU output, for measuring liquid level in tanks or boreholes, with vented cable and IP68 rating.

Product overview

Overview. The Holykell submersible level transmitter is an immersion level sensor whose RS485 Modbus RTU digital output allows integration into a supervision system or a PLC. It measures hydrostatic pressure to derive the liquid level.

Main characteristics. Available pressure ranges run from 0-0.1 bar to 2 bar and from 0-1 m to 20 m of fuel level, with additional ranges in mH2O, inWC, PSI and bar. Accuracy is ≤ ±0.5% F.S. typical, ≤ ±0.25% F.S. optional and 0.1% F.S. by customised request at 25 °C. Zero point temperature drift is 0.01% FS/°C, full scale temperature drift 0.005% FS/°C and long-term stability ≤ ±0.2% F.S. per year. Response time is ≤ 100 ms for digital signals and the data output interval is at least 50 ms. Overload is 150% F.S. and burst pressure 500% F.S.

Connectivity and power. The sensor has 4 wires and operates from 3.6-5 V DC or 8-30 V DC. Power consumption is 2.8 mA at 24 V, 5.1 mA at 12 V and 10.1 mA at 5 V. Surge protection reaches ±2000 V on the digital output.

Environment and materials. The sensor is compatible with SUS304 stainless steel. Medium temperature ranges from -20 °C to +85 °C and storage temperature from -40 °C to +85 °C. The cable is optionally available in polyethylene (waterproof), polyurethane (diesel proof) or FEP (anti-corrosive for gasoline). The electrical connection is a fixed cable with vented tube, IP68 rated. It is certified ATEX (II 1G Ex ia IIC), IECEx, RoHS and CE.

Typical uses. The transmitter suits level measurement of water, diesel or gasoline fuel and corrosive liquids in tanks, wells and boreholes, for example tank monitoring connected to a PLC via RS485 Modbus RTU.

See all specifications

Highlights

  • BAR: 0 to 0.05 … 0 to 50
  • Blind Zone of Probe: 3-5 mm
  • Burst Pressure: 500% F.S.
  • Certificate: ATEX (II 1G Ex ia IIC), IECEx, RoHS and CE
  • Data overtime interval: ≥50ms
  • Electrical Connection: Fixed cable with vented tube, IP68 rated

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Level Transmitters
Request a quote