The Hongfa UECAN22 is a 2NO+2NC auxiliary contactor from the UECAN series, intended for switching control circuits up to 690 V. It mounts on a 35 mm DIN rail.
Average Hold-in Power Consumption in VA9 VA 50/60 Hz (at 25 °C)
[Ith] Conventional Free Air Thermal Current10 A (at ≤60 °C)
Minimum Switching Current5mA
Mounting SupportScrew; 35mm DIN Rail
Number of Units in Package 11 pcs
Number of Units in Package 250 pcs
Product overview
Overview. The Hongfa UECAN22 is a contactor relay from the UECAN series, an auxiliary contactor designed for control circuits. It has four contacts, two normally open and two normally closed.
Main characteristics. Conventional free air thermal current of 10 A at up to 60 °C, rated operational voltage up to 690 V and rated insulation voltage of 690 V. Rated impulse withstand voltage of 6 kV. Associated fuse rating of 10 A gG conforming to IEC 60947-5-1. Insulation resistance above 10 MΩ. Mechanical durability of 10 million cycles. Minimum switching current of 5 mA at a minimum switching voltage of 17 V.
Control voltage. AC 50/60 Hz coil available for 24, 36, 48, 110, 220…230 and 380 V. Operational range from 0.85 to 1.1 Us and drop-out range from 0.2 to 0.75 Us. Average inrush power of 70 VA and average hold-in power of 9 VA at 25 °C.
Operating times. NO contacts: closing 12 to 22 ms, opening 4 to 35 ms. NC contacts: opening 4 to 19 ms, closing 6 to 40 ms. Non-overlap time of 1.5 ms. Maximum operating rate of 1200 cycles per hour electrical and 7200 cycles per hour mechanical.
Power supply and environment. Operating ambient temperature from -40 to 60 °C, with derating from 60 to 70 °C. Storage from -60 to 80 °C. Operating altitude up to 3000 m without derating. IP20 degree of protection on the front face according to IEC 60529.
Mounting and connection. Mounting on a 35 mm DIN rail or by screw. Screw clamp terminals with a tightening torque of 1.2 N·m. Dimensions of 45 × 74 × 80 mm, weight of 0.30 kg.
Typical uses. Control of power circuits in electrical cabinets, according to utilisation categories AC-15 (A600) and DC-13 (P600).
Compliance. Standards GB/T 14048.5, IEC/EN 60947-5-1 and BS EN 60947-5-1. Certifications CCC, CE and UKCA. RoHS, REACh compliant and mercury free.
The Hongfa UECAN22 is a 2NO+2NC auxiliary contactor from the UECAN series, intended for switching control circuits up to 690 V. It mounts on a 35 mm DIN rail.
Average Hold-in Power Consumption in VA9 VA 50/60 Hz (at 25 °C)
[Ith] Conventional Free Air Thermal Current10 A (at ≤60 °C)
Minimum Switching Current5mA
Mounting SupportScrew; 35mm DIN Rail
Number of Units in Package 11 pcs
2. Datasheet extract (recorded values)
Parameter
Value
Application
Control circuit
Associated Fuse Rating
10 A gG conforming to IEC 60947-5-1
Average Hold-in Power Consumption in VA
9 VA 50/60 Hz (at 25 °C)
Average Inrush Power in VA
70 VA 50/60 Hz (at 25 °C)
China RoHS Regulation
Conforming
Control Circuit Voltage Limits
0.85...1.1 Us (-40…60 °C): operational AC 50/60 Hz; 0.2...0.75 Us (-40…60 °C): drop-out AC 50/60 Hz
Depth
80 mm
Device Short Name
UECAN22
EU RoHS Directive
Conforming
Height
74 mm
[Icw] Rated Short-time Withstand Current
140 A ≤40 °C - 100ms; 120 A ≤40 °C – 500ms; 100 A ≤40 °C – 1s
Insulation Resistance
> 10 MΩ
IP Degree of Protection
IP20 front face conforming to IEC 60529
[Ith] Conventional Free Air Thermal Current
10 A (at ≤60 °C)
Maximum Operating Rate
Electrical: 1200 cycs/h; Mechanical: 7200 cycs/h
Mechanical Durability
10 M cycles
Mercury Free
Yes
Minimum Switching Current
5mA
Minimum Switching Voltage
17 V
Mounting Support
Screw; 35mm DIN Rail
Net weight
0.30 kg
Non-overlap time
1.5 ms
Number of Units in Package 1
1 pcs
Number of Units in Package 2
50 pcs
Operating Altitude
0...3000 m without derating
Operating Time
NO: 12...22 ms closing, 4...35 ms opening; NC: 4...19 ms opening, 6...40 ms closing
Package 1 Height
8.3 cm
Package 1 Length
7.8 cm
Package 1 Weight
0.35 kg
Package 1 Width
4.8 cm
Package 2 Height
19.5 cm
Package 2 Length
41.0 cm
Package 2 Weight
16.8 kg
Package 2 Width
26.0 cm
Permissible Ambient Air; Temperature Around the Device
-40…60 °C for normal operating; 60…70 °C with derating (for operation in the range of Us...1.1Us); Storage: -60…80 °C
Pole Contact Composition
2NO+2NC
Product Certifications
CCC,CE,UKCA
Product or Component Type
Contactor Relay
Product Series
UECAN
REACh Regulation
Conforming
RoHS Exemption Information
Yes
Standards
GB/T 14048.5,IEC/EN 60947-5-1,BS EN 60947-5-1
Tightening torque
10.7 lb.in (1.2 N·m) - on screw clamp terminals - with screwdriver flat Ø 6 mm; 10.7 lb.in (1.2 N·m) - on screw clamp terminals - with screwdriver Philips No 2
[Ue]Rated Operational Voltage
≤ 690 V
[Ui] Rated Insulation Voltage
690 V
[Uimp] Rated Impulse Withstand Voltage
6 kV
Unit Type of Package 1
1 box
Unit Type of Package 2
1 carton
[Us] Control Circuit Voltage; (AC 50/60Hz)
Voltage (V): 24 36 48 110 220…230 380
Utilisation Category
AC-15 (A600); DC-13 (P600)
Width
45 mm