iWSN-200U – 433 MHz wireless data concentrator with RS-232/RS-485 port

433 MHz wireless data concentrator with RS-232/RS-485 port

Submeters

  • -25 ~ +75°C
  • 1W Max
  • 433MHz
  • -30 ~ +80°C
Manufacturer part number
IWSN-200U
Manufacturer
ICP DAS
Operating Temperature
-25 ~ +75°C
Consumption
1W Max

iWSN 433 MHz wireless data concentrator with RS-232/RS-485 serial port, receiving data from up to 31 iWSN sensors and exposing it over Modbus RTU slave.

Product overview

Overview. The iWSN-200U is an iWSN wireless data concentrator from ICP DAS. It receives and buffers the data of 31 iWSN sensors over a 433 MHz radio interface and makes them available on one serial interface, RS-232 or RS-485, the two interfaces cannot be used simultaneously.

Main characteristics. The module supports 16 radio channels, selected by rotary switch, and 8 groups of IDs. It has a 0 dBi omni-directional antenna with an RP-SMA male connector and an ANT-Base-02 extension cable of 1.5 metres. Line-of-sight range is 100 m, with a transmission power of 9±1 dBm (PA off) or 18±1 dBm (PA on).

Interfaces and connectivity. The Modbus RTU protocol in slave mode lets a PLC or supervisory system read sensor data through the RS-485 or RS-232 port. Baud rates range from 1200 to 115200 bps, format N81. Status indicators are one Power LED, one RF_Tx LED and one RF_Rx LED.

Power and environment. The module operates from +10 to +30 VDC, with a maximum consumption of 1 W. It mounts on DIN rail. Operating temperature is -25 to +75 °C and humidity tolerance is 10 to 90 % RH, non-condensing. It meets ESD (IEC 61000-4-2, ±4 kV contact), EFT (IEC 61000-4-4, ±1 kV) and surge (IEC 61000-4-5, ±1 kV) tests.

Typical uses. The iWSN-200U suits collecting wireless sensor measurements into a PLC or a Modbus RTU supervision system, for example for monitoring meters or sensors distributed across an installation.

Integration. It works with the iWSN sensor range from ICP DAS. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Baud rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200bps, N81
  • Channels: 0 ~ 15 (confi gured by rotary switch)
  • Connector: RP-SMA Male (Plug)
  • Consumption: 1W Max
  • Dimensions (mm): 10 x 108 (Ø x L)
  • EFT (IEC 61000-4-4): +/- 1kV

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -25 ~ +75°C — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Submeters
Request a quote