BWDK-326 – Dry type transformer temperature controller

Dry type transformer temperature controller

Temperature Controllers

  • -30.0℃~240.0℃
  • 50Hz OR 60Hz(±2Hz)
  • <95% (25ºC)
  • -20ºC~+55ºC
Manufacturer part number
BWDK-326
Manufacturer
INNO
Temperature range
-30.0℃~240.0℃
Working frequency rate
50Hz OR 60Hz(±2Hz)

INNO BWDK-326 temperature controller for dry type transformers, monitoring winding temperature with PT100 sensors and driving alarm, trip relay and fan cooling.

Product overview

INNO BWDK-326 is a temperature controller for dry type transformers, designed to monitor winding temperature and protect the transformer against overheating. Main characteristics — The controller uses PT100 platinum resistance sensors, with a measuring range of -30.0 °C to 240.0 °C, a resolution of 0.1 °C and an accuracy of ±1 %FS. The digital display shows the maximum temperature in real time. Interfaces and outputs — The base model includes an over-temperature alarm and a trip relay, with a control output capacity of 5 A/250 VAC and 5 A/30 VDC, and a fan output of 5 A/250 VAC. Available variants add a 4-20 mA analog output, RS485 or RS232 communication, an ambient temperature sensor or an iron core temperature sensor. Power and environment — Power supply of 220 VAC (+10%, -15%), 50 Hz or 60 Hz (±2 Hz), power dissipation of 8 W maximum, ambient temperature from -20 °C to +55 °C and humidity below 95% (25 °C). Compact plastic enclosure for embedded panel mounting, 160 × 80 × 120 mm, with a 153 × 77 mm panel cutout. Typical uses — The controller starts forced air cooling by fan and trips the transformer at critical temperature, which reduces thermal stress on the insulation. The RS485 and RS232 variants allow remote monitoring and integration into a SCADA system. Compliance — Built to the JB/T 7631 standard, ISO 9001 quality system, EMC standards IEC 61000-4 and GB/T 17626, CE marking (EMC and low voltage directives) and RoHS compliance.

See all specifications

Highlights

  • Alarm: Over-temperature alarm activates at preset limit to alert operators
  • Ambient Humidity: <95% (25ºC)
  • Ambient temperature: -20ºC~+55ºC
  • Annually: Test sensor accuracy and perform system calibration
  • As needed: Verify sensor cable connections and inspect for damage
  • BWDK-326E: All 326D functions + 4-20mA analog output for SCADA system integration