KEW_1052
True RMS handheld multimeter 6000 counts

- Detection Mode
- MEAN/True RMS (switch)
- Dimension
- 192(L)×90(W)×49(D) mm
True RMS handheld multimeter 6000 counts
The KEW 1052 is a Kyoritsu handheld multimeter with True RMS measurement, designed for precision electrical measurements in industrial environments. It measures voltage, current, resistance, capacitance, frequency and temperature.
Multimeter. The Kyoritsu KEW 1052 is a handheld multimeter with True RMS or MEAN detection mode, selectable by switch. It features a 6000-count display and a basic DC voltage accuracy of ±0.09% rdg ±2 dgt.
Measurements. It measures AC and DC voltage up to 1000 V, AC and DC current up to 10 A, resistance up to 60 MΩ, capacitance up to 1000 µF, frequency up to 99.99 kHz, and temperature from -50 to 600 °C with a K-type temperature probe. It also includes a diode test and a continuity buzzer.
Safety. Compliant with IEC 61010-1 CAT IV 600 V and CAT III 1000 V, pollution degree 2, and with the EMC standard IEC 61326-1. A terminal shutter prevents incorrect insertion of test leads into current terminals.
Functions. Data hold (D/H), auto hold (A/H), range hold (R/H), maximum, minimum and average value functions, save to memory and LCD backlight. Data can be stored and, with the optional USB communication set 8241, transferred and monitored live on a PC.
Power and use. Powered by four R6/LR6 (1.5 V) batteries, with auto power off after approximately 20 minutes. Operating temperature range from -10 to 55 °C. Suited to maintenance and electrical inspection work on industrial sites.
Accessories. Supplied with test leads 7220A and fuses 8926 and 8927. Clamp sensors (8115, 8121 to 8123, 8146 to 8148), temperature probes (8405, 8407, 8408) and carrying case 9154 are available as options.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for KEW_1052, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC A [True RMS] | 600.0/6000µA/60.00/440.0mA/6.000/10.00A; ±0.75%rdg±5dgt (Basic accuracy) |
| AC V [MEAN] | 600.0mV/6.000/60.00/600.0/1000V; (Input impedance: 10MΩ <200pF [600mV], 11MΩ <50pF [6V], 10MΩ <50pF [60/600/1000V]); ±0.5%rdg±5dgt (Basic accuracy) |
| AC V [True RMS] | 600.0mV/6.000/60.00/600.0/1000V; (Input impedance: 10MΩ <200pF [600mV], 11MΩ <50pF [6V], 10MΩ <50pF [60/600/1000V]); ±0.5%rdg±5dgt (Basic accuracy) |
| Accessories | 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; Blank cover |
| Applicable Standards | IEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC) |
| Capacitance | 10.00/100.0nF/1.000/10.00/100.0/1000µF; ±2%rdg±5dgt (Basic accuracy) |
| Continuity buzzer | 600.0Ω (The buzzer turns on at resistances lower than 50±30Ω ) |
| DC A | 600.0/6000µA/60.00/440.0mA/6.000/10.00A; ±0.2%rdg±2dgt (Basic accuracy) |
| DC V | 600.0mV/6.000/60.00/600.0/1000V; (Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V]); ±0.09%rdg±2dgt (Basic accuracy) |
| Detection Mode | MEAN/True RMS (switch) |
| Dimension | 192(L)×90(W)×49(D) mm |
| Diode test | 2.000V; ±1%rdg±2dgt; Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current) |
| Frequency | 10.00 to 99.99/90.0 to 999.9Hz/0.900 to 9.999/9.00 to 99.99kHz; ±0.02%rdg±1dgt (Basic accuracy) |
| &Omega | 600.0Ω /6.000/60.00/600.0kΩ /6.000/60.00MΩ ±0.4%rdg±1dgt (Basic accuracy) |
| Optional Accessories | 7234 (Alligator clip); 8241 (USB Communication set); 8115 (AC/DC Clamp Sensor); 8121 (Load current Clamp Sensor); 8122 (Load current Clamp Sensor); 8123 (Load current Clamp Sensor); 8146 (Leakage & Load current Clamp Sensor); 8147 (Leakage & Load current Clamp Sensor); 8148 (Leakage & Load current Clamp Sensor); 7146 (Banana Ø 4 adjuster plug); 8405 (Temperature probe); 8407 (Temperature probe); 8408 (Temperature probe); 9154 (Carrying case) |
| Other Functions | Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H), Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *; Zero Adjustment (Capacitor, Resistance), Save to Memory *, LCD backlight |
| Power Source | R6/LR6 (1.5V)×4; (Auto power off: Approx. 20 minutes) |
| Product Catalog | KEW 1052 Product Catalog (English)(6.41 MB) KEW 1052 Product Catalog (Arabic)(4.64 MB) KEW 1052 Product Catalog (French)(4.47 MB) KEW 1052 Product Catalog (Indonesian)(4.21 MB) KEW 1052 Product Catalog (Spanish)(4.50 MB) KEW 1052 Product Catalog (Thai)(4.29 MB) KEW 1052 Product Catalog (Vietnamese)(4.24 MB) |
| Temperature | -50 to 600º C; ±2%rdg±2º C (with the use of K-type Temperature probe) |
| Weight | Approx. 570g (including batteries and blank cover) |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for KEW_1052. For a missing document or a specific revision, our experts send it to you.
The KEW 1052 is a Kyoritsu handheld multimeter with True RMS measurement, designed for precision electrical measurements in industrial environments. It measures voltage, current, resistance, capacitance, frequency and temperature.
| Parameter | Value |
|---|---|
| AC A [True RMS] | 600.0/6000µA/60.00/440.0mA/6.000/10.00A; ±0.75%rdg±5dgt (Basic accuracy) |
| AC V [MEAN] | 600.0mV/6.000/60.00/600.0/1000V; (Input impedance: 10MΩ <200pF [600mV], 11MΩ <50pF [6V], 10MΩ <50pF [60/600/1000V]); ±0.5%rdg±5dgt (Basic accuracy) |
| AC V [True RMS] | 600.0mV/6.000/60.00/600.0/1000V; (Input impedance: 10MΩ <200pF [600mV], 11MΩ <50pF [6V], 10MΩ <50pF [60/600/1000V]); ±0.5%rdg±5dgt (Basic accuracy) |
| Accessories | 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; Blank cover |
| Applicable Standards | IEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC) |
| Capacitance | 10.00/100.0nF/1.000/10.00/100.0/1000µF; ±2%rdg±5dgt (Basic accuracy) |
| Continuity buzzer | 600.0Ω (The buzzer turns on at resistances lower than 50±30Ω ) |
| DC A | 600.0/6000µA/60.00/440.0mA/6.000/10.00A; ±0.2%rdg±2dgt (Basic accuracy) |
| DC V | 600.0mV/6.000/60.00/600.0/1000V; (Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V]); ±0.09%rdg±2dgt (Basic accuracy) |
| Detection Mode | MEAN/True RMS (switch) |
| Dimension | 192(L)×90(W)×49(D) mm |
| Diode test | 2.000V; ±1%rdg±2dgt; Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current) |
| Frequency | 10.00 to 99.99/90.0 to 999.9Hz/0.900 to 9.999/9.00 to 99.99kHz; ±0.02%rdg±1dgt (Basic accuracy) |
| &Omega | 600.0Ω /6.000/60.00/600.0kΩ /6.000/60.00MΩ ±0.4%rdg±1dgt (Basic accuracy) |
| Optional Accessories | 7234 (Alligator clip); 8241 (USB Communication set); 8115 (AC/DC Clamp Sensor); 8121 (Load current Clamp Sensor); 8122 (Load current Clamp Sensor); 8123 (Load current Clamp Sensor); 8146 (Leakage & Load current Clamp Sensor); 8147 (Leakage & Load current Clamp Sensor); 8148 (Leakage & Load current Clamp Sensor); 7146 (Banana Ø 4 adjuster plug); 8405 (Temperature probe); 8407 (Temperature probe); 8408 (Temperature probe); 9154 (Carrying case) |
| Other Functions | Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H), Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *; Zero Adjustment (Capacitor, Resistance), Save to Memory *, LCD backlight |
| Power Source | R6/LR6 (1.5V)×4; (Auto power off: Approx. 20 minutes) |
| Product Catalog | KEW 1052 Product Catalog (English)(6.41 MB) KEW 1052 Product Catalog (Arabic)(4.64 MB) KEW 1052 Product Catalog (French)(4.47 MB) KEW 1052 Product Catalog (Indonesian)(4.21 MB) KEW 1052 Product Catalog (Spanish)(4.50 MB) KEW 1052 Product Catalog (Thai)(4.29 MB) KEW 1052 Product Catalog (Vietnamese)(4.24 MB) |
| Temperature | -50 to 600º C; ±2%rdg±2º C (with the use of K-type Temperature probe) |
| Weight | Approx. 570g (including batteries and blank cover) |
Answers to the questions that the recorded characteristics of KEW_1052 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Optional Accessories": 7234 (Alligator clip); 8241 (USB Communication set); 8115 (AC/DC Clamp Sensor); 8121 (Load current Clamp Sensor); 8122 (Load current Clamp Sensor); 8123 (Load current Clamp Sensor); 8146 (Leakage & Load current Clamp Sensor); 8147 (Leakage & Load current Clamp Sensor); 8148 (Leakage & Load current Clamp Sensor); 7146 (Banana Ø 4 adjuster plug); 8405 (Temperature probe); 8407 (Temperature probe); 8408 (Temperature probe); 9154 (Carrying case).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
True RMS handheld multimeter 6000 counts

KEW 1051

KEW 1061

KEW 1062

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | KEW_1052 |
| Manufacturer | Kyoritsu |
Handheld Multimeters
True RMS handheld multimeter 6000 counts with K-type temperature · Ref. : KEW_1051
Price on request
Handheld Multimeters
Handheld 2-channel 10 MHz oscilloscope, multimeter and DDS generator · Ref. : 2C23T
Price on request
Handheld Multimeters
Optical multimeter with 800nm-1700nm power meter and 650nm VFL
Price on request
Handheld Multimeters
6000-Count Digital Multimeter with NCV Detection · Ref. : NF-628
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details