KEW_1062
Industrial handheld TRMS multimeter 50,000 counts

- Large data internal memory KEW 1062
- 10,000 data (logging), 100 data (manual)
- Detection Mode
- MEAN/True RMS (switch)
- Dimension
- 192(L)×90(W)×49(D) mm
- DUTY
- 10 to 90%; ±1%rdg
Industrial handheld TRMS multimeter 50,000 counts
The Kyoritsu KEW 1062 handheld multimeter measures voltage, current, resistance, frequency and capacitance with 0.02% DC basic accuracy for industrial use.
Overview. The Kyoritsu KEW 1062 is a TRMS handheld digital multimeter designed for electrical measurements in industrial environments, with a 50,000-count display.
Main characteristics. DC voltage basic accuracy of ±0.02% rdg ±2 dgt, selectable True RMS or MEAN detection mode, AC bandwidth from 10 Hz to 100 kHz, Peak Hold with a 250 µs response time and a low-pass filter for motor drive measurements.
Measurement functions. DC and AC voltage up to 1000 V, DC and AC current up to 10 A, resistance up to 50 MΩ, frequency, duty cycle ratio, capacitance up to 50 mF, decibels (dBV, dBm), continuity check, diode test and LowPower Ω mode for sensitive electronic circuits. Temperature measurement with K-type probe from -200 to 1372 °C.
Memory and connectivity. Internal memory of 10,000 data in logging mode and 100 data in manual mode. Data download and live monitoring on a PC via the USB interface with the optional 8241 communication set, up to 32,767 data transferable.
Power and environment. Powered by four R6/LR6 1.5 V batteries, automatic power off after approximately 20 minutes. Operating temperature range from -20 to 55 °C. Dimensions 192 × 90 × 49 mm, weight approximately 570 g including batteries and blank cover.
Safety. Complies with IEC 61010-1 CAT IV 600 V and CAT III 1000 V, pollution degree 2, and with the EMC standard IEC 61326-1. Terminal shutters prevent incorrect insertion of test leads into current terminals.
Typical uses. Maintenance and checking of industrial electrical and electronic circuits, measurements on motor drives thanks to the low-pass filter, and checking of temperature sensors with a K-type probe.
Accessories. Test leads 7220A and fuses 8926 (440 mA/1000 V) and 8927 (10 A/1000 V) supplied. Clamp sensors 8115, 8121, 8122, 8123, 8146, 8147 and 8148, temperature probes 8405, 8407 and 8408, and case 9154 available as options.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for KEW_1062, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC A [MEAN] | 500.00/5000.0µA/50.000/500.00mA/ 5.0000/10.000A; ±1.5%rdg±20dgt (Basic accuracy) |
| AC A [True RMS] | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A; ±0.75%rdg±20dgt (Basic accuracy) |
| AC V [MEAN] | 50.000/500.00mV/ 5.0000/50.000/500.00/1000.0V; (Input impedance:11MΩ <50pF [50/500mV/5V],10MΩ <50pF [50/500/1000V]); ±1%rdg±30dgt (Basic accuracy) |
| AC V [True RMS] | 50.000/500.00mV/5.0000/50.000/500.00/1000.0V; (Input impedance: 11MΩ <50pF [50/500mV/5V], 10MΩ <50pF [50/500/1000V]); ±0.4%rdg±30dgt (Basic accuracy) |
| Accessories | 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; B lank cover |
| Applicable Standards | IEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC) |
| Capacitance | 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF; ±1%rdg±5dgt (Basic accuracy) |
| Continuity buzzer | 500.0Ω (The buzzer turns on at resistances lower than 100±50Ω ) |
| DC A | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A; ±0.2%rdg±5dgt (Basic accuracy) |
| DC V | 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V; (Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V]); ±0.02%rdg±2dgt (Basic accuracy) |
| DCA+ACA | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A; ±1%rdg±10dgt (Basic accuracy) |
| DCV+ACV | 5.0000/50.000/500.00/1000.0V; (Input impedance: 11MΩ <50pF [5V], 10MΩ <50pF [50/500/1000V]); ±0.5%rdg±10dgt (Basic accuracy) |
| Detection Mode | MEAN/True RMS (switch) |
| Dimension | 192(L)×90(W)×49(D) mm |
| Diode test | 2.4000V; ±1%rdg±2dgt; Open curcuit voltage: <5V (Approx. 0.5mA Measuring Current) |
| DUTY | 10 to 90%; ±1%rdg |
| Frequency | 2.000 to 9.999/9.00 to 99.99/90.0 to 999.9Hz/0.900 to 9.999/9.00 to 99.99kHz; ±0.02%rdg±1dgt (Basic accuracy) |
| Large data internal memory KEW 1062 | 10,000 data (logging), 100 data (manual) |
| LowPower-&Omega | 5.000/50.00/500.0kΩ /5.000MΩ ±0.2%rdg±3dgt (Basic accuracy) |
| Measurement functions | DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature; Capacitor, Duty cycle ratio, Decibel (dBV, dBm), Continuity Check, Diode Test, LowPower-&Omega |
| &Omega | 500.00Ω /5.0000/50.000/500.00kΩ /5.0000/50.000MΩ ±0.05%rdg±2dgt (Basic accuracy) |
| Optional Accessories | 7234 (Alligator clip); 8241 (USB Communication set); 8115 (AC/DC Clamp Sensor); 8121 (Load current Clamp Sensor); 8122 (Load current Clamp Sensor); 8123 (Load current Clamp Sensor); 8146 (Leakage & Load current Clamp Sensor); 8147 (Leakage & Load current Clamp Sensor); 8148 (Leakage & Load current Clamp Sensor); 7146 (Banana Ø 4 adjuster plug); 8405 (Temperature probe); 8407 (Temperature probe); 8408 (Temperature probe); 9154 (Carrying case) |
| Other Functions | Data Hold (D/H), Auto Hold (A/H), Peak Hold (P/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN); Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight |
| Power Source | R6/LR6 (1.5V)×4; (Auto power off: approx. 20 minutes) |
| Product Catalog | KEW 1062 Product Catalog (English)(6.41 MB) KEW 1062 Product Catalog (Arabic)(4.64 MB) KEW 1062 Product Catalog (French)(4.47 MB) KEW 1062 Product Catalog (Indonesian)(4.21 MB) KEW 1062 Product Catalog (Spanish)(4.50 MB) KEW 1062 Product Catalog (Thai)(4.29 MB) KEW 1062 Product Catalog (Vietnamese)(4.24 MB) |
| Temperature | -200 to 1372º C; ±1%rdg±1.5º C; -328 to 2501.6º F; ±1%rdg±2.0º F (with the use of K-type Temperature probe) |
| Weight | Approx. 570g (including batteries and blank cover) |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for KEW_1062. For a missing document or a specific revision, our experts send it to you.
The Kyoritsu KEW 1062 handheld multimeter measures voltage, current, resistance, frequency and capacitance with 0.02% DC basic accuracy for industrial use.
| Parameter | Value |
|---|---|
| AC A [MEAN] | 500.00/5000.0µA/50.000/500.00mA/ 5.0000/10.000A; ±1.5%rdg±20dgt (Basic accuracy) |
| AC A [True RMS] | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A; ±0.75%rdg±20dgt (Basic accuracy) |
| AC V [MEAN] | 50.000/500.00mV/ 5.0000/50.000/500.00/1000.0V; (Input impedance:11MΩ <50pF [50/500mV/5V],10MΩ <50pF [50/500/1000V]); ±1%rdg±30dgt (Basic accuracy) |
| AC V [True RMS] | 50.000/500.00mV/5.0000/50.000/500.00/1000.0V; (Input impedance: 11MΩ <50pF [50/500mV/5V], 10MΩ <50pF [50/500/1000V]); ±0.4%rdg±30dgt (Basic accuracy) |
| Accessories | 7220A (Test leads); 8926 (Fuse [440mA/1000V])×1 (included); 8927 (Fuse [10A/1000V])×1 (included); Batteries; Instruction manual; B lank cover |
| Applicable Standards | IEC 61010-1 CAT IV 600V / CAT III 1000V Pollution degree 2; IEC 61010-031, IEC 61326-1 (EMC) |
| Capacitance | 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF; ±1%rdg±5dgt (Basic accuracy) |
| Continuity buzzer | 500.0Ω (The buzzer turns on at resistances lower than 100±50Ω ) |
| DC A | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A; ±0.2%rdg±5dgt (Basic accuracy) |
| DC V | 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V; (Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V]); ±0.02%rdg±2dgt (Basic accuracy) |
| DCA+ACA | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A; ±1%rdg±10dgt (Basic accuracy) |
| DCV+ACV | 5.0000/50.000/500.00/1000.0V; (Input impedance: 11MΩ <50pF [5V], 10MΩ <50pF [50/500/1000V]); ±0.5%rdg±10dgt (Basic accuracy) |
| Detection Mode | MEAN/True RMS (switch) |
| Dimension | 192(L)×90(W)×49(D) mm |
| Diode test | 2.4000V; ±1%rdg±2dgt; Open curcuit voltage: <5V (Approx. 0.5mA Measuring Current) |
| DUTY | 10 to 90%; ±1%rdg |
| Frequency | 2.000 to 9.999/9.00 to 99.99/90.0 to 999.9Hz/0.900 to 9.999/9.00 to 99.99kHz; ±0.02%rdg±1dgt (Basic accuracy) |
| Large data internal memory KEW 1062 | 10,000 data (logging), 100 data (manual) |
| LowPower-&Omega | 5.000/50.00/500.0kΩ /5.000MΩ ±0.2%rdg±3dgt (Basic accuracy) |
| Measurement functions | DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature; Capacitor, Duty cycle ratio, Decibel (dBV, dBm), Continuity Check, Diode Test, LowPower-&Omega |
| &Omega | 500.00Ω /5.0000/50.000/500.00kΩ /5.0000/50.000MΩ ±0.05%rdg±2dgt (Basic accuracy) |
| Optional Accessories | 7234 (Alligator clip); 8241 (USB Communication set); 8115 (AC/DC Clamp Sensor); 8121 (Load current Clamp Sensor); 8122 (Load current Clamp Sensor); 8123 (Load current Clamp Sensor); 8146 (Leakage & Load current Clamp Sensor); 8147 (Leakage & Load current Clamp Sensor); 8148 (Leakage & Load current Clamp Sensor); 7146 (Banana Ø 4 adjuster plug); 8405 (Temperature probe); 8407 (Temperature probe); 8408 (Temperature probe); 9154 (Carrying case) |
| Other Functions | Data Hold (D/H), Auto Hold (A/H), Peak Hold (P/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN); Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight |
| Power Source | R6/LR6 (1.5V)×4; (Auto power off: approx. 20 minutes) |
| Product Catalog | KEW 1062 Product Catalog (English)(6.41 MB) KEW 1062 Product Catalog (Arabic)(4.64 MB) KEW 1062 Product Catalog (French)(4.47 MB) KEW 1062 Product Catalog (Indonesian)(4.21 MB) KEW 1062 Product Catalog (Spanish)(4.50 MB) KEW 1062 Product Catalog (Thai)(4.29 MB) KEW 1062 Product Catalog (Vietnamese)(4.24 MB) |
| Temperature | -200 to 1372º C; ±1%rdg±1.5º C; -328 to 2501.6º F; ±1%rdg±2.0º F (with the use of K-type Temperature probe) |
| Weight | Approx. 570g (including batteries and blank cover) |
Answers to the questions that the recorded characteristics of KEW_1062 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Optional Accessories": 7234 (Alligator clip); 8241 (USB Communication set); 8115 (AC/DC Clamp Sensor); 8121 (Load current Clamp Sensor); 8122 (Load current Clamp Sensor); 8123 (Load current Clamp Sensor); 8146 (Leakage & Load current Clamp Sensor); 8147 (Leakage & Load current Clamp Sensor); 8148 (Leakage & Load current Clamp Sensor); 7146 (Banana Ø 4 adjuster plug); 8405 (Temperature probe); 8407 (Temperature probe); 8408 (Temperature probe); 9154 (Carrying case).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Industrial handheld TRMS multimeter 50,000 counts

KEW 1061

KEW 1051

KEW 1052

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | KEW_1062 |
| Manufacturer | Kyoritsu |
Handheld Multimeters
True RMS handheld multimeter 6000 counts with K-type temperature · Ref. : KEW_1051
Price on request
Handheld Multimeters
Handheld 2-channel 10 MHz oscilloscope, multimeter and DDS generator · Ref. : 2C23T
Price on request
Handheld Multimeters
Optical multimeter with 800nm-1700nm power meter and 650nm VFL
Price on request
Handheld Multimeters
6000-Count Digital Multimeter with NCV Detection · Ref. : NF-628
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details