KEW_2200
1000 A AC clamp meter with DMM functions and continuity buzzer

- Conductor size
- φ 33mm max.
- Continuity buzzer
- Buzzer sounds below 50±30&Omega
- Dimension
- 190(L) × 68(W) × 20(D)mm
- Weight
- Approx. 120g (including batteries)
1000 A AC clamp meter with DMM functions and continuity buzzer
The Kyoritsu KEW 2200 is a slim handheld clamp meter measuring AC current up to 1000 A, with DMM functions for ACV, DCV, resistance and a continuity buzzer.
Kyoritsu KEW 2200 clamp meter. The Kyoritsu KEW 2200 is a handheld digital clamp meter with DMM functions, designed for AC current measurement as well as voltage and resistance measurement.
Main characteristics. Tear-drop shaped jaws with a 33 mm maximum conductor size, minimum resolution of 0.01 A, dimensions of 190 × 68 × 20 mm and a weight of approximately 120 g including batteries.
Measurements. AC current of 40.00 / 400.0 / 1000 A with auto-ranging, accuracy ±1.4% of reading ±6 digits (50/60 Hz) and ±1.6% ±6 digits (45 to 65 Hz). AC voltage of 4.000 / 40.00 / 400.0 / 600 V with auto-ranging. DC voltage from 400.0 mV to 600 V with auto-ranging. Resistance from 400.0 Ω to 40.00 MΩ with auto-ranging, with a continuity buzzer sounding below 50 ±30 Ω.
Power source. Two R03 (AAA) 1.5 V batteries, continuous measuring time of approximately 350 hours, auto power off after approximately 10 minutes.
Standards and safety. Compliant with IEC 61010-1 CAT III 600 V, pollution degree 2 for AC current, CAT III 300 V / CAT II 600 V for voltage, as well as IEC 61010-031, IEC 61010-2-032 and IEC 61326 (EMC).
Supplied with. Test leads 7107A, carrying case 9160, two R03 batteries and instruction manual. Manuals are available in several languages, including French.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for KEW_2200, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC (A) | 40.00/400.0/1000A (Auto-ranging); ±1.4%rdg±6dgt (50/60Hz); ±1.6%rdg±6dgt (45 to 65Hz) |
| AC V | 4.000/40.00/400.0/600V (Auto-ranging); ±1.8%rdg±7dgt (45 to 65Hz); ±2.3%rdg±8dgt (65 to 500Hz) |
| Accessories | 7107A (Test leads),; 9160 (Carrying case),; R03 (AAA) × 2, Instruction Manual |
| Applicable Standards | IEC 61010-1 CAT III 600V Pollution degree 2 (AC A),; CAT III 300V / CAT II 600V Pollution degree 2 (AC/DC V); IEC 61010-031, IEC 61010-2-032, IEC 61326 (EMC) |
| Conductor size | φ 33mm max. |
| Continuity buzzer | Buzzer sounds below 50±30&Omega |
| DC V | 400.0mV/4.000/40.00/400.0/600V (Auto-ranging); ±1.0%rdg±3dgt (*1) |
| Dimension | 190(L) × 68(W) × 20(D)mm |
| &Omega | 400.0Ω /4.000/40.00/400.0kΩ /4.000/40.00MΩ (Auto-ranging); ±2.0%rdg±4dgt (0 to 400kΩ ); ±4.0%rdg±4dgt (4MΩ ); ±8.0%rdg±4dgt (40MΩ ) |
| Power Source | R03/LR03 (AAA) (1.5V) × 2; *continuous measuring time:; Approx. 350 hours (Auto power off: Approx. 10 minutes) |
| Product Catalog | KEW 2200 Product Catalog (English)(1.75 MB) |
| Weight | Approx. 120g (including batteries) |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for KEW_2200. For a missing document or a specific revision, our experts send it to you.
The Kyoritsu KEW 2200 is a slim handheld clamp meter measuring AC current up to 1000 A, with DMM functions for ACV, DCV, resistance and a continuity buzzer.
| Parameter | Value |
|---|---|
| AC (A) | 40.00/400.0/1000A (Auto-ranging); ±1.4%rdg±6dgt (50/60Hz); ±1.6%rdg±6dgt (45 to 65Hz) |
| AC V | 4.000/40.00/400.0/600V (Auto-ranging); ±1.8%rdg±7dgt (45 to 65Hz); ±2.3%rdg±8dgt (65 to 500Hz) |
| Accessories | 7107A (Test leads),; 9160 (Carrying case),; R03 (AAA) × 2, Instruction Manual |
| Applicable Standards | IEC 61010-1 CAT III 600V Pollution degree 2 (AC A),; CAT III 300V / CAT II 600V Pollution degree 2 (AC/DC V); IEC 61010-031, IEC 61010-2-032, IEC 61326 (EMC) |
| Conductor size | φ 33mm max. |
| Continuity buzzer | Buzzer sounds below 50±30&Omega |
| DC V | 400.0mV/4.000/40.00/400.0/600V (Auto-ranging); ±1.0%rdg±3dgt (*1) |
| Dimension | 190(L) × 68(W) × 20(D)mm |
| &Omega | 400.0Ω /4.000/40.00/400.0kΩ /4.000/40.00MΩ (Auto-ranging); ±2.0%rdg±4dgt (0 to 400kΩ ); ±4.0%rdg±4dgt (4MΩ ); ±8.0%rdg±4dgt (40MΩ ) |
| Power Source | R03/LR03 (AAA) (1.5V) × 2; *continuous measuring time:; Approx. 350 hours (Auto power off: Approx. 10 minutes) |
| Product Catalog | KEW 2200 Product Catalog (English)(1.75 MB) |
| Weight | Approx. 120g (including batteries) |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
1000 A AC clamp meter with DMM functions and continuity buzzer

KEW 2200R

KEW 2007R

KEW 2117R

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | KEW_2200 |
| Manufacturer | Kyoritsu |
Clamp Meters
AC clamp sensor for digital multimeter · Ref. : KEW_8161
Price on request
Clamp Meters
2-Phase Clamp Voltammeter with Phase Diagram Display · Ref. : UT265B