KEW 8178 – AC clamp meter with 500 mV output for KEW 5050 leakage

AC clamp meter with 500 mV output for KEW 5050 leakage

Clamp Meters

  • 500mV AC/10A AC
  • Approx. 3m
  • Ø 68mm
  • MINI DIN 6PIN
Manufacturer part number
KEW_8178
Manufacturer
Kyoritsu
Rated Current
10A (rms) AC (14.1Apeak)
Output voltage
500mV AC/10A AC

The Kyoritsu KEW 8178 is an AC clamp meter with 500 mV output for measuring alternating current up to 10 A, notably in combination with the KEW 5050 leakage clamp.

Product overview

Overview. The Kyoritsu KEW 8178 is an AC clamp meter with a 500 mV analogue output, designed to measure alternating current up to 10 A (rms) on a conductor of 68 mm diameter.

Main characteristics. The rated current is 10 A rms AC (14.1 A peak). Accuracy is ±1.0% of reading ±0.025 mV between 40 and 70 Hz, and ±4.0% of reading ±0.025 mV between 30 Hz and 5 kHz for inputs of 100 mA or more. The output voltage is 500 mV AC for 10 A AC.

Interfaces and connectivity. The output uses a MINI DIN 6-pin connector, with an output impedance of approximately 60 Ω or less. The cable is approximately 3 m long.

Power and environment. The clamp operates between -10 and 50 °C, at a relative humidity of 85% or less, without condensation. Its dimensions are 186 × 129 × 53 mm and its weight is approximately 560 g.

Typical use. Combined with the KEW 5050 leakage clamp, it allows the phase shift, within 1.0° between 45 and 70 Hz, to be checked when measuring leakage currents from 10% of the KEW 5050 range.

Standards and supply. Compliant with IEC 61010-1, IEC 61010-2-032 (CAT III 300 V, pollution degree 2) and IEC 61326-1. Supplied with model 9094 carrying case and instruction manual.

See all specifications

Highlights

  • Output voltage: 500mV AC/10A AC
  • Accessories: 9094 (Carrying case), Instruction manual
  • Cable Length: Approx. 3m
  • Dimension: 186(L) × 129(W) × 53(D)mm
  • Operating temperature and humidity range: -10 to 50°C, relative humidity 85% or less (no condensation)
  • Output Connector:: MINI DIN 6PIN

Good to know before integrating

  • Thermal: rated operating range -10 to 50°C, relative humidity 85% or less (no condensation) — check it against the installation environment.