Kyoritsu KEW 4106. The Kyoritsu KEW 4106 is an earth resistance and resistivity tester designed for checking earthing installations. Main characteristics — Six earth resistance ranges covering 0.001 Ω to 200 kΩ, with earth resistivity ρ calculated automatically after the spacing between auxiliary earth spikes is set (Wenner method). Automatic or manual selection of the test current frequency in four bands of 94, 105, 111 and 128 Hz. Advanced filtering based on a Fast Fourier Transform (FFT) reduces noise interference for stable measurements. Memory for up to 800 results, transferable to a PC through the USB adapter model 8212-USB and the KEW Report software. Series interference voltage (earth voltage, AC) measurement from 0 to 50.9 Vrms. Interfaces and connectivity — Optical communication interface via the 8212-USB adapter for data transfer. Dot-matrix monochrome LCD, 192 × 64 pixels. Power and environment — Powered by 8 AA manganese dry batteries (R6), 12 V DC, with automatic power off after approximately 5 minutes. Overload protection of AC 280 V for 10 seconds between the E-S(P) and E-H(C) terminals. Enclosure rated IP54 under IEC 60529, dimensions 167 × 185 × 89 mm, weight approximately 900 g including batteries. Standards — IEC 61010-1 CAT III 300 V / CAT IV 150 V, pollution degree 2, IEC 61010-031, IEC 61557-1 and 5, IEC 61326-1 (EMC). Typical uses — Checking the resistance of earth electrodes and earthing installations, and characterising soil resistivity. Supplied accessories — Test leads 7229A and 7238A, auxiliary earth spike sets 8032, cord reels 8200-04, USB adapter 8212-USB, fuse 8923, shoulder strap 9121 and carrying case 9125.
Earth resistance: Fall-of-potential method; (currents and voltages measured via the Probes); Measurement method of Earth Resistivity (ρ ): Wenner 4-pole method; Series interference voltage (earth voltage); RMS Rectifier (between the E-S Terminals)
Memory Capacity
800 data
Over-range indication
"OL"
Overload Protection
between E-S(P) and between E-H(C) terminals AC280V / 10 sec.
Earth resistance: Fall-of-potential method; (currents and voltages measured via the Probes); Measurement method of Earth Resistivity (ρ ): Wenner 4-pole method; Series interference voltage (earth voltage); RMS Rectifier (between the E-S Terminals)
Memory Capacity
800 data
Over-range indication
"OL"
Overload Protection
between E-S(P) and between E-H(C) terminals AC280V / 10 sec.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details