KEW_8129
Flexible air-core AC current probe up to 3000 A

- Rated Current
- 300/1000/3000A
- Accuracy
- ±1.0%rdg (45 - 65Hz)
- Conductor size
- max.Ø 150mm
- Output Connector:
- MINI DIN 6PIN
Flexible air-core AC current probe up to 3000 A
The Kyoritsu KEW 8129 flexible current probe measures AC current up to 3000 A thanks to its air-core coil.
Kyoritsu KEW 8129, flexible current probe (air-core coil sensor) for AC current measurement up to 3000 A. — Main characteristics: flexible and light sensor thanks to the air-core coil, designed for various test fields, with a measurable conductor size of maximum Ø150 mm. Measuring ranges: 300 A (output 1.67 mV/A), 1000 A (output 0.5 mV/A) and 3000 A (output 0.167 mV/A), with an accuracy of ±1.0% of reading between 45 and 65 Hz and a phase shift within ±1°.
Output and connectivity. Mini DIN 6-pin output connector, output impedance of 100 Ω or less. Sensor cable approximately 2 m, output cable approximately 1 m.
Power and environment. Operating temperature 0 to 50 °C, relative humidity 85% or less with no condensation. Dimensions 111 x 61 x 43 mm excluding protrusions. Weight approximately 410 g for the 1-channel version, 680 g for the 2-channel version and 950 g for the 3-channel version.
Safety and standards. Compliant with IEC 61010-1 and IEC 61010-2-032, CAT III 600 V, pollution degree 2, and with the EMC standard IEC 61326.
Supply. Supplied according to the version (1, 2 or 3 channels) with instruction manual, 7199 output cable per channel and 9137 carrying case. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for KEW_8129, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Output voltage | 300A Range : AC500mV/AC300A (1.67mV/A) 1000A Range : AC500mV/AC1000A (0.5mV/A) 3000A Range : AC500mV/AC3000A (0.167mV/A) |
| Accessories | 8129-01 (for 1ch) Instruction Manual, 7199 (Output Cable) x1, 9137 (Carrying Case) 8129-02 (for 2ch) Instruction Manual, 7199 (Output Cable) x2, 9137 (Carrying Case) 8129-03 (for 3ch)Instruction Manual, 7199 (Output Cable) x3, 9137 (Carrying Case) |
| Accuracy | ±1.0%rdg (45 - 65Hz) |
| Applicable Standards | IEC 61010-1, IEC 61010-2-032 CAT III 600V Pollution degree2, IEC 61326 |
| Cable Length | Sensor part : approx. 2m Output cable : approx. 1m |
| Conductor size | max.Ø 150mm |
| Dimension | 111(L) x 61(W) x 43(D) mm (except for protrusions) |
| Operating temperature and humidity range | 0 - 50º C, relative humidity 85% or less (no condensation) |
| Output Connector: | MINI DIN 6PIN |
| Output Impedance | 100Ω or less |
| Phase shift | within ±1° |
| Rated Current | 300/1000/3000A |
| Weight | 8129-01 (for 1ch) Approx. 410g 8129-02 (for 2ch) Approx. 680g 8129-03 (for 3ch) Approx. 950g |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for KEW_8129. For a missing document or a specific revision, our experts send it to you.
The Kyoritsu KEW 8129 flexible current probe measures AC current up to 3000 A thanks to its air-core coil.
| Parameter | Value |
|---|---|
| Output voltage | 300A Range : AC500mV/AC300A (1.67mV/A) 1000A Range : AC500mV/AC1000A (0.5mV/A) 3000A Range : AC500mV/AC3000A (0.167mV/A) |
| Accessories | 8129-01 (for 1ch) Instruction Manual, 7199 (Output Cable) x1, 9137 (Carrying Case) 8129-02 (for 2ch) Instruction Manual, 7199 (Output Cable) x2, 9137 (Carrying Case) 8129-03 (for 3ch)Instruction Manual, 7199 (Output Cable) x3, 9137 (Carrying Case) |
| Accuracy | ±1.0%rdg (45 - 65Hz) |
| Applicable Standards | IEC 61010-1, IEC 61010-2-032 CAT III 600V Pollution degree2, IEC 61326 |
| Cable Length | Sensor part : approx. 2m Output cable : approx. 1m |
| Conductor size | max.Ø 150mm |
| Dimension | 111(L) x 61(W) x 43(D) mm (except for protrusions) |
| Operating temperature and humidity range | 0 - 50º C, relative humidity 85% or less (no condensation) |
| Output Connector: | MINI DIN 6PIN |
| Output Impedance | 100Ω or less |
| Phase shift | within ±1° |
| Rated Current | 300/1000/3000A |
| Weight | 8129-01 (for 1ch) Approx. 410g 8129-02 (for 2ch) Approx. 680g 8129-03 (for 3ch) Approx. 950g |
Answers to the questions that the recorded characteristics of KEW_8129 can answer. A question is not asked when nothing is recorded to answer it.
0 - 50º C, relative humidity 85% or less (no condensation) (source: Operating temperature and humidity range).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Flexible air-core AC current probe up to 3000 A

MODEL

MODEL 8004

MODEL 8006

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | KEW_8129 |
| Manufacturer | Kyoritsu |
Current Probes
Rogowski AC Current Probe, Flexible Coil · Ref. : RCP500
Price on request
Current Probes
Multi-tran current transformer adaptor for clamp meters · Ref. : MODEL_8004
Price on request
Current Probes
AC clamp adaptor for currents up to 1500 A · Ref. : MODEL_8006
Price on request
Current Probes
AC current transformer adaptor for clamp meters, 3000 A · Ref. : MODEL_8008
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details