RCP500 – Rogowski AC Current Probe, Flexible Coil

Rogowski AC Current Probe, Flexible Coil

Current Probes

  • -20-70℃
  • 200mApk-500Apk
  • Universal BNC
  • -30℃-70℃
Manufacturer part number
RCP500
Manufacturer
Micsig
Operating Temperature
-20-70℃
Current Range
200mApk-500Apk

The Micsig RCP500 Rogowski current probe measures AC currents from 200 mApk to 500 Apk with a 15 to 300 kHz bandwidth, without load or electrical contact with the conductor.

Product overview

Overview. The Micsig RCP500 Rogowski AC current probe is a flexible-coil current probe for measuring alternating currents on an oscilloscope. Its Rogowski coil has an inner diameter of 50 mm and a thickness of approximately 6 mm and wraps around the conductor under test.

Main characteristics. The current range runs from 200 mApk to 500 Apk, with an output sensitivity of 10 mV/A and a typical accuracy of 1%. The analogue bandwidth is 15 to 300 kHz (-3 dB), and the phase accuracy is within 0.8° between 45 Hz and 66 Hz. The conductor under test may have a diameter up to 50 mm, with positional accuracy within ±1% of the centre.

Interfaces and power. The output uses a universal BNC connector, available as powered BNC or external BNC. The coil-to-integrator cable is 2 m long, customisable. The integrator, measuring 37 × 22 × 82 mm, is powered directly by the Micsig UPI interface, or by a 5 V DC supply for oscilloscopes without UPI.

Environment and safety. The probe is designed for indoor use, pollution degree 2, up to 2000 m altitude. Its operating temperature range is -20 to 70 °C, with storage from -30 to 70 °C, and a maximum humidity of 80% without condensation. The coil withstands a maximum voltage of 10 kV RMS for 1 minute at 50 Hz or 60 Hz.

Typical uses. This probe suits AC current measurement on an oscilloscope, for example analysing power or control signals without inserting it into the circuit. Its flexible, slender form makes it practical on conductors with restricted access.

See all specifications

Highlights

  • Analog bandwidth: 15-300KHz (-3dB)
  • Coil to Integrator Cable Length: 2m (customizable)
  • Conductor Positional Accuracy: Within ±1% (Deviation from the Center)
  • Conductor Under Test Diameter: ≤Φ50mm
  • Current Range: 200mApk-500Apk
  • Influence of External Magnetic Fields: 1.5% f.s. or below (400A/m,50Hz/60Hz)

Good to know before integrating

  • Thermal: rated operating range -20-70℃ — check it against the installation environment.