MODEL_2002PA
AC clamp meter 2000 A with voltage measurement

- Frequency response
- 40Hz to 1kHz
- Conductor size
- φ 55mm max.
- Continuity buzzer
- Buzzer sounds below 50±35&Omega
- DC V
- 40/400/1000V; ±1%rdg±2dgt
AC clamp meter 2000 A with voltage measurement
The Kyoritsu MODEL 2002PA clamp meter measures AC current up to 2000 A as well as DC and AC voltages, with 55 mm diameter jaws.
Overview. The Kyoritsu MODEL 2002PA is a clamp meter for measuring AC current up to 2000 A. It is available on quotation from Atlas Electronics.
Main characteristics. AC current ranges of 400 A (0 to 400 A, ±1% rdg ±3 dgt at 50/60 Hz) and 2000 A (0 to 1500 A, ±1% rdg ±3 dgt at 50/60 Hz; 1500 to 2000 A, ±3.0% rdg at 50/60 Hz). AC voltage ranges of 40/400/750 V and DC voltage ranges of 40/400/1000 V, resistance of 400 Ω/4/40/400 kΩ, continuity buzzer sounding below 50 ±35 Ω. Peak hold function and tear drop shaped jaws of 55 mm maximum diameter.
Outputs and power. Recorder output of DC 400 mV against AC 400 A and DC 200 mV against AC 2000 A. Powered by two R6 (AA) 1.5 V batteries.
Safety and dimensions. Compliant with IEC 61010-1 CAT III 600V / CAT II 1000V, IEC 61010-2-031 and IEC 61010-2-032. Dimensions 247 × 105 × 49 mm, weight approximately 470 g.
Accessories. Test leads 7107A, carrying case 9094 and instruction manual. Output cord 7256 available as an option.
Typical uses. Measuring high AC currents on electrical installations without interrupting the circuit, thanks to the clamp jaws.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MODEL_2002PA, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC (A) | 400A (0 to 400A); ±1%rdg±3dgt[50/60Hz]; ±2%rdg±3dgt[40Hz to 1kHz]; 2000A(0 to 1500A); ±1%rdg±3dgt[50/60Hz]; ±3%rdg±3dgt[40Hz to 1kHz]; 2000A (1500 to 2000A); ±3.0%rdg [50/60Hz] |
| AC V | 40/400/750V; ±1%rdg±2dgt [50/60Hz]; ±1.5%rdg±3dgt [40Hz to 1kHz] |
| Accessories | 7107A (Test leads); 9094 (Carrying Case); R6 (AA) × 2 Instruction Manual |
| Conductor size | φ 55mm max. |
| Continuity buzzer | Buzzer sounds below 50±35&Omega |
| DC V | 40/400/1000V; ±1%rdg±2dgt |
| Dimension | 247(L) × 105(W) × 49(D)mm |
| Frequency response | 40Hz to 1kHz |
| &Omega | 400Ω /4/40/400kΩ ±1.5%rdg±2dgt |
| Optional Accessories | 7256 (Output cord) |
| Output | Recorder :; DC400mV against AC400A; DC200mV against AC2000A |
| Power Source | R6 (AA) (1.5V) × 2 |
| Product Catalog | MODEL 2002PA Product Catalog (English)(1.76 MB) |
| Safety Standard | IEC 61010-1 CAT III 600V / CAT II 1000V; IEC 61010-2-031 IEC 61010-2-032 |
| Weight | Approx. 470g |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for MODEL_2002PA. For a missing document or a specific revision, our experts send it to you.
The Kyoritsu MODEL 2002PA clamp meter measures AC current up to 2000 A as well as DC and AC voltages, with 55 mm diameter jaws.
| Parameter | Value |
|---|---|
| AC (A) | 400A (0 to 400A); ±1%rdg±3dgt[50/60Hz]; ±2%rdg±3dgt[40Hz to 1kHz]; 2000A(0 to 1500A); ±1%rdg±3dgt[50/60Hz]; ±3%rdg±3dgt[40Hz to 1kHz]; 2000A (1500 to 2000A); ±3.0%rdg [50/60Hz] |
| AC V | 40/400/750V; ±1%rdg±2dgt [50/60Hz]; ±1.5%rdg±3dgt [40Hz to 1kHz] |
| Accessories | 7107A (Test leads); 9094 (Carrying Case); R6 (AA) × 2 Instruction Manual |
| Conductor size | φ 55mm max. |
| Continuity buzzer | Buzzer sounds below 50±35&Omega |
| DC V | 40/400/1000V; ±1%rdg±2dgt |
| Dimension | 247(L) × 105(W) × 49(D)mm |
| Frequency response | 40Hz to 1kHz |
| &Omega | 400Ω /4/40/400kΩ ±1.5%rdg±2dgt |
| Optional Accessories | 7256 (Output cord) |
| Output | Recorder :; DC400mV against AC400A; DC200mV against AC2000A |
| Power Source | R6 (AA) (1.5V) × 2 |
| Product Catalog | MODEL 2002PA Product Catalog (English)(1.76 MB) |
| Safety Standard | IEC 61010-1 CAT III 600V / CAT II 1000V; IEC 61010-2-031 IEC 61010-2-032 |
| Weight | Approx. 470g |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
AC clamp meter 2000 A with voltage measurement

KEW 2003A

KEW 2009R

KT 200

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MODEL_2002PA |
| Manufacturer | Kyoritsu |
Clamp Meters
AC clamp sensor for digital multimeter · Ref. : KEW_8161
Price on request
Clamp Meters
2-Phase Clamp Voltammeter with Phase Diagram Display · Ref. : UT265B
Price on request
Clamp Meters
AC DC Clamp Digital Multimeter 750 V 600 A · Ref. : DMC-100
Price on request
Clamp Meters
AC clamp meter with 500 mV output for KEW 5050 leakage · Ref. : KEW_8178
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details